Page 1 - Service Manual

SPARC Enterprise M4000/M5000 ServersService ManualPart No.: 819-2210-14,Manual Code: C120-E352-07ENDecember 2010, Revision A

Page 2

x SPARC Enterprise M4000/M5000 Servers Service Manual • December 20107.1.4 Securing the Server 7–58. I/O Unit Replacement 8–18.1 PCI Cassette Replacem

Page 3

6-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.1.8 Securing the Server1. Install the fan cover.This step includes replacing

Page 4

Chapter 6 Storage Devices Replacement 6-96.1.9 Accessing the Hard Disk Drive Backplane of theM5000 ServerCaution – There is an electrical hazard if th

Page 5 - Contents

6-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.1.10 Removing the Hard Disk Drive Backplane of theM5000 ServerNote – The fan

Page 6

Chapter 6 Storage Devices Replacement 6-116.1.12 Securing the ServerCaution – The motherboard unit is heavy. Two people are recommended to lift theuni

Page 7 - Contents vii

6-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.2 CD-RW/DVD-RW Drive Unit (DVDU)ReplacementThe CD-RW/DVD-RW drive unit and C

Page 8

Chapter 6 Storage Devices Replacement 6-13FIGURE 6-4 shows the location of the CD-RW/DVD-RW drive unit andCD-RW/DVD-RW backplane on the M4000server.FI

Page 9 - Contents ix

6-14 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 6-5 shows the location of the CD-RW/DVD-RW drive unit andCD-RW/DVD-RW b

Page 10

Chapter 6 Storage Devices Replacement 6-156.2.1 Identifying the Type of CD-RW/DVD-RW DriveUnitThere are two types of CD-RW/DVD-RW drive units: tray lo

Page 11 - Contents xi

6-16 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.2.2 Accessing the CD-RW/DVD-RW Drive Unit● Power off the server.This step in

Page 12

Chapter 6 Storage Devices Replacement 6-176.2.4 Installing the CD-RW/DVD-RW Drive UnitCaution – Do not force the CD-RW/DVD-RW Drive Unit into the slot

Page 13 - Contents xiii

Contents xi9.1 XSCF Unit Replacement 9–19.1.1 Accessing the XSCF Unit 9–39.1.2 Removing the XSCF Unit 9–49.1.3 Installing the XSCF Unit 9–59.1.4 Secur

Page 14

6-18 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.2.6 Accessing the CD-RW/DVD-RW Drive Backplaneof the M4000 ServerCaution – T

Page 15 - Contents xv

Chapter 6 Storage Devices Replacement 6-193. Loosen the captive screw that holds the rear of the CD-RW/DVD-RW DriveBackplane in place.The CD-RW/DVD-RW

Page 16 - Index Index–1

6-20 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010Note – If the Oracle Solaris automatic booting is set, use the sendbreak -ddom

Page 17

Chapter 6 Storage Devices Replacement 6-21Caution – The motherboard unit is heavy. Two people are recommended to lift theunit. If the unit is too heav

Page 18 - Servers Documentation

6-22 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20103. Connect the power and serial cables to the rear of the CD-RW/DVD-RW DriveBa

Page 19 - Text Conventions

Chapter 6 Storage Devices Replacement 6-236.3 Tape Drive Unit ReplacementThe tape drive unit is an active, hot, or cold replacement component. The tap

Page 20 - Documentation Feedback

6-24 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 6-8 shows the location of the tape drive unit and tape drive backplane(

Page 21 - Safety and Tools

Chapter 6 Storage Devices Replacement 6-25FIGURE 6-9 shows the location of the tape drive unit and tape drive backplane(TAPEBP) on the M5000server.FIG

Page 22 - 1.2 System Precautions

6-26 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.3.1 Accessing the Tape Drive Unit● Remove the tape drive unit from the domai

Page 23 - 1.2.4 Handling Components

Chapter 6 Storage Devices Replacement 6-276.3.3 Installing the Tape Drive UnitCaution – Do not force the tape drive unit into the slot. Doing so can c

Page 24

xii SPARC Enterprise M4000/M5000 Servers Service Manual • December 201011. Memory Board Replacement 11–111.1 Memory Board Replacement 11–111.1.1 Acces

Page 25 - Fault Isolation

6-28 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.3.5 Accessing the Tape Drive Backplane of the M4000ServerCaution – There is

Page 26 - Diagnostic Method Flow Chart

Chapter 6 Storage Devices Replacement 6-296.3.6 Removing the Tape Drive Backplane of the M4000Server1. Remove the CD-RW/DVD-RW Drive Backplane.This st

Page 27 - Chapter 2 Fault Isolation 2-3

6-30 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.3.8 Securing the Server1. Install the 60-mm fan backplane.This step includes

Page 28 - Configuration

Chapter 6 Storage Devices Replacement 6-316.3.9 Accessing the Tape Drive Backplane of the M5000ServerCaution – There is an electrical hazard if the po

Page 29 - XSCF> showhardconf

6-32 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.3.10 Removing the Tape Drive Backplane of the M5000ServerNote – The fan unit

Page 30

Chapter 6 Storage Devices Replacement 6-336.3.12 Securing the ServerCaution – The motherboard unit is heavy. Two people are recommended to lift theuni

Page 31 - XSCF> version(8)

6-34 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

Page 32 - 2.3 Operator Panel

7-1CHAPTER7Power Systems ReplacementThis chapter describes the power supply units and how to remove and replace them.This information is organized int

Page 33 - M4000 Server Operator Panel

7-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 7-1 shows the locations of the power supply unit on the M4000 server.FIG

Page 34 - M5000 Server Operator Panel

Chapter 7 Power Systems Replacement 7-3FIGURE 7-2 shows the locations of the power supply units on the M5000 server.FIGURE 7-2 M5000 Server Power Supp

Page 35 - TABLE 2-3

Contents xiii▼ Adding a SPARC64 VII/SPARC64 VII+ CPU Module to a DomainConfigured WithSPARC64 VI 12-1312.2.3 Upgrading a SPARC64 VI CPU Module to SPAR

Page 36 - TABLE 2-4

7-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20107.1.1 Accessing the Power Supply Unit● From the XSCF Shell prompt, use the repl

Page 37 - Switches (Operator Panel)

Chapter 7 Power Systems Replacement 7-5FIGURE 7-3 Removing the Power Supply Unit7.1.3 Installing the Power Supply UnitCaution – Do not force the power

