Installation & Maintenance Manual TeamPoS 3000 XL and XL 2
Preface TeamPoS 3000 XL and XL2 xiii Issue 3 D90000145 10.1.6 SATA Port 2 Setup – XL2 10.1.7 SATA Port 3 Setup – XL Motherboard ...
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-54 3. Thread the cables through the stand beginning with the larger cables first.
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-55 6. Place the first LCD face down on a clean dry surface. Remove the back cover
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-56 9. Place the second LCD face down on a clean dry surface. Remove the back cove
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-57 5.14.4 DVI15 LCD The DV15 LCD comes in two configurations, touch and non touch.
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-58 Touch Configuration with A-B USB and Power Brick Unscrew these f
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-59 DV15 ready for VESA mounting
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-60 Connecting/ Forming the Cables (1) Open the Back Cover - Press the side wall of
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-61 Configuring the screen by OSD (On Screen Display) Menu (1) Buttons on the Fron
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-62 function doesn’t does not work properly, because it uses the signal at the edges
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-63 (3) OSD Menu Structure - The following table shows the menu structure of the OSD
TeamPoS 3000 XL and XL2 Overview D900000145 Issue 3 1-1 Chapter 1. Overview This manual is provided to illustrate how to install and maintain t
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-64 5.15. Installing the MSR or Keypad/MSR The following instructions show the Key
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-65 4. With the Keypad/MSR facing down, remove the back cover by pushing in on the
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-66 6. Insert connector cable into the connector in the Keypad/MSR. The cable only
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-67 5.16. Installing the VF60 in Stacked Stand Parts required for assembly of the V
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-68 4. Remove the cosmetic back panel of the VF60 display. 5. Connect the white
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-69 7. Fit the hooks of the tileter mechanism into the openings in the back of the d
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-70 9. Adjust the pole to the desired height and tighten locking collar in a clockw
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-71 12. Fit the collar into place. 13. Install on TeamPoS 3000 controller (See sec
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-72 5.17. Stacking the LCD Monitor The LCD stacked monitor stand has notches in th
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-73 2. Slide display into place by setting it so that the front edge of the LCD stan
TeamPoS 3000 XL and XL2 Overview D900000145 Issue 3 1-2 1.1. TeamPoS 3000 Control Unit Flow Diagram (XL Motherboard only)
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-74 4. Put cosmetic face plate over the opening in the stand . 5. When removing
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-75 5.18. Installing the Central Filler and Keyboard 5.18.1 Installing the Keyboar
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-76 2. Place the 133UQ or 133AU keyboard on the ledge for the keyboard, 3. Ru
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-77 5.18.2 Installing the Central Filler The Central Filler is used to occupy the f
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-78 5.19. Installing the Printer I/O Board (DT50 Series only). The DT 50 Series pr
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-79 4. Insert the I/O board (it only fits one way) and attach with screws.
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-80 5.20. Stacking the Printers Both the DT50 Series and the CT-10 printers stack o
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-81 2. Place the printer approximately ½” in front of the keyboard lip with the left
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-82 5.20.2. Stacking the CT10 Printer 1. Install Central Filler (S
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-83 4. Slide Front Filler from back to front until it catches the bracket. If the fr
