Installation GuideSPARC® Enterprise T5140 / T5240 Servers English
viii SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008
74 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 20082. Attach a mounting bracket to the right side of the server chassis.a.
Appendix C Installing the Servers With the Express Rail Rackmounting Kit 75FIGURE C-6 Express Rail Slide Rails Orientation for Installation
76 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 20085. Extend the slide rails (outer section) to fit the rack and attach th
Appendix C Installing the Servers With the Express Rail Rackmounting Kit 77Caution – The weight of the servers on extended slide rails can be enough t
78 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 20084. Slide the green release tab (FIGURE C-9).5. Push the server all the
Appendix C Installing the Servers With the Express Rail Rackmounting Kit 79Installing the Cable Management ArmThe rackmounting kit for each server com
80 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008
81IndexSymbols#. escape sequence for system console, 58Aaccessing ILOM command line, 45adapters for serial cables, 32address, IP, 4addresses, web, See
82 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008installation instructions, optional components,reference, 3installingmou
Index 83Ttermsleft and right sides, 15slide rail assembly, 10, 68TTYA serial port, 7Uuadmin command, 57unlocking mounting bracket, 71Wweb sitehttp://m
ixFiguresFIGURE 1-1 SPARC Enterprise T5140 Server 2FIGURE 1-2 SPARC Enterprise T5240 Server 2FIGURE 1-3 Rear Panel Cable Connectors and LEDs on the SP
84 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008
Herausgegeben von / Published byFujitsu Siemens Computers GmbH*U41767-J-Z816-1-76 *U41767-J-Z816-1-76 Bestell-Nr./ Order No.:U41767-J-Z816-1-76
x SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FIGURE 2-12 Unlocking the Slide Rail Assembly (Either Server) 29FIGURE 2-
xiTablesTABLE 1-1 Ethernet Connection Transfer Rates 7TABLE 3-1 Disk Slot Numbers, Logical Device Names, and Physical Device Names 55TABLE 3-2 Device
xii SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008
xiiiPrefaceThis manual provides instructions, background information, and reference materialto help you install SPARC®Enterprise T5140 and T5240 serve
xiv SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Structure and Contents of This ManualThis manual is organized as descri
Preface xvRelated DocumentationThe latest versions of all the SPARC Enterprise Series manuals are available at thefollowing Web sites:http://manuals.f
xvi SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Using UNIX CommandsThis document might not contain information about ba
Preface xviiPrompt NotationsThe following prompt notations are used in this manual.Conventions for Alert MessagesThis manual uses the following conven
xviii SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Caution – This indicates that hazardous voltages are present. To redu
Preface xixNotes on SafetyImportant Alert MessagesThis manual provides the following important alert signals:Caution – This indicates a hazardous situ
xx SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Caution – This indicates that hazardous voltages are present. To reduce
Preface xxiProduct HandlingMaintenanceWarning – Certain tasks in this manual should only be performed by a certifiedservice engineer. User must not pe
xxii SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Alert LabelThe following is a label attached to this product: Never p
Preface xxiii Reader's Comment Form
xxiv SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FOLD AND TAPEFOLD AND TAPEBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT
1CHAPTER1Preparing for InstallationThis chapter provides background information about the installation procedures forboth servers that are provided in
2 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FIGURE 1-1 SPARC Enterprise T5140 ServerFIGURE 1-2 SPARC Enterprise T5240
Chapter 1 Preparing for Installation 3Tools and Equipment NeededTo install the system, you must have the following tools: No. 2 Phillips screwdriver
SPARC®EnterpriseT5140 and T5240 ServersInstallation GuideOrder No. U41767-J-Z816-1-76Part No. 875-4310-10February 2008, Revision A
4 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Caution – To protect electronic components from electrostatic damage, whi
Chapter 1 Preparing for Installation 5Tip – The serial terminal or a terminal emulator should be connected before youconnect the power cables. As soon
6 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Refer to the SPARC Enterprise T5140 and T5240 Servers Product Notes for a
Chapter 1 Preparing for Installation 7 Ethernet ports are labeled NET0, NET1, NET2, and NET3. The Ethernet interfacesoperate at 10 Mbps, 100 Mbps, an
8 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FIGURE 1-3 Rear Panel Cable Connectors and LEDs on the SPARC Enterprise T
Chapter 1 Preparing for Installation 9See FIGURE 1-5 and FIGURE 1-6 for the locations of the ports on the SPARC EnterpriseT5240 server.FIGURE 1-5 Rear
10 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FIGURE 1-6 Front Panel USB Ports on the SPARC Enterprise T5240 ServerSli
Chapter 1 Preparing for Installation 11FIGURE 1-7 Sections of the Slide Rail Assembly on the SPARC Enterprise T5240 Server The front, middle, and rea
12 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FIGURE 1-8 Locating the Locks on the Slide Rail Assembly for the SPARC E
Chapter 1 Preparing for Installation 13Cable Management Notes for BothServersThe same cable management arm (CMA) is included with the rackmounting kit
Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.FUJITSU LIMITED provided technic
14 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Safety PrecautionsCaution – Deploy the antitilt bar on the equipment rac
15CHAPTER2Installing the SPARC EnterpriseT5140 and T5240 ServersThis chapter provides instructions for installing the servers into an equipment rack.N
16 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Note – The procedures in this chapter are the same for both the 1U and 2
Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 17c. Slide the mounting bracket release button in the direction shown inFIGURE 2-2,
18 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FIGURE 2-3 Unlocking the Slide Rail Middle Section (Either Server)2. Att
Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 19FIGURE 2-4 Attaching a Mounting Bracket to the Chassis (Either Server)b. Ensure th
20 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008 If your rack does not have threaded mounting holes, the mounting screw
Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 218. Use the slide rail spacing tool to adjust the distance between the slide rails.