Page 38 - 2.4 Error Conditions

7-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

Page 39 - ■ Diagnoses the problems

8-1CHAPTER8I/O Unit ReplacementThis chapter describes how to remove and install the I/O unit and PCI cassettes. Theinformation is organized into the f

Page 40 - Output Displayed Description

8-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 8-1 shows the I/O unit location on the M4000 server.FIGURE 8-1 M4000 Ser

Page 41 - 2.4.3 Messaging Output

Chapter 8 I/O Unit Replacement 8-3FIGURE 8-2 shows the I/O unit locations on the M5000 server.FIGURE 8-2 M5000 I/O Unit Locations (Rear)Location Numbe

Page 42 - 2.5 LED Functions

8-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20108.1 PCI Cassette ReplacementPCI cassettes are hot, active, or cold replacement

Page 43 - Component LED Descriptions

Chapter 8 I/O Unit Replacement 8-5Note – Do not install an I/O Box link card (or any PCIe card sensitive to timingdelays) in the slot marked PCI casse

Page 44

8-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20103. Remove the PCI cassette from the slot and place it on the ESD mat.Note – Whe

Page 45

Chapter 8 I/O Unit Replacement 8-7Note – When you insert the PCI cassette using hot-swap, the cassette isautomatically powered on and configured. Chec

Page 46 - 2.6.2.1 fmdump -V Command

xiv SPARC Enterprise M4000/M5000 Servers Service Manual • December 201014.1 Backplane Unit Replacement 14–114.1.1 Accessing the M4000 Server Backplane

Page 47 - 2.6.3.1 fmadm repair Command

8-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 8-5 PCI Card Mounted in PCI Cassette8.2.2 Installing the PCI Card1. Loos

Page 48 - 2.6.3.2 fmadm config Command

Chapter 8 I/O Unit Replacement 8-9FIGURE 8-6 Sequence of Adjusting the PCI Card in PositionNote – The adjustable stops should be snug against the card

Page 49 - Commands

8-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20108.3 I/O Unit ReplacementThe I/O units are cold replacement components.8.3.1 Ac

Page 50 - 2.7.1.1 Options

Chapter 8 I/O Unit Replacement 8-114. Using a No. 1 screwdriver, press the lock button on the left side of the I/O unitto free the unit release lever

Page 51 - 2.7.2.1 Options

8-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20108.3.4 Securing the Server1. Power on the server.This step includes reconnectin

Page 52

Chapter 8 I/O Unit Replacement 8-13FIGURE 8-8 I/O Unit DC-DC Converter, DC-DC Converter Connector, and DC-DC Converter Riser LocationLocation Number C

Page 53

8-14 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20108.4.1 Accessing the I/O Unit DC-DC Converter(DDC_A#0 or DDC_B#0)Caution – Ther

Page 54 - 2.7.3.1 Options

Chapter 8 I/O Unit Replacement 8-15FIGURE 8-9 Exposing the I/O Unit DC-DC Converter (Without a DC-DC Converter Retainer)3. Loosen the three screws tha

Page 55 - The prtconf output continued

8-16 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010 If your server does not have a label covering part of the I/O unit DC-DCconv

Page 56

Chapter 8 I/O Unit Replacement 8-17Note – Do not pull the retention clips of the DC-DC converter retainer too far outwhen disengaging the DC-DC conver

Page 57 - 2.7.4.1 Options

Contents xvC.5 Power C–7C.6 FAN Module C–8C.7 eXtended System Control Facility Unit C–9C.8 Drives C–10C.8.1 Hard Disk Drive C–10C.8.2 CD-RW/DVD-RW Dri

Page 58 - 2.7.5 Using the ping Command

8-18 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010 If your server does have a label covering part of the I/O unit DC-DC convert

Page 59 - 2.7.6 Using the ps Command

Chapter 8 I/O Unit Replacement 8-19FIGURE 8-12 Installing the DC-DC Converter (Without a DC-DC Converter Retainer)

Page 60 - 2.7.7.1 Options

8-20 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 8-13 Installing the DC-DC Converter (With a DC-DC Converter Retainer)4.

Page 61 - 2.8 Other Issues

Chapter 8 I/O Unit Replacement 8-218.4.4 Securing the Server1. Install the I/O unit.This step includes installing the I/O unit, restoring the cable ma

Page 62

8-22 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20108.4.6 Removing the I/O Unit DC-DC Converter Riser1. Loosen the two screws at t

Page 63 - Periodic Maintenance

Chapter 8 I/O Unit Replacement 8-23FIGURE 8-14 Removing the I/O Unit DC-DC Converter Riser and DC-DC Converter (DDC_B#0)

Page 64

8-24 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20108.4.7 Replacing the I/O Unit DC-DC Converter RiserCaution – The DC-DC converte

Page 65 - FRU Replacement Preparation

Chapter 8 I/O Unit Replacement 8-25Note – If the Oracle Solaris automatic booting is set, use the sendbreak -ddomain_id command after the display cons

Page 66 - FRU Replacement Information

8-26 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

Page 67 - TABLE 4-1

9-1CHAPTER9XSCF Unit ReplacementThe eXtended System Control facility unit (XSCFU or XSCF unit) is also known asthe service processor. The unit operate

Page 68 - 4.2 Active Replacement

xvi SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010F.3.1 Removing the Air Filter from the M5000 Server F–13F.3.2 Servicing the Air

Page 69

9-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 9-1 shows the XSCF unit location on the M4000 server.FIGURE 9-1 M4000 Se

Page 70 - 4.3 Hot Replacement

Chapter 9 XSCF Unit Replacement 9-3FIGURE 9-2 shows the XSCF unit location on the M5000 server.FIGURE 9-2 M5000 Server XSCF Unit Location (Rear)9.1.1

Page 71

9-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20109.1.2 Removing the XSCF UnitCaution – Use proper ESD grounding techniques when

Page 72

Chapter 9 XSCF Unit Replacement 9-59.1.3 Installing the XSCF UnitCaution – Do not force the XSCF unit into a slot. Doing so can cause damage to theXSC

Page 73 - EXAMPLE 4-3 showhardconf

9-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20103. Reset the clock.See the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Serve

Page 74 - EXAMPLE 4-4 showhardconf

10-1CHAPTER10Fan Modules ReplacementThe fan units move air currents into and out of the server. This chapter describeshow to remove and install the fa

