BX400 S1 Operating Manual 75
Installation and operation
Power Contains power management settings
Power settings (1) (Default values are highlighted):
Consumption mode (No Consumption Control / Enforced
Max. Limit / Low Noise Operation / Minimum Power Cons. /
Scheduled Cons. Mode)
PSU control enabled
PSU redundancy (No Redundancy / PSU Redundancy /
Phase Redundancy)
PSU Dynamic Mode enable (ON / OFF)
Power settings (2):
Maximum Power Limit (value of "Minimum Power Limit" as
printed in the same menu)
Power settings (3):
PSU/Phase Assignment (Unassigned)
Phase Limit (no value)
PIN Contains a four-digit PIN as password protection for the
ServerView Local Service Display for Blade
Default values:
PIN enabled (OFF)
PIN (0000)
Check Ekeying Check: This is a function which allows you to query the
compatibility of the modules before startup, and then activate,
partially activate or deactivate the module depending on the
result. For example, you would not activate modules whose
operating voltages or power consumption are not compatible with
the system.
This test begins automatically after switch-on or after a hardware
replacement. If errors are found, you can find out more about
them via the Details button. Replace the defective hardware
component and repeat the test.
Save Clicking the Save button saves and applies the settings in the
management blade.
With the Previous button you can go back and change
parameters. You save the changed configuration with the Save
button.