TeamPoS 3000 XL and XL2 Overview D900000145 Issue 3 1-3 1.2. TeamPoS 3000 XL2 Control Unit Flow Diagram (XL2 Motherboard only) USB (STD)opera
TeamPoS 3000 XL and XL2 General Operations D900000145 Issue 3 6-1 Chapter 6 - General Operations 6.1 System Operations This section contain
TeamPoS 3000 XL and XL2 General Operations D900000145 Issue 3 6-2 5. If the keyboard or LCD has the MSR option installed, pass a magnetic str
TeamPoS 3000 XL and XL2 General Operations D900000145 Issue 3 6-3 6.1.3 Powering ON 1. Make sure all peripherals are securely connected to t
TeamPoS 3000 XL and XL2 General Operations D900000145 Issue 3 6-4 6.1.4 Powering OFF 1. Lift the plastic switch cover. 2. Press the ON/OF
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-1 Chapter 7 - Maintenance Caution: Confirm that the external power source is 100-2
TeamPoS 3000 XL and XL2 Maintenance 7-2 Issue 3 D900000145 7.1.1.1 Powering On 1. Make sure all peripherals are securely connected to the con
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-3 7.1.1.2 Powering OFF 1. Lift the plastic switch cover. 2. Press the ON/OFF switch
TeamPoS 3000 XL and XL2 Maintenance 7-4 Issue 3 D900000145 7.2 Replacing the Motherboard Caution: Be sure to observe all ESD precautions an
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-5 5. Remove hard disk from unit by pressing down on the metal latch (CH1 or CH2) bel
TeamPoS 3000 XL and XL2 Maintenance 7-6 Issue 3 D900000145 7. Pull the entire assembly out of the controller. Unscrew motherboard from chassi
TeamPoS 3000 XL and XL2 Overview D900000145 Issue 3 1-4 1.3. Front Panel LED's and Switches The following graphic and table show the Te
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-7 11. Push in slowly until motherboard assembly engages the lever. 12. Use the lev
TeamPoS 3000 XL and XL2 Maintenance 7-8 Issue 3 D900000145 7.2.1 XL Motherboard Layout J4 DDR DIMM Memory B DDR DIMM Memor
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-9 7.2.2 XL Motherboard Settings Switch and jumper settings on the TP3000 XL mother
TeamPoS 3000 XL and XL2 Maintenance 7-10 Issue 3 D900000145 7.2.3 Picture of XL Motherboard CLR_CMOS 1 - 2 CMOS Clear 2 - 3 No
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-11 7.2.4 XL2 Motherboard Layout J1-A J1-B J1-C SATA (for kiosk mode) To OP Pan
TeamPoS 3000 XL and XL2 Maintenance 7-12 Issue 3 D900000145 7.2.5 XL2 Motherboard Settings Switch and jumper settings on the TP3000 XL2Settin
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-13 7.2.6 Photo of XL2 Motherboard SW1 CMOS J13 LVDS JP1 J10 +5v STBY LED CPU
TeamPoS 3000 XL and XL2 Maintenance 7-14 Issue 3 D900000145 7.3 Replacing the CPU and Heat Sink Caution: Be sure to observe all ESD precauti
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-15 6. Open the CPU lock by turning ¼ turn counterclockwise. Lock and Unlocked i
TeamPoS 3000 XL and XL2 Maintenance 7-16 Issue 3 D900000145 7.4 Replacing the Hard Disk Drives Caution: Be sure to observe all ESD precauti
TeamPoS 3000 XL and XL2 Overview D900000145 Issue 3 1-5 1.3.1. TeamPoS 3000 Front Panel Switch and LCD Matrix Symbols Name Switch/LED Mountin
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-17 5. Press firmly to make the connection. 6. Reinstall the front panel (See Sect
TeamPoS 3000 XL and XL2 Maintenance 7-18 Issue 3 D900000145 5. Remove memory by pressing down on the white locking levers at the side of each
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-19 7.5.2 Adding or Replacing XL2 Motherboard Memory Caution: Be sure to observe a
TeamPoS 3000 XL and XL2 Maintenance 7-20 Issue 3 D900000145 5. Remove old memory by pulling outward on the small metal latches at the side of
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-21 8. If two memory sticks are being replaced, insert the 2nd stick in the top slot
TeamPoS 3000 XL and XL2 Maintenance 7-22 Issue 3 D900000145 12. If this is an upgrade, install the upgrade label that comes with the upgrade ki
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-23 6. Remove the metal mount with the old CD/DVD drive attached by unscrewing the 2
TeamPoS 3000 XL and XL2 Maintenance 7-24 Issue 3 D900000145 8. The power cable and ribbon cable come attached to the back of the CD/DVD drive.
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-25 12. Reinstall the back panel (See Section 5.1.2). 13. If this is an upgrade, in
TeamPoS 3000 XL and XL2 Maintenance 7-26 Issue 3 D900000145 5. Disconnect the white power cable for the battery and remove the old battery.