Page 75 - TABLE 2-11 for LED status

10-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 10-1 shows the fan module and fan backplane location on the M4000 serve

Page 76 - Off and On)

Chapter 10 Fan Modules Replacement 10-3FIGURE 10-2 shows the fan module and fan backplane location on the M5000 server.FIGURE 10-2 M5000 Server Fan Mo

Page 77

10-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201010.1.1 Accessing the 60-mm Fan Module1. From the XSCF Shell prompt, use the re

Page 78

Chapter 10 Fan Modules Replacement 10-510.1.2 Removing the 60-mm Fan Module1. Place a No. 1 screwdriver into the fan release hole and pull upwards on

Page 79 - EXAMPLE 4-6 showhardconf

xviiPrefaceThis service manual describes how to service the SPARC Enterprise M4000/M5000servers from Oracle and Fujitsu. This document is intended for

Page 80 - (domain console) again:

10-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201010.1.3 Installing the 60-mm Fan ModuleCaution – Do not force the fan into the

Page 81 - EXAMPLE 4-8 show-devs

Chapter 10 Fan Modules Replacement 10-710.1.5 Accessing the 172-mm Fan Module1. From the XSCF Shell prompt, use the replacefru command to disable the

Page 82 - EXAMPLE 4-9 probe-scsi-all

10-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201010.1.6 Removing the 172-mm Fan Module1. Place a No. 1 screwdriver into the fan

Page 83 - Internal Components Access

Chapter 10 Fan Modules Replacement 10-910.1.7 Installing the 172-mm Fan ModuleCaution – Do not force the fan module into the slot. Doing so can cause

Page 84 - FIGURE 5-1)

10-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201010.1.9 Accessing the 60-mm Fan BackplaneCaution – There is an electrical haza

Page 85

Chapter 10 Fan Modules Replacement 10-1110.1.10 Removing the 60-mm Fan Backplane1. Observe how the cable bundle routes beneath the left front edge of

Page 86 - FIGURE 5-2)

10-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201010.1.11 Installing the 60-mm Fan Backplane1. Put the 60-mm fan backplane into

Page 87 - 5.2.1 Removing the Top Cover

Chapter 10 Fan Modules Replacement 10-1310.1.13 Accessing the SPARC Enterprise M4000 172-mmFan BackplaneCaution – There is an electrical hazard if the

Page 88 - FIGURE 5-4)

10-14 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20105. Slide the 172-mm fan backplane towards the interior of the server and then

Page 89

Chapter 10 Fan Modules Replacement 10-15FIGURE 10-6 Removing the M4000 Server 172-mm Fan Backplane

Page 90 - 5.3.1 Removing the Fan Cover

xviii SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010SPARC Enterprise M4000/M5000Servers DocumentationFor the web location of all

Page 91

10-16 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201010.1.15 Installing the M4000 Server 172-mm FanBackplane1. Slide the 172-mm fa

Page 92 - 5.3.2 Replacing the Fan Cover

Chapter 10 Fan Modules Replacement 10-1710.1.17 Accessing the M5000 Server 172-mm FanBackplaneCaution – There is an electrical hazard if the power cor

Page 93 - Storage Devices Replacement

10-18 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20105. Slide the 172-mm fan backplane towards the interior of the server and then

Page 94 - 3 Hard disk drive (HDD#0)

Chapter 10 Fan Modules Replacement 10-19FIGURE 10-7 Removing the M5000 Server 172-mm Fan Backplane

Page 95

10-20 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201010.1.19 Installing the M5000 Server 172-mm FanBackplane1. Slide the 172-mm fa

Page 96 - Removing the Hard Disk Drive

11-1CHAPTER11Memory Board ReplacementThe memory boards contain system memory DIMMs. This chapter describes how toremove and replace memory boards and

Page 97 - 6.1.4 Securing the Server

11-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 11-1 shows the memory board location on the M4000 server.FIGURE 11-1 M4

Page 98 - M4000 Server

Chapter 11 Memory Board Replacement 11-3FIGURE 11-2 shows the memory board location on the M5000 server.FIGURE 11-2 M5000 Server Memory Board Location

Page 99

11-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201011.1.1 Accessing the Memory BoardCaution – There is an electrical hazard if th

Page 100 - 6.1.8 Securing the Server

Chapter 11 Memory Board Replacement 11-511.1.2 Removing the Memory Board1. Pinch the handles together and pull both levers upwards simultaneously toun

Page 101 - M5000 Server

Preface xixText ConventionsThis manual uses the following fonts and symbols to express specific types ofinformation.SPARC Enterprise M4000/M5000/M8000

Page 102

11-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201011.1.3 Installing the Memory BoardCaution – Do not force the memory board into

Page 103 - 6.1.12 Securing the Server

Chapter 11 Memory Board Replacement 11-711.2 DIMM ReplacementThe DIMMs are cold FRU replacement components. The entire server must bepowered off and t

Page 104 - Replacement

11-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010Caution – To replace or install a DIMM, do not fail to confirm the DIMMinforma

Page 105 - Location Number Component

Chapter 11 Memory Board Replacement 11-9FIGURE 11-5 shows the explanation of DIMM information.FIGURE 11-5 Explanation of DIMM Information11.2.2 Memory

Page 106

11-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201011.2.3 Installing Memory: Only half or fully populated memory boards may be

Page 107 - Figure Leg end

Chapter 11 Memory Board Replacement 11-1111.2.5 Removing the DIMMs1. Open the plastic hinged DIMM cover on the memory board cover to expose theDIMMs.2

Page 108 - FIGURE 6-7)

11-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201011.2.6 Installing the DIMMs1. Push the DIMM evenly into the DIMM socket.2. Sl

Page 109 - 6.2.5 Securing the Server

12-1CHAPTER12CPU Module ReplacementThis chapter describes how to remove and replace CPU modules (CPUM) Theinformation is organized into the following

Page 110

12-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 12-1 shows the CPU module location on the M4000 server.FIGURE 12-1 M400

Page 111 - 6.2.9 Securing the Server

Chapter 12 CPU Module Replacement 12-3FIGURE 12-2 shows the CPU module location on the M5000 server.FIGURE 12-2 M5000 Server CPU Module LocationsLocat

