Page 1 - GUI User Manual

AN706-00044-1v0-E 32-BIT MICROCONTROLLER MB9B100A/MB9B300A/MB9B400A/MB9B500A Series FM3 family inverter solution GUI User Manual ARM and Cort

Page 2 - AN706-00044-1v0-E

AN706-00044-1v0-E 5.3 GUI Startup Open the folder; double click the “ARMInverterPlatform.exe” to run the software, as Figure 5.2. Figure 5-2: GUI

Page 3 - Revision History

AN706-00044-1v0-E 5.4 GUI software windows’ name and function 5.4.1 Inverter Platform software introduce. - Name: Platform - Function: language se

Page 4 - Table of Contents

AN706-00044-1v0-E 5.4.2 Main window - Name : Main window - Function: connect control, start/stop control, function/parameter setting,

Page 5 - 1 Introduction

AN706-00044-1v0-E 6 Constant observation Observe system state, motor state, motor parameter, and so on.If the button is pushed, the constant windo

Page 6 - 2 System requirements

AN706-00044-1v0-E 5.4.3 Function/parameter settings window - Name : function/parameter settings window - Function: motor selection, m

Page 7 - 3 Install GUI

AN706-00044-1v0-E Table 5-2: setting window function Name of area Specification 1 Motor selection Select which motor need to set, compressor /

Page 8

AN706-00044-1v0-E - How to operation of “Function/parameter settings window” Open this window and you can see the default parameters values. If y

Page 9 - 5 How to use the GUI

AN706-00044-1v0-E If you want to save the setting value, after connecting to the board and setting some parameters, (1) Push “saveconfig” button un

Page 10 - Figure 5-2: GUI files

AN706-00044-1v0-E 5.4.4 Signal selection window - Name : select signal window - Function: signal page selection, signal selection, signal t

Page 11

AN706-00044-1v0-E Table 5-3: select signal function Name of area Specification 1 Signal page selection Select the signal page 2 Available

Page 12

AN706-00044-1v0-E All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJI

Page 13

AN706-00044-1v0-E 5.4.5 Graphic window - Name : wave observer window - Function: window name set, real-time drawing the wave, showing the sele

Page 14 - Figure 5-5: setting window

AN706-00044-1v0-E Table 5-4: wave observer function Name of area Description 1 Form name Custom the name of this wave window. 2 Show wave

Page 15

AN706-00044-1v0-E Reference line of Wave D Reference line of Wave C Reference line of Wave B Reference line of Wave A You can change the waveform c

Page 16

AN706-00044-1v0-E Also, you can adjust the waveform position each other. Select the waveform you want to adjust at the selectwave menu, and push the

Page 17

AN706-00044-1v0-E 5.4.6 Variable window - Name:variable observation window. - Function: show the signal value, select signal. 21 Fig

Page 18

AN706-00044-1v0-E 5.4.7 Constant window - Name : Constant observation window - Function: show the signal value; select signal. 21 Fi

Page 19

AN706-00044-1v0-E 5.5 Example of total operating Procedure This chapter introduces the operating method of GUI. 5.5.1 Hardware preparation Befo

Page 20

AN706-00044-1v0-E 1 Figure 5-10: operation: connect 26

Page 21

AN706-00044-1v0-E (2) Start running the motor Next, click Compressor Start-stop Control button in Main Window to start the motor (1 in the Figure 5

Page 22

AN706-00044-1v0-E (3) Set the motor function/parameter To set the function/parameter of motor, click Function/Parameter Setting button in Main Wind

Page 23

AN706-00044-1v0-E Revision History Rev Date Remark 1.0 Jul. 14, 2011 First Edition 2

Page 24

AN706-00044-1v0-E 132 4 Figure 5-13: operation: set compressor parameter 29

Page 25

AN706-00044-1v0-E (4) Show the wave To display the waveform, click Graphic button in Main Window (1 in Figure 5-14), and the Graphic Window in Figur

Page 26

AN706-00044-1v0-E 1 Figure 5-15: operation: open the select signal window Click Select Signal button (1 in Figure 5-15) to select the signal for wa

Page 27

AN706-00044-1v0-E 4 5 3 21 Figure 5-16: operation: select signal 32

Page 28

AN706-00044-1v0-E Figure 5-17: operation: draw the waveform 33

Page 29

AN706-00044-1v0-E 6 Appendix 6.1 Particular Install steps about the communication Driver 6.1.1 To install FTDI device in Windows XP - Copy and un