22 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008▼ To Insert and Lock the Server in the Rack1. Deploy the antitilt bar, i
Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 233. Slide the chassis into the rack.Caution – Before continuing, verify that the se
Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, Etats-Unis. Tous droits réservés.Entrée et revue tecnical f
24 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FIGURE 2-8 Inserting the CMA Rail Extension Into the Rear of the Left Sl
Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 253. Insert the smaller extension into the clip located at the end of the mountingbr
26 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 20084. Insert the larger extension into the end of the right sliding rail (F
Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 275. Insert the hinged plastic connector at the left side of the CMA fully into theC
28 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008▼ To Verify the Operation of the Slide Rails andthe CMATip – Two people
Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 297. Pull both slide rail release buttons toward you simultaneously and slide theser
30 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Connecting the Server Cables for BothServersTo boot the server, you must
Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 31Use this port for server management. This port is needed to set up the serviceproc
32 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Note – The service processor network management port is configured by de
Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 33Powering on the system for the first time requires special preparation andprocedur
34 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Caution – Verify the operation of the slide rails and CMA, and cable ser
Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 35
36 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008
37CHAPTER3Powering On the SystemThis chapter includes instructions for booting the servers and for enabling theservice processor network management po
38 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Note – To see these status and error messages, connect a terminal or ter
Chapter 3 Powering On the System 39 No handshakeA null modem configuration is needed, meaning the transmit and receive signals arereversed (crossed o
40 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FIGURE 3-1 Server Connections4. (Optional) Connect an Ethernet cable bet
Chapter 3 Powering On the System 41Note – Only one power connection is required for operation. Use two powerconnections for redundancy.The service pro
42 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 20089. When prompted, follow the onscreen instructions for configuring the S
Chapter 3 Powering On the System 4310. Log in to the server and explore its capabilities.There are many commands you can use to verify the functionali
vContentsPreface xiii1. Preparing for Installation 1Tools and Equipment Needed 3Optional Component Installation 3ESD Precautions 3Installation Overvie
44 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Enabling the Service Processor NetworkManagement PortThe service process
Chapter 3 Powering On the System 452. Configure the service processor. See “To Configure the Service Processor NetworkManagement Port” on page 47.3. C
46 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 20081. If this is the first time the system has been powered on, use the pas
Chapter 3 Powering On the System 47▼ To Configure the Service Processor NetworkManagement PortNote – If your network allows the use of DHCP, this conf
48 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008a. If you choose to use a dynamically created IP address (use DHCP to re
Chapter 3 Powering On the System 49Note – After setting the configuration parameters, you must enter the set/SP/network commitpending=true command for
50 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008▼ To Log Into the Service Processor Using theNetwork Management PortNote
Chapter 3 Powering On the System 51▼ To Power On the System1. Perform the following steps to verify that there are no faults:a. Set the virtual keyswi
52 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008c. Switch to the system console to view POST output.Watch the POST outpu
Chapter 3 Powering On the System 534. Use the set /SYS keyswitch_state=normal command to return the virtualkeyswitch to Normal mode (default) so that
vi SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Connecting the Server Cables for Both Servers 31▼ To Connect the Service
54 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008The CPU and memory controllers initialize, and eventually OpenBoot initi
Chapter 3 Powering On the System 55Booting the Solaris Operating SystemThe Solaris OS is preinstalled on the servers on the disk in slot 0. The Solari
56 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008▼ To Boot the Solaris Operating System1. At the ok prompt, boot from the
Chapter 3 Powering On the System 57▼ To Reset the System● If it is necessary to reset the system, use the shutdown -g0 -i6 -ycommand.It is not necessa
58 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Note – To perform an immediate and ungraceful shutdown, use the stop -fo
Chapter 3 Powering On the System 59
60 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008
61APPENDIXAUpdating the FirmwareThis appendix provides instructions for updating SP firmware. “The flashupdate command” on page 61 “Updating the Fir
62 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008▼ To Update the Firmware1. Ensure that the ILOM service processor netwo
Appendix A Updating the Firmware 63 Full path name to the flash image that the IP address can accessThe command usage is as follows:load [-script] -s
Contents vii▼ To Power Cycle the System 57Verifying System Functionality 59A. Updating the Firmware 61The flashupdate command 61Updating the Firmware
64 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008... done.Mounting local filesystems...Cleaning /tmp /var/run /var/lock.
65APPENDIXBSelecting a Boot DeviceThis appendix provides instructions on selecting a boot device. “Selecting a Boot Device” on page 65Selecting a Boo
66 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008▼ To Select a Boot Device● At the ok prompt, type:where the device-spec
67APPENDIXCInstalling the Servers With theExpress Rail Rackmounting KitThis appendix provides instructions for installing the servers in an equipment
68 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008Slide Rail Assembly Notes for theExpress Rail Rackmounting KitThe expre
Appendix C Installing the Servers With the Express Rail Rackmounting Kit 69 The removable mounting bracket slides 14.5 in. (37 cm) out of the slide r
70 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FIGURE C-2 Locating the Locks on the Slide Rail Assembly for the SPARC
Appendix C Installing the Servers With the Express Rail Rackmounting Kit 71Installing the Servers in a Rack WithExpress RailsNote – Ensure that you ha
72 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008FIGURE C-3 Unlocking the Express Rail Slide Rail Assemblyb. Pull the mo
Appendix C Installing the Servers With the Express Rail Rackmounting Kit 73c. Slide the mounting bracket release button to the left (FIGURE C-4), then