Page 112

PleaseRecycleCopyright © 2007, 2010, Oracle and/or its affiliates. All rights reserved.FUJITSU LIMITED provided technical input and review on portions

Page 113

xx SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010Notes on SafetyRead the following documents thoroughly before using or handling

Page 114 - 6.2.13 Securing the Server

12-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201012.1.1 Accessing the CPU ModuleCaution – There is an electrical hazard if the

Page 115

Chapter 12 CPU Module Replacement 12-512.1.2 Removing the CPU Module1. Unlock the levers and raise both levers simultaneously to unseat the CPUmodule

Page 116 - (TAPEBP) on the M4000 server

12-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201012.1.3 Installing the CPU ModuleCaution – Do not force the CPU module into the

Page 117 - (TAPEBP) on the M5000

Chapter 12 CPU Module Replacement 12-712.2 CPU UpgradeThis section describes procedures for installing SPARC64 VII/SPARC64 VII+processors in M4000/M50

Page 118 - Removing the Tape Drive

12-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201012.2.1 SPARC64 VII/SPARC64 VII+ CPU ModulesAdded to a New Domain▼ Adding a SPA

Page 119 - 6.3.4 Securing the Server

Chapter 12 CPU Module Replacement 12-9Caution – After installing the CPU module, you must reconnect the power cable tothe power supply.9. Log in to th

Page 120

12-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010 Set up the CPU operational mode on the domain.Refer to Chapter 2, “Setting

Page 121

Chapter 12 CPU Module Replacement 12-1112.2.2 SPARC64 VII/SPARC64 VII+ Processors Added toan Existing DomainAdding SPARC64 VII/SPARC64 VII+ Processors

Page 122 - 6.3.8 Securing the Server

12-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20107. Collect an XSCF snapshot to archive system status prior to upgrade.If a pr

Page 123

Chapter 12 CPU Module Replacement 12-1313. Continue with the appropriate installation procedure: If you are adding a new SPARC64 VII/SPARC64 VII+ –eq

Page 124

1-1CHAPTER1Safety and ToolsThis chapter describes safety and tools information. The information is organizedinto the following topics: Section 1.1, “

Page 125 - 6.3.12 Securing the Server

12-14 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20103. Confirm that the installed CPU module is recognized by the server and that

Page 126

Chapter 12 CPU Module Replacement 12-1512.2.3 Upgrading a SPARC64 VI CPU Module toSPARC64 VII/SPARC64 VII+ on an ExistingDomainThis procedure must be

Page 127 - Power Systems Replacement

12-16 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20105. Confirm that no error has occurred.6. Change the key position on the opera

Page 128 - Power Supply Unit Locations

13-1CHAPTER13Motherboard Unit ReplacementThis chapter describes how to remove and replace the motherboard. The informationis organized into the follow

Page 129

13-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 13-1 shows the location of the motherboard unit on the M4000 server.FIG

Page 130 - XSCF> replacefru

Chapter 13 Motherboard Unit Replacement 13-3FIGURE 13-2 shows the location of the motherboard unit on the M5000 server.FIGURE 13-2 M5000 Server Mother

Page 131 - 7.1.4 Securing the Server

13-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201013.1.1 Accessing the M4000 Server Motherboard UnitCaution – There is an electr

Page 132

Chapter 13 Motherboard Unit Replacement 13-513.1.2 Removing the M4000 Server Motherboard Unit1. Push the server back into the rack.2. Loosen the two c

Page 133 - I/O Unit Replacement

13-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010Caution – The motherboard unit is a long and heavy assembly that houses thesys

Page 134 - 1 I/O unit (IOU#0)

Chapter 13 Motherboard Unit Replacement 13-7Note – If the Oracle Solaris automatic booting is set, use the sendbreak -ddomain_id command after the dis

Page 135 - 2 I/O unit (IOU#0)

1-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010Caution – Attach the cord of the antistatic wrist strap directly to the server.

Page 136 - 8.1 PCI Cassette Replacement

13-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010Note – If the motherboard unit is only being removed to provide access to theb

Page 137 - FIGURE 8-4)

Chapter 13 Motherboard Unit Replacement 13-9FIGURE 13-4 Removing the M5000 Server Motherboard Unit

Page 138 - Removing the PCI Cassette

13-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201013.1.7 Installing the M5000 Server Motherboard UnitCaution – The motherboard

Page 139 - 8.2 PCI Card Replacement

Chapter 13 Motherboard Unit Replacement 13-1113.1.8 Securing the Server1. Install the CPU modules and filler panels.See Section 12.1.3, “Installing th

Page 140 - 8.2.2 Installing the PCI Card

13-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201013.2 DC-DC Converter ReplacementThe DC-DC converters are cold replacement com

Page 141 - 1-2-3 sequence in FIGURE 8-6

Chapter 13 Motherboard Unit Replacement 13-13FIGURE 13-6 shows the location of the DC-DC converter on the M5000 server.FIGURE 13-6 M5000 Server DC-DC

Page 142 - 8.3 I/O Unit Replacement

13-14 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201013.2.1 Accessing the M4000 Server DC-DC ConverterCaution – There is an electr

Page 143 - 8.3.3 Installing the I/O Unit

Chapter 13 Motherboard Unit Replacement 13-1513.2.2 Removing the M4000 Server DC-DC Converter● Pull the DC-DC converter from the socket and place it o

Page 144 - 8.3.4 Securing the Server

13-16 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201013.2.3 Installing the M4000 Server DC-DC ConverterCaution – The converter des

Page 145 - 4 DC-DC Converter (DDC_A#0)

Chapter 13 Motherboard Unit Replacement 13-1713.2.5 Accessing the M5000 Server DC-DC ConverterCaution – There is an electrical hazard if the power cor

Page 146 - (DDC_A #0 or DDC_B #0)

Chapter 1 Safety and Tools 1-3Free-standing equipment racks should be supplied with a stabilizer feature, whichmust be sufficient to support the weigh

Page 147 - FIGURE 8-9)

13-18 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201013.2.6 Removing the M5000 Server DC-DC ConverterCaution – Use proper ESD grou

Page 148 - FIGURE 8-10)

Chapter 13 Motherboard Unit Replacement 13-19Note – If the Oracle Solaris automatic booting is set, use the sendbreak -ddomain_id command after the di

Page 149 - #0 or DDC_B #0)

13-20 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010For details on the configuration in each domain which consists of processors