TeamPoS 3000 XL and XL2 Overview D900000145 Issue 3 1-6 1.4. Intelligent PIN's (Product Identification Numbers) TeamPoS 3000 Controller
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-27 7. Attach the protective front cover with retained screws. 8. Reinstall the fr
TeamPoS 3000 XL and XL2 Maintenance 7-28 Issue 3 D900000145 6. Slide the locking bar to the left and lift it out. The entire backplane assemb
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-29 7.9 Replacing I/O boards Caution: Be sure to observe all ESD precautions and p
TeamPoS 3000 XL and XL2 Maintenance 7-30 Issue 3 D900000145 I/O boards are connected to the backplane assembly. Refer to the instructions whic
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-31 Caution: Ports designated as Port C on the backplane (24V PUSB) and Port 3 on th
TeamPoS 3000 XL and XL2 Maintenance 7-32 Issue 3 D900000145 7. Remove 2 mounting screws holding the upper filler plate. Retain screws and reta
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-33 10. Replace the locking bracket with the plug. 11. Reinstall the back plane as
TeamPoS 3000 XL and XL2 Maintenance 7-34 Issue 3 D900000145 7.9.2.1 USB Board Jumper Settings JP3, 4 & 5 Power Source 1-2 +5V 2-3 +5VSB
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-35 7.9.3 Combo Board Combo cards provide support for both USB and legacy devices.
TeamPoS 3000 XL and XL2 Maintenance 7-36 Issue 3 D900000145 This second diagram shows a Backplane Assembly with the Combo Board and a blanking p
TeamPoS 3000 XL and XL2 Overview D900000145 Issue 3 1-7 This Page Intentionally Left Blank
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-37 7.9.3.1 Combo Board Installation 1. Remove the rear panel (See Section 5.1.2).
TeamPoS 3000 XL and XL2 Maintenance 7-38 Issue 3 D900000145 8. Flip the Combo board and attach it to the top opening of the chassis by sliding
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-39 7.9.3.2 Combo Board Diagram The following illustration shows the TeamPoS 3000 XL
TeamPoS 3000 XL and XL2 Maintenance 7-40 Issue 3 D900000145 7.9.3.3 Combo Board Jumper Settings The jumper block with 7 connectors (PRT1-7) an
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-41 7.9.3.4 Combo Board (picture) Combo Board
TeamPoS 3000 XL and XL2 Maintenance 7-42 Issue 3 D900000145 7.9.3.5 Combo Board COM 4 Port Connector Signals Connector type: Male DB9, (RS-23
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-43 7.9.3.6 Printer (PTR) Connector signals Connector type: Female D15 Pin # Signal
TeamPoS 3000 XL and XL2 Maintenance 7-44 Issue 3 D900000145 7.9.4 Combo Board with COM Board (XL Motherboard only) 1. Remove the rear panel
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-45 8. Invert Combo board (ports face away from the backplane). Connect the three po
TeamPoS 3000 XL and XL2 Maintenance 7-46 Issue 3 D900000145 11. Attach the COM board to the bottom opening in the backplane assembly by sliding
TeamPoS 3000 XL and XL2 Environmental Specifications D900000145 Issue 3 2-1 Chapter 2 Environmental Specifications The figure below shows a t
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-47 12. Flip combo board and attach the combo board to the top opening of the chassis
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-48 13. Reattach the retainer clip and the black pin. 14. Insert the backplane asse
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-49 7.9.4.1 COM Board Connectors (XL Motherboard only) COM Card XL Motherboard Onl
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-50 7.9.4.2 COM Board Jumpers PW2 COM6 PW1 COM5 1-2 RI 1-2 RI 3-4 +5VSB 3-4 +
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-51 7.10 Replacing PCI Add-In Card(s) Caution: Be sure to observe all ESD precauti
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-52 7. Insert the new PCI card into the slot and seat firmly. 8. Secure PCI card
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-53 7.11 Replacing the Power Supply 1. Remove the back panel (See Section 5.1.2). 2
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-54 8. Remove the three connectors for the power supply. 9. Install the new p
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-55 7.12 Replacing the Power Supply Fan 1. Remove the back panel (See Section 5.1.2
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-56 9. Install the new power supply fan by first connecting the cable and then mounting
TeamPoS 3000 XL and XL2 Environmental Specifications D900000145 Issue 3 2-2 2.1 Environmental Specifications for both XL and XL 2 Specification
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-57 7.13 Replacing the Backplane Caution: Be sure to observe all ESD precautions a
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-58 7. Slide the locking bar to the left and lift it out. The entire backplane and pow
