System configurator and order-information guide
A
PRIMERGY BX400 System Unit Status: 2013-03-28
Section
I
System Unit BX400 S1
S26361-K1335-V201
The System Unit BX400 S1 consists of:
* 6U chassis including
* Rack mounting kit suitable for
- PRIMERGY 19" PRIMECENTER Rack, FJ new rack and 3rd party racks (e.g. Rittal)
- 1 pair of carrier rails and 1 bracket for DC-Rack
* 1 Hot-plug PSU 1600W (230V) / 1100W (115V) with 2 fans at the rear side without power cable
* Drives / bays / slots
- 8 empty slots for 8 Server Blades at front side.
- 4 empty slots for Connection Blades at rear side
- 2 empty slots for additional hot-plug power supplies or fan modules at rear side
* 1 hot-plug Management Blades
* Front-Side-I/O-Module (FSIOM) provides 2x USB, 1x LAN, 1x serial port and 1 slot for front panel or LCD module
External Interfaces:
- 1x RS-232-C (serial, 9 pin) per Management Blade
- 2x Gb Ethernet per Management Blade
- 2x USB per Management Blade
- 1x VGA, 1x serial and 4x USB at front side of each Server Blade via special cable
- 2x USB at front side by FSIOM
- 1x Gb Ethernet (RJ45) at front side by FSIOM (redirected MMB LAN port)
- 1x RS-232-C (serial, 9 pin) at front side by FSIOM (redirected MMB serial port)
Cables (shipped with each System Unit):
- 1x special cable with 4x USB for external CD/FD, serial RS232 and 1x VGA for Server Blade front side connection.
Software:
- ServerView Suite Software package incl. ServerStart, ServerBooks, Management Software and Updates
Note: At least one Server Blade must be integrated in the System Unit ex works.
Server Blades can also be ordered for further extention later!
In total the number of configured PSU and Fan units must be three (3) !
- if no additional PSU is configured 3 Fan units must be configured
- if 1 additional PSU is configured 2 Fan units must be configured
- if 2 additional PSUs are configured 1 Fan unit must be configured
- if 3 additional PSUs are configured no Fan unit must be configured
Power and cooling considerations
Number
Number
Max. PSU PSU
of of Dual Server Redundancy
Redundancy
PSU FAN Blades 230V 115V
1 3 4 1+0 1+0
2 2 8 2+0 2+0
3 1 8 3+0 3+0
4 0 8 2+2 3+1
4 0 8 3+1 3+1
S26361-F3962-E500
Redundant BX900
1x Management Blade
max. 1x per system
S26361-F4474-E100 S26113-F607-E201
Rear Fan Unit Power Supply Unit (PSU)
(2 Fans per unit) 230V AC 1600W
115V AC 1100W
max. 3x per system without power cord
max. 3x per system
for BX400 within rack
please choose only 1 of this 2 cables
S26361-F3151-E301 S26361-F3151-E351 S26361-F3151-E200
Power Cord 16A Power Cord 10A Power Cord 16A
IEC 320 C19 -> C20
IEC 320 C19 -> C14
IEC 320 C19->
3x 16A CEE Blue
default within rack for 200V-240V only*) without rack only *) in System architect please
1x per PSU 1x per PSU 1x per PSU change the default 16A connection
to a 10A connection for all PSU
S26361-F3151-E100 S26361-F3151-E500 T26139-Y3850-E10
Power Cord 16 A
Power Cord No Power Cord
IEC320 C19->
IEC320 C19 ->
CEE7/7 Schuko US NEMA L6-20p
without rack only without rack only without rack only
1x per PSU
1x per PSU
1x per PSU
B
Fujitsu Technology Solutions x86 PRIMERGY Server 4 of 19