Page 150 - FIGURE 8-12)

Chapter 13 Motherboard Unit Replacement 13-219. Update the XCP version.For the firmware updating procedures, see the SPARC EnterpriseM3000/M4000/M5000

Page 151

13-22 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201017. Power on all the target domain.18. Confirm that the target domain has bee

Page 152

14-1CHAPTER14Backplane Unit ReplacementThe backplane unit is composed of the power supply and I/O backplane. The SPARCEnterprise M5000 backplane unit

Page 153 - 8.4.4 Securing the Server

14-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 14-1 shows the backplane unit location on the M4000 server.FIGURE 14-1

Page 154 - FIGURE 8-14)

Chapter 14 Backplane Unit Replacement 14-3FIGURE 14-2 shows the backplane unit location on the M5000 server.FIGURE 14-2 M5000 Server Backplane Unit Lo

Page 155

14-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010Caution – Use proper ESD grounding techniques when handling components. SeeSec

Page 156 - 8.4.8 Securing the Server

Chapter 14 Backplane Unit Replacement 14-55. Remove the motherboard unit.This step includes removing the CPU modules, possibly the memory boards,disco

Page 157

1-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010 Hold the board by the handle and finger hold panels, where the board stiffene

Page 158

14-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102. Loosen the eight(8) green captive screws that hold the backplane unit inpos

Page 159 - XSCF Unit Replacement

Chapter 14 Backplane Unit Replacement 14-714.1.3 Installing the M4000 Server Backplane Unit1. Remove the ground cable and operator panel cable from th

Page 160 - M4000 server

14-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201014.1.4 Securing the Server1. Install the CD-RW/DVD-RW Drive Backplane.This ste

Page 161 - 9.1.1 Accessing the XSCF Unit

Chapter 14 Backplane Unit Replacement 14-9Note – If the Oracle Solaris automatic booting is set, use the sendbreak -ddomain_id command after the displ

Page 162 - 9.1.2 Removing the XSCF Unit

14-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20104. Remove the power supply units.See Section 7.1.2, “Removing the Power Suppl

Page 163 - 9.1.4 Securing the Server

Chapter 14 Backplane Unit Replacement 14-11FIGURE 14-4 Removing the M5000 Server Backplane

Page 164 - 3. Reset the clock

14-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201014.1.7 Installing the M5000 Server Backplane Unit1. Connect the ground cable

Page 165 - Fan Modules Replacement

Chapter 14 Backplane Unit Replacement 14-135. Install the top cover.This step includes sliding the server in to the equipment rack and restoring thean

Page 166

14-14 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

Page 167 - 4 172-mm fan module (FAN_A#2)

15-1CHAPTER15Operator Panel ReplacementThis chapter describes how to remove and install the operator panel. The informationis organized into the follo

Page 168

2-1CHAPTER2Fault IsolationThis chapter describes overview and fault diagnosis information. The information isorganized into the following topics: Sec

Page 169 - 60-mm Fan Module Removal

15-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 15-1 shows the location of the operator panel on the M4000 server.FIGUR

Page 170 - 10.1.4 Securing the Server

Chapter 15 Operator Panel Replacement 15-3FIGURE 15-2 shows the location of the operator panel on the M5000 server.FIGURE 15-2 M5000 Server Operator P

Page 171

15-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201015.2 Accessing the Operator PanelCaution – There is an electrical hazard if th

Page 172 - 172-mm Fan Module Removal

Chapter 15 Operator Panel Replacement 15-51. Pull the levers outwards and disconnect the operator panel keyswitch cable(FIGURE 15-3).2. Press the smal

Page 173 - 10.1.8 Securing the Server

15-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 15-3 Removing the Operator Panel

Page 174

Chapter 15 Operator Panel Replacement 15-715.2.2 Installing the Operator PanelCaution – Use proper ESD grounding techniques when handling components.

Page 175 - FIGURE 10-5 #3 and #4)

15-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

Page 176 - 10.1.12 Securing the Server

A-1APPENDIXAComponents ListThis appendix shows the server nomenclature and component numbering.FIGURE A-1 shows the M4000 server.

Page 177 - Fan Backplane

A-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE A-1 M4000 Server Component LocationsLocationNumber ComponentLocationNumb

Page 178

Appendix A Components List A-3FIGURE A-2 shows the M5000 server.8 Tape drive backplane (TAPEBP) 29 Memory board (MEMB#2)9 Hard disk drive backplane (H

Page 179

2-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 2-1 Diagnostic Method Flow ChartNo

Page 180 - 10.1.16 Securing the Server

A-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE A-2 M5000 Server Component Locations1541719462345687910161820212223 24 2

Page 181

Appendix A Components List A-5LocationNumber ComponentLocationNumber Component1 Top cover 32 I/O unit (IOU#1)2 CPU module (CPUM#0) 33 DC-DC Converter

Page 182

A-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 201027 Operator panel (OPNL) 58 Memory board (MEMB#4)28 I/O unit (IOU#0) 59 Memory

Page 183

B-1APPENDIXBRules for System ConfigurationThis appendix shows the system configurations for the midrange servers.B.1 Server ConfigurationTABLE B-1 sho

Page 184 - 10.1.20 Securing the Server

B-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010TABLE B-1 System FeaturesFeatures M4000 Server M5000 Server NotesMotherboard un

Page 185 - Memory Board Replacement

Appendix B Rules for System Configuration B-3I/O unit (IOU) 1 2 Each IOU contains the following:• PCI cards—Four short PCI Express (PCIe)slots (four u

Page 186 - 4 Memory board (MEMB#3)

B-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010Power supplies (2000W) 2 (1+ 1redundant)4(2+2redundant)Redundant cooling • Four

Page 187

C-1APPENDIXCFRU ListThis appendix shows the midrange server FRUs and is divided into the followingsections: Section C.1, “Server Overview” on page C-

Page 188

C-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010TABLE C-1 identifies the FRU components.Note – If the hard disk drive is the bo

Page 189 - Memory Board Removal

Appendix C FRU List C-3C.2 System BoardsC.2.1 Motherboard UnitThe motherboard unit is the main circuit board for the midrange servers. Thefollowing co

Page 190 - 11.1.4 Securing the Server

Chapter 2 Fault Isolation 2-3FIGURE 2-2 Diagnostic Method Flow Chart—Traditional Data Collection