Page 30

AN706-00044-1v0-E Figure 6-2 - Select "Search for the best driver in these locations" and enter the file path in the combo-box ("¥CD

Page 31 - Figure 5-15 is displayed

AN706-00044-1v0-E Anyway" to continue with the installation. If Windows XP is configured to ignore file signature warnings, no message will a

Page 32

AN706-00044-1v0-E Figure 6-6 - If the device is based on the FT2232, the Found New Hardware Wizard will continue by installing the USB Serial Conv

Page 33

AN706-00044-1v0-E Figure 6-7 - Select "Install from a list or specific location (Advanced)" as shown in Figure 2.8 below and then click

Page 34

AN706-00044-1v0-E Table of Contents Revision History...

Page 35 - 6 Appendix

AN706-00044-1v0-E Figure 6-9 - If Windows XP is configured to warn when unsigned (non-WHQL certified) drivers are about to be installed, the mess

Page 36 - Figure 6-3

AN706-00044-1v0-E Figure 6-11 - Windows should then display a message indicating that the installation was successful (Figure 3-12). Click &quo

Page 37 - Figure 6-5

AN706-00044-1v0-E - Open the Device Manager (located in "Control Panel¥System" then select the "Hardware" tab and click "De

Page 38 - Figure 6-6

AN706-00044-1v0-E 6.1.2 FTDI Drivers Installation guide for Windows 7 - Connect the device to a spare USB port on your PC. - If there is an availa

Page 39 - Figure 6-8

AN706-00044-1v0-E Figure 6-16 - t the next screen select Device Manager: Figure 6-17 - In the Device Manager window there will be a device unde

Page 40 - Figure 6-10 warning

AN706-00044-1v0-E Figure 6-18 - Right click on the other device (TTL232R in this example) to bring up a menu as shown below. Figure 6-19 From t

Page 41 - Figure 6-12

AN706-00044-1v0-E Figure 6-20 45

Page 42 - Figure 6-14

AN706-00044-1v0-E - Select the second option to browse manually. Figure 6-21 - In the address box put the exact location where the drivers have

Page 43 - Figure 6-15

AN706-00044-1v0-E Figure 6-22 - When the installation has finished a completion screen is displayed. 47

Page 44 - Figure 6-17

AN706-00044-1v0-E Figure 6-23 - Press Close button to close this window and go back to the Device Manager Window. 48

Page 45 - Figure 6-19

AN706-00044-1v0-E 1 Introduction This user manual describes how to use FUJITSU’S FM3 Inverter Platform GUI. In Chapter 2, it explains system require

Page 46

AN706-00044-1v0-E Figure 6-24 The Device Manager will still show a device under Other Devices but in addition to this there is a new entry under Un

Page 47 - Figure 6-21

AN706-00044-1v0-E Figure 6-25 - From the displayed menu select “Update Driver Software…” This then displays the option for an automatic search or

Page 48 - Figure 6-22

AN706-00044-1v0-E Figure 6-26 - Select the second option to browse manually. Figure 6-27 51

Page 49 - Figure 6-23

AN706-00044-1v0-E In the address box put the exact location where the drivers have been saved to. This may be on a CD or in a folder on the PC. It is

Page 50 - Figure 6-24

AN706-00044-1v0-E - When the installation is finished a completion screen is displayed. Figure 6-29 - Note this screen also displays the COM port

Page 51 - Figure 6-25

AN706-00044-1v0-E Figure 6-30 This time the Device Manager does not have a TTL232R entry under Other Devices but does show entries under Universal

Page 52 - Figure 6-27

AN706-00044-1v0-E 556.2 Motor parameter item Table 6-1: motor parameter Motor parameter name Unit Init Value compressor model - DA89 pole pa

Page 53 - Figure 6-28

AN706-00044-1v0-E 2 System requirements The GUI software supported environment on PC 2.1 Supported Operating Systems: Windows Server 2003, Windows

Page 54 - Figure 6-29

AN706-00044-1v0-E 3 Install GUI Install the GUI software in your PC This FUJITSU’S FM3 Inverter Platform GUI is given by compressed file, please c

Page 55 - Figure 6-30

AN706-00044-1v0-E 4 Simply install steps about the communication Driver A simply install steps for the FTDI. 4.1 To install FTDI driver in Windows

Page 56

AN706-00044-1v0-E 5 How to use the GUI Introduce the GUI software 5.1 Overview This GUI use to cooperate with the FUJITSU’S FM3 inverter platform