(2) LBA mode
Logical address assignment in the LBA mode starts from physical cylinder 0, physical head 0,
and physical sector 1. The logical address is advanced at the subsequent sector from the last
sector of the current track. The first physical sector of the subsequent physical track is the
consecutive logical sector from the last sector of the current physical track.
Figure 6.6 shows an example of (assuming there is no track skew).
LBA
2
LBA
1
SPSPLBA
240
241240
LBA
239
LBA
0
321
Physical sector
ex: Zone 0
Physical parameter
- Physical sector: 1 to 241 (For the rest, 2 spare sectors)
Physical cylinder 0
Physical head 0
......................
......................
SPSPLBA
481
LBA
480
321
Physical cylinder 0
Physical head 1
......................
......................
LBA
243
LBA
242
LBA
241
243242
241240 243242
Figure 6.6 Address translation (example in LBA mode)
6.3 Power Save
The host can change the power consumption state of the device by issuing a power command
to the device.
6.3.1 Power save mode
There are four types of power consumption state of the device including active mode where all
circuits are active.
In the power save mode, power supplying to the part of the circuit is turned off. There are
three types of power save modes:
Idle mode
Standby mode
Sleep mode