Page 191 - 11.2 DIMM Replacement

C-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010C.2.2 CPU ModuleTABLE C-2 lists the maximum number of CPU modules that can be i

Page 192 - EXAMPLE 11-1 showhardconf

Appendix C FRU List C-5C.2.3 Memory BoardEach memory board provides a memory access controller (MAC) and eight DIMMslots. To remove or install memory

Page 193 - FIGURE 11-4)

C-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010C.3 Backplane UnitThe midrange servers contain an I/O backplane/power backplane

Page 194 - 11.2.4 Accessing the DIMMs

Appendix C FRU List C-7Refer to Section 8.3, “I/O Unit Replacement” on page 8-10 for replacementprocedures.C.5 PowerPower is provided to both midrange

Page 195 - 11.2.5 Removing the DIMMs

C-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010There are two fans in each power supply unit.The SPARC Enterprise M5000 server

Page 196 - 11.2.7 Securing the Server

Appendix C FRU List C-9Refer to Section 10.1, “Fan Module Replacement” on page 10-1 for replacementprocedures.C.7 eXtended System Control Facility Uni

Page 197 - CPU Module Replacement

C-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010C.8 DrivesBoth servers provide front-panel access to the drives. TABLE C-7 lis

Page 198 - 2 CPU module (CPUM#0)

Appendix C FRU List C-11C.8.2 CD-RW/DVD-RW Drive Unit (DVDU)There are two types of CD-RW/DVD-RW drive units: tray load or slot load. Eachtype of drive

Page 199 - 1 CPU module (CPUM#0)

C-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010The Serial Advanced Technology Attachment (SATA) interface is a serial linkbet

Page 200

D-1APPENDIXDExternal Interface SpecificationsThis appendix describes the specifications of the connectors provided on the SPARCEnterprise server unit:

Page 201 - CPU Module Removal

2-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.2 Checking the Server and SystemConfigurationBefore and after maintenance wor

Page 202 - 12.1.4 Securing the Server

D-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010D.1 Serial PortTABLE D-1 Serial PortSetting Pin No Signal Name Input/Output Des

Page 203 - 12.2 CPU Upgrade

Appendix D External Interface Specifications D-3D.2 UPC (UPS Control) PortD.3 USB PortTABLE D-2 UPC (UPS Control) PortSetting Pin No Signal Name Input

Page 204 - Added to a New Domain

D-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010D.4 Connection Diagram for Serial CableFIGURE D-1 Connection Diagram for Serial

Page 205 - ■ Set up the domain

E-1APPENDIXEUPS ControllerThis appendix explains the UPS controller (UPC) that controls the uninterruptiblepower supply (UPS) unit. Section E.1, “Ove

Page 206 - XSCF> showstatus

E-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010E.3 Signal Line ConfigurationThis section describes signal definitions and elec

Page 207 - XSCF> poweroff -a

Appendix E UPS Controller E-3TABLE E-1 UPS Interface SignalsON:Indicates contacts are closedOFF: Indicates contacts are openNote1: Use a UPS capable o

Page 208 - XSCF> version -c cmu -v

E-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010E.4.2 Output circuitE.5 UPS CableThe UPS cable specifications are as follows:

Page 209 - SPARC64 VI

Appendix E UPS Controller E-5FIGURE E-2 Corresponding Terminals in UPC Port and the UPS CableNote – If you need UPC cables, you need to make arrangeme

Page 210 - ■ Add the XSB to the domain

E-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

Page 211

F-1APPENDIXFAir FiltersThe air filters for the M4000 and M5000 servers are optional and intended for use inenvironments where additional filtering is

Page 212

Chapter 2 Fault Isolation 2-5The hardware configuration and the status of each hardware component can bechecked from the maintenance terminal using eX

Page 213 - Motherboard Unit Replacement

F-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010F.1 M4000 and M5000 Servers Air FilterThe air filter is held in place on the fr

Page 214

Appendix F Air Filters F-36. Use the showaltitude(8) command to check the setting of air filter.7. Use the rebootxscf(8) command to reset XSCF.8. Star

Page 215

F-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE F-2 Hook and Loop Tape Locations

Page 216

Appendix F Air Filters F-52. Carefully remove the tape protective backing, leaving the hook and loop tapestill attached to the filter.FIGURE F-3 Remov

Page 217 - FIGURE 13-3)

F-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20103. Carefully position the air filter to the front of the server, making sure no

Page 218 - 13.1.4 Securing the Server

Appendix F Air Filters F-74. Press firmly at all places where the sticky tape comes in contact with the bezel.The air filter is now installed.5. Retur

Page 219

F-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010F.2.1 Removing the Air Filter From the M4000 ServerThis section covers how to r

Page 220 - FIGURE 13-4)

Appendix F Air Filters F-9F.3 Air Filter Installation for the M5000ServerTest fit the filter to the front bezel of the server to make sure you know wh

Page 221

F-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20101. Locate the protective strips on the back side of the filter and clean the b

Page 222

Appendix F Air Filters F-11FIGURE F-9 Installing the Upper Air Filter to the M5000 ServerFIGURE F-10 Installing the Lower Air Filter to the M5000 Serv

Page 223 - 13.1.8 Securing the Server

Copyright © 2007, 2010, Oracle et/ou ses sociétés affiliées. Tous droits réservés.FUJITSU LIMITED a fourni et vérifié des données techniques de certaine

Page 224 - 3 DC-DC Converter (DDC_A#1)

2-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.2.2 Checking the Software and FirmwareConfigurationThe software and firmware

Page 225

F-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20104. Press firmly at all places where the sticky tape comes in contact with the

Page 226

Appendix F Air Filters F-13F.3.1 Removing the Air Filter from the M5000 ServerThis section covers how to remove the air filter for servicing power sup

Page 227 - Removing the DC-DC Converter

F-14 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010F.3.2 Servicing the Air FilterServicing the Air filter is done by removing the

Page 228 - 13.2.4 Securing the Server

Appendix F Air Filters F-1511. Perform Steps 1 through 8 of Section F.1.1, “Command Operations Procedures”on page F-2.

