Fujitsu MPB3052AT User Manual Page 95

  • Download
  • Add to my manuals
  • Print
  • Page
    / 180
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 94
C141-E045-02EN5 - 30
Table 5.4 Information to be read by IDENTIFY DEVICE command (1 of 3)
Word Value Description
0 X‘0C5A’ General Configuration *1
1 X‘1176’
X‘1A30’
X‘22EC’
X‘2A62’
X‘3462’
Number of cylinders MPB3021AT: X‘1176’
MPB3032AT: X‘1A30’
MPB3043AT: X‘22EC’
MPB3052AT: X‘2A62’
MPB3064AT: X‘3462’
2 X‘0000’ Reserved
3 X‘000F’ Number of Heads
4 X‘0000’ Retired
5 X‘0000’ Retired
6 X‘003F’ Number of sectors per track
7-9 X‘000000000000’ Retired
10-19 Serial number (ASCII code) *2
20-21 X‘00000000’ Retired
22 X‘0004’ Number of ECC bytes transferred at READ LONG or WRITE LONG command
23-26 Firmware revision (ASCII code) *3
27-46 Model number (ASCII code) *4
47 X‘8010’ Maximum number of sectors per interrupt on READ/WRITE MULTIPLE command
48 X‘0000’ Reserved
49 X‘0B00’ Capabilities *5
50 X‘0000’ Reserved
51 X‘0200’ PIO data transfer mode *6
52 X‘0000’ Retired
53 X‘0003’ or
X‘0007’
Enable/disable setting of words 54-58, 64-70 and 88 *7
54 (Variable) umber of current Cylinders
55 (Variable) Number of current Head
56 (Variable) Number of current sectors per track
57-58 (Variable) Total number of current sectors
59 *8 Transfer sector count currently set by READ/WRITE MULTIPLE command
60-61 X‘00407496’
X‘0060AB30’
X‘0080E92C’
X‘009C73C2’
X‘00C15DC2’
Total number of user addressable sectors (LBA mode only) MPB3021AT: X‘00407496’
MPB3032AT: X‘0060AB30’
MPB3043AT: X‘0080E92C’
MPB3052AT: X‘009C73C2’
MPB3064AT: X‘00C15DC2’
62 X‘0000’ Retired
63 X‘xx07’ Multiword DMA transfer mode *9
64 X‘0003’ Advance PIO transfer mode support status *10
65 X‘0078’ Minimum multiword DMA transfer cycle time per word : 120 [ns]
66 X‘0078’ Manufacturer's recommended DMA transfer cycle time : 120 [ns]
67 X‘00F0’ Minimum PIO transfer cycle time without flow control : 240 [ns]
68 X‘0078’ Minimum PIO transfer cycle time with IORDY flow control : 120 [ns]
69-79 X‘00’ Reserved
80 X‘000E’ Major version number *11
81 X‘0000’ Minor version number (not reported)
82 X‘0009’ Support of command sets *12
83 X‘4000’ Support of command sets (fixed)
84-87 X‘00’ Reserved
88 X‘xx07’ Ultra DMA modes *13
Page view 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 179 180

Comments to this Manuals