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-59 11. Remove the 8 hex standoffs of the COM ports. (Retain standoffs.) 12. R
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-60 13. Insert new backplane PCB into the chassis fitting the com ports into the opening
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-61 7.13.1 Backplane Jumpers & Connectors PCI slot for add in cards JP1 – Power
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-62 7.13.2 TeamPoS 3000 Pin Assignments - Backplane Cash Drawer COM1 & 2 USB +24V
TeamPoS 3000 XL and XL2 Maintenance D900000145 Issue 3 7-63 This Page Intentionally Left Blank
TeamPos 3000 XL and XL2 Troubleshooting D900000145 Issue 3 8-1 Chapter 8 - Troubleshooting 8.1 Power cannot be turned on or the unit powers
TeamPos 3000 XL and XL2 Troubleshooting D900000145 Issue 3 8-2 8.2 System will not boot up (The system fails to start up even though the pow
TeamPos 3000 XL and XL2 Troubleshooting D900000145 Issue 3 8-3 8.3 Display/LCD shows correctly during Power On Self Test (POST), but fails w
TeamPoS 3000® Installation and Maintenance Manual
TeamPoS 3000 XL and XL2 Environmental Specifications D900000145 Issue 3 2-3 Environmental Specifications (cont.) Specifications Unit LCD disp
TeamPos 3000 XL and XL2 Troubleshooting D900000145 Issue 3 8-4 8.4 Display/LCD is blank at all times No Check item Judgment Action 1 Is the
TeamPos 3000 XL and XL2 Troubleshooting D900000145 Issue 3 8-5 8.5 Printing errors No Check items Judgment Action 1 Is receipt paper set cor
TeamPos 3000 XL and XL2 Troubleshooting D900000145 Issue 3 8-6 8.6 Impossible to input data from keyboard and/or abnormal input No Check it
TeamPos 3000 XL and XL2 Troubleshooting D900000145 Issue 3 8-7 8.7 Keyboard MSR reading error No Check item Judgment Action 1 Is the keyboa
TeamPos 3000 XL and XL2 Troubleshooting D900000145 Issue 3 8-8 8.8 Cash Drawer Operation errors No Check item Judgment Action 1 Is the cash
TeamPos 3000 XL and XL2 Troubleshooting D900000145 Issue 3 8-9 8.10 Deletion of Date, time and disk setup data when turning off power No Ch
TeamPos 3000 XL and XL2 Troubleshooting D900000145 Issue 3 8-10 8.12 Operation errors of other peripheral devices No Check item Judgment Ac
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-1 Chapter 9. BIOS Setup Procedures – Aurora Motherboard If a motherboard is
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-2 9.1.2 Main Menu – Motherboard Note: An arrow [] indicates additional sc
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-3 9.1.3 Standard CMOS Setup - Motherboard Factory Default Settings Phoen
TeamPoS 3000 XL and XL2 Environmental Specifications D900000145 Issue 3 2-4 This page intentionally left blank.
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-4 9.1.4 BIOS Features Setup - Motherboard Factory Default Settings Phoen
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-5 9.1.5 CPU Feature Setup - Motherboard Factory Default Settings Phoeni
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-6 9.1.6 Hard Disk Boot Priority - Motherboard Factory Default Settings P
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-7 9.1.7 Advance Chipset Features Setup- Motherboard Factory Default Setting
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-8 9.1.8 Integrated Peripherals Setup - Motherboard Factory Default Settings
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-9 9.1.9 USB Configuration Setup - Motherboard Factory Default Settings P
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-10 9.1.11 Onboard Device Setup - Motherboard Factory Default Settings Pho
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-11 9.1.12 SuperIO Device Setup - Motherboard Factory Default Settings Pho
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-12 9.1.13 Power Management Setup - Motherboard Factory Default Settings P
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-13 9.1.14 PnP/PCI Configurations Setup - Motherboard Factory Default Setting
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-1 Chapter 3 - DIMENSIONS This section shows the dimensions of the TeamPoS 3000 XL an
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-14 9.1.16 Hardware Monitoring Setup - Motherboard Factory Default Settings
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-15 9.1.17 Event Log Setup - Motherboard Factory Default Settings Phoenix
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-16 9.1.19 System Information - Motherboard Factory Default Settings Phoen
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-17 9.1.20 Set Supervisor/User Passwords - Motherboard Factory Default Settin
TeamPos 3000 XL and XL2 BIOS XL Motherboard D900000145 Issue 3 9-18 This page intentionally left blank.
TeamPoS 3000 XL and XL 2 BIOS XL2 Motherboard D900000145 Issue 3 10-1 Chapter 10. BIOS Setup Procedures – XL2 If a motherboard is replaced
TeamPoS 3000 XL and XL2 BIOS XL2 Motherboard D900000145 Issue 3 10-2 10.1.2. Main Menu – XL2 Motherboard Note: An arrow [] indicates addit
TeamPoS 3000 XL and XL 2 BIOS XL2 Motherboard D900000145 Issue 3 10-3 10.1.3. IDE Primary/Master Setup – XL2 Factory Default Settings Moth
TeamPoS 3000 XL and XL2 BIOS XL2 Motherboard D900000145 Issue 3 10-4 10.1.4. IDE Primary/Master Setup – XL2Factory Default Settings Motherb
TeamPoS 3000 XL and XL 2 BIOS XL2 Motherboard D900000145 Issue 3 10-5 10.1.5. SATA Port 1 Setup – XL2Factory Default Settings Motherboard
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-2 3.1.1 Model D22 & D25 LCD in Dual Stacked Configuration Note: Dimensions sh
TeamPoS 3000 XL and XL2 BIOS XL2 Motherboard D900000145 Issue 3 10-6 10.1.6. SATA Port 2 Setup – XL2Factory Default Settings Motherboard Pho
TeamPoS 3000 XL and XL 2 BIOS XL2 Motherboard D900000145 Issue 3 10-7 10.1.7. SATA Port 3 Setup – XL2Factory Default Settings Motherboard
TeamPoS 3000 XL and XL2 BIOS XL2 Motherboard D900000145 Issue 3 10-8 10.1.8. Advanced Main Menu – XL2Factory Default Settings Motherboard P
TeamPoS 3000 XL and XL 2 BIOS XL2 Motherboard D900000145 Issue 3 10-9 10.1.9. CPU Feature Setup – XL2Factory Default Settings Motherboard
TeamPoS 3000 XL and XL2 BIOS XL2 Motherboard D900000145 Issue 3 10-10 10.1.11. ICH8MDO Feature Setup – XL2Factory Default Settings Motherbo
TeamPoS 3000 XL and XL 2 BIOS XL2 Motherboard D900000145 Issue 3 10-11 10.1.12. USB Feature Setup – XL2Factory Default Settings Motherboar
TeamPoS 3000 XL and XL2 BIOS XL2 Motherboard D900000145 Issue 3 10-12 10.1.13. ICH SATA PATA Control Sub-Menu Setup – XL2Factory Default Sett
TeamPoS 3000 XL and XL 2 BIOS XL2 Motherboard D900000145 Issue 3 10-13 10.1.14. Super IO Feature Setup – XL2All options are shown here, howe
TeamPoS 3000 XL and XL2 BIOS XL2 Motherboard D900000145 Issue 3 10-14 10.1.15. Hardware Monitor Feature Setup – XL2All options are shown her
TeamPoS 3000 XL and XL 2 BIOS XL2 Motherboard D900000145 Issue 3 10-15 10.1.16. Other Feature Setup – XL2 All options are shown here, howev
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-3 Dimensions shown above indicate the smallest space requirement to accommodate the pr
TeamPoS 3000 XL and XL2 BIOS XL2 Motherboard D900000145 Issue 3 10-16 10.1.17. Security Setup – XL2Factory Default Settings Motherboard Pho
TeamPoS 3000 XL and XL 2 BIOS XL2 Motherboard D900000145 Issue 3 10-17 10.1.19. Power Setup – XL2Factory Default Settings Motherboard Phoe
TeamPoS 3000 XL and XL2 BIOS XL2 Motherboard D900000145 Issue 3 10-18 10.1.20. Boot Setup – XL2 All options are shown here, however on the BI
TeamPoS 3000 XL and XL 2 BIOS XL2 Motherboard D900000145 Issue 3 10-19 10.1.21. Exit Menu – XL2Factory Default Settings Motherboard Phoeni
TeamPoS 3000 XL and XL2 Spare Parts D900000145 Issue 3 11-1 Chapter 11 SPARE AND UPGRADE PARTS LIST Parts labeled “Reference only” are not or
Spare Parts TeamPoS 3000 XL and XL2 D900000145 Issue 3 11-2 DESCRIPTION FTXS # COMMENT CPU, Intel, Celeron M, 1.5 GHz 11000234 HeatSi
TeamPoS 3000 XL and XL2 Spare Parts D900000145 Issue 3 11-3 DESCRIPTION FTXS # COMMENT CD Drive Options OPN TP3K CD-ROMWHT 11000031 OPN TP
Spare Parts TeamPoS 3