Page 229

F-16 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

Page 230 - 13.2.8 Securing the Server

G-1APPENDIXGAbbreviationsThis appendix lists out the proper names of acronyms found in this manual.TABLE G-1 AcronymsAbbreviation Full nameASIC Applic

Page 231 - 13.3 Motherboard Unit Upgrade

G-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010DIMM Dual inline memory moduleDRAM Dynamic random access memoryEcache External

Page 232

Appendix G Abbreviations G-3PHP PCI hot plugPOST Power-on self-testPOR Power-on resetPSB Physical system boardPSU Power supply unitPROM Programmable r

Page 233

G-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

Page 234

Index-1IndexNumerics172-mm fan backplane, 10-13172-mm fan module, 10-160-mm fan backplane, 10-1060-mm fan module, 10-195364Head15.2 CD-RW/DVD-RW (DVDU

Page 235 - Backplane Unit Replacement

Chapter 2 Fault Isolation 2-72.2.2.1 Checking the Software ConfigurationThe following procedure for these checks can be made from the domain console:1

Page 236

Index-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010LLEDs, 2-11, 2-18Mmemory board, 11-1DIMMs, 11-7motherboard unit, 13-1DC-DC

Page 237

2-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.2.3 Downloading the Error Log InformationIf you want to download the error lo

Page 238

Chapter 2 Fault Isolation 2-9FIGURE 2-3 M4000 Server Operator PanellLocation Number Component1 POWER LED2 XSCF STANDBY LED3 CHECK LED4 Power switch5 M

Page 239

2-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 2-4 M5000 Server Operator PanelAdditional LEDs are located in various l

Page 240 - FIGURE 14-3)

Chapter 2 Fault Isolation 2-11The Operator panel LEDs operate as described in TABLE 2-3.TABLE 2-3 Operator Panel LEDs and SwitchesIcon Name Color Desc

Page 241

2-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010The state displayed by LED combination is described in TABLE 2-4.TABLE 2-4 Sta

Page 242 - 14.1.4 Securing the Server

Chapter 2 Fault Isolation 2-13The operator panel mode switch is used to set the operation mode. The operator panelpower switch is used to power on and

Page 243

2-14 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.4 Error ConditionsAlways access the following web site first to interpret fa

Page 244 - FIGURE 14-4)

Chapter 2 Fault Isolation 2-15 Diagnoses the problems. Initiates pro-active self-healing activities. For example, the fault manager candisable fault

Page 246 - 14.1.8 Securing the Server

2-16 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010TABLE 2-7 Predictive Self-Healing MessageOutput Displayed DescriptionNov 1 16:

Page 247

Chapter 2 Fault Isolation 2-172.4.2 Monitoring OutputTo understand error conditions, collect the monitoring output information. For thecollection of t

Page 248

2-18 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.5 LED FunctionsLED lights help the user find the component and provide infor

Page 249 - Operator Panel Replacement

Chapter 2 Fault Isolation 2-19TABLE 2-11 describes the components and their LEDs.TABLE 2-11 Component LED DescriptionsComponent LED Type LED Display M

Page 250 - 1 Operator panel

2-20 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010Power supply unit(PSU)READY On (green) Indicates that the power is turned on a

Page 251

Chapter 2 Fault Isolation 2-212.6 Using the Diagnostic CommandsAfter the message in TABLE 2-7 is displayed, you might desire more information aboutthe

Page 252

2-22 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.6.2 Using the fmdump CommandThe fmdump command can be used to display the co

Page 253 - FIGURE 15-3)

Chapter 2 Fault Isolation 2-232.6.2.2 fmdump -e CommandTo get information of the errors that caused this failure you can use the -e option, asshown in

Page 254 - Removing the Operator Panel

2-24 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010If fmadm faulty occurs, the FMA resource cache on the OS side can be clearedwi

Page 255 - 15.2.3 Securing the Server

Chapter 2 Fault Isolation 2-252.7 Traditional Oracle Solaris DiagnosticCommandsThese superuser commands can help you determine if you have issues in y

Page 256

vContentsPreface xvii1. Safety and Tools 1–11.1 Safety Precautions 1–11.2 System Precautions 1–21.2.1 Electrical Safety Precautions 1–21.2.2 Equipment

Page 257 - Components List

2-26 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.7.1 Using the iostat CommandThe iostat command iteratively reports terminal,

Page 258 - Number Component

Chapter 2 Fault Isolation 2-272.7.2 Using the prtdiag CommandThe prtdiag command displays configuration and diagnostic information. Thediagnostic info

Page 259

2-28 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010The following example shows output for the prtdiag command in verbose mode.# p

Page 260

Chapter 2 Fault Isolation 2-29The prtdiag -v output continued.IO Lane/FrqLSB Type LPID RvID,DvID,VnID BDF State Act, Max NameModel Logical Path

Page 261

2-30 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.7.3 Using the prtconf CommandSimilar to the show-devs command run at the ok

Page 262

Chapter 2 Fault Isolation 2-31The prtconf output continued.disk-label (driver not attached) terminal-emulator (driver not attached) obp-

Page 263 - B.1 Server Configuration

2-32 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.7.4 Using the netstat CommandThe netstat command displays the network status

Page 264 - System Features

Chapter 2 Fault Isolation 2-332.7.4.1 OptionsTABLE 2-15 describes options for the netstat command and how those options canhelp troubleshooting.The fo

Page 265 - System Features (Continued)

2-34 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.7.5 Using the ping CommandThe ping command sends ICMP ECHO_REQUEST packets t

Page 266

Chapter 2 Fault Isolation 2-352.7.6 Using the ps CommandThe ps command lists the status of processes. Using options and rearranging thecommand output

Page 267 - FRU List

vi SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.4 Error Conditions 2–142.4.1 Predictive Self-Healing Tools 2–142.4.2 Monitorin

Page 268 - FRU Components

2-36 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102.7.7 Using the prstat CommandThe prstat utility iteratively examines all acti

Page 269 - C.2 System Boards

Chapter 2 Fault Isolation 2-372.8 Other Issues2.8.1 Can’t Locate Boot DeviceWhen the PCI-X card slot 0 is faulty or it is not seated properly, the fir

Page 270 - C.2.2 CPU Module

2-38 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010

Page 271 - C.2.3 Memory Board

3-1CHAPTER3Periodic MaintenanceThis chapter describes the periodic maintenance required to keep the server runningregardless of whether a problem has

Page 272 - C.4 I/O Unit

3-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010 Replace the cleaning cassette when the tape inside of the cassette has comple

Page 273 - C.5 Power

4-1CHAPTER4FRU Replacement PreparationThis chapter describes how to prepare a field-replaceable unit (FRU) for safereplacement. The information is org

Page 274 - C.6 FAN Module

4-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010TABLE 4-1 lists the FRUs, location and access, and the replacement method.TABLE

Page 275 - 2 60-mm fans (1+ 1 redundant)

Chapter 4 FRU Replacement Preparation 4-3CPU module (CPUM_A) Top Cold replacementMemory board (MEMB) Top Cold replacementMotherboard (M4000) (MBU_A) R

Page 276 - C.8 Drives

4-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20104.2 Active ReplacementIn active replacement the Oracle Solaris OS must be confi

Page 277 - C.8.3 Tape Drive Unit (TAPEU)

Chapter 4 FRU Replacement Preparation 4-5Caution – If you use the PCI Hot Plug (PHP) function on the servers with OracleSolaris 10 9/10, or 142909-17

Page 278 - TABLE C-10)

Contents vii2.7.7.1 Options 2–362.8 Other Issues 2–372.8.1 Can’t Locate Boot Device 2–373. Periodic Maintenance 3–13.1 Tape Drive Unit 3–13.1.1 Cleani

Page 279 - APPENDIX

4-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20102. Type the cfgadm command to confirm the component is now connected.4.2.4 Veri

Page 280 - D.1 Serial Port

Chapter 4 FRU Replacement Preparation 4-74.3.1 Removing and Replacing a FRU1. From the XSCF Shell prompt, type the replacefru command.EXAMPLE 4-1 repl

Page 281 - D.3 USB Port

4-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010The replacefru command automatically tests the status of the component after th

Page 282

Chapter 4 FRU Replacement Preparation 4-94.3.2 Verifying Hardware Operation1. Type the showhardconf command to confirm the new component is installed.

Page 283 - UPS Controller

4-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010This sample shows the showhardconf output continued.Refer to the showhardconf

Page 284 - E.3 Signal Line Configuration

Chapter 4 FRU Replacement Preparation 4-112. Type the showhardconf -u command to display the number of FRUs in eachunit.Refer to the showhardconf -u m

Page 285 - E.4 Power Supply Conditions

4-12 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20104.4 Cold Replacement (Powering the ServerOff and On)In cold replacement all bu

Page 286 - E.5 UPS Cable

Chapter 4 FRU Replacement Preparation 4-13Caution – There is an electrical hazard if the power cords are not disconnected. Allpower cords must be disc

Page 287 - E.6 UPC Connector

4-14 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20104.4.3 Powering the Server Off Manually1. Notify users that the server is being

Page 288

Chapter 4 FRU Replacement Preparation 4-154.4.5 Verifying Hardware Operation1. From the ok prompt, press the Enter key, and press the “#.” (number sig

Page 289 - Air Filters

viii SPARC Enterprise M4000/M5000 Servers Service Manual • December 20105.2.1 Removing the Top Cover 5–55.2.2 Replacing the Top Cover 5–85.3 Fan Cover

Page 290 - Filter is installed

4-16 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010This sample shows the showhardconf output continued.Refer to the showhardconf

Page 291 - XSCF> showaltitude

Chapter 4 FRU Replacement Preparation 4-174. From the ok prompt, type the show-devs command to ensure all PCI cards aremounted:EXAMPLE 4-8 show-devsok

Page 292 - Hook and Loop Tape Locations

4-18 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20105. Type the probe-scsi-all command to confirm that the storage devices aremoun

Page 293 - Appendix F Air Filters F-5

5-1CHAPTER5Internal Components AccessThis chapter describes how to access the internal components. The information isorganized into the following topi

Page 294

5-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20105.1.1 Sliding the Server Out of the Equipment RackCaution – To prevent the equi

Page 295 - Appendix F Air Filters F-7

Chapter 5 Internal Components Access 5-3FIGURE 5-1 Loosening the Captive Screws on the Shipping Brackets

Page 296 - FIGURE F-6)

5-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20103. Loosen the four (4) captive screws at the front of the server (FIGURE 5-2).F

Page 297 - Appendix F Air Filters F-9

Chapter 5 Internal Components Access 5-55.2 Top Cover Remove and ReplaceYou must slide the server out of the equipment rack before removing the top co

Page 298

5-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106. Loosen the captive screw(s) on the center top of the server.The SPARC Enterp

Page 299 - Appendix F Air Filters F-11

Chapter 5 Internal Components Access 5-7FIGURE 5-4 Removing the M5000 Server Top Cover

Page 300

Contents ix6.2.7 Removing the CD-RW/DVD-RW Drive Backplane of the M4000Server 6–186.2.8 Installing the CD-RW/DVD-RW Drive Backplane of the M4000Server

Page 301 - FIGURE F-12)

5-8 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20105.2.2 Replacing the Top Cover1. Align the top cover and then slide it towards t

Page 302 - FIGURE F-10

Chapter 5 Internal Components Access 5-9Note – When drawing out the M400/M5000 Server to the front, release the cable tieholding the PCI cables on the

Page 303 - Appendix F Air Filters F-15

5-10 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010FIGURE 5-5 Removing the Fan Cover5.3.2 Replacing the Fan Cover1. Align the tab

Page 304

6-1CHAPTER6Storage Devices ReplacementThis chapter describes how to remove and install the main storage systems. Theinformation is organized into the

Page 305 - Abbreviations

6-2 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010 Section 6.1.10, “Removing the Hard Disk Drive Backplane of the M5000 Server”

Page 306 - Abbreviation Full name

Chapter 6 Storage Devices Replacement 6-3The following illustration shows the locations of the hard disk drives and the harddisk drive backplane on th

Page 307 - Appendix G Abbreviations G-3

6-4 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.1.1 Accessing the Hard Disk DriveNote – If the hard disk drive is the boot de

Page 308

Chapter 6 Storage Devices Replacement 6-56.1.3 Installing the Hard Disk DriveCaution – Do not force the hard disk drive into the slot. Doing so can ca

Page 309

6-6 SPARC Enterprise M4000/M5000 Servers Service Manual • December 20106.1.5 Accessing the Hard Disk Drive Backplane of theM4000 ServerCaution – There

Page 310

Chapter 6 Storage Devices Replacement 6-75. Remove all hard disk drives and place them on the ESD mat.See Section 6.1.2, “Removing the Hard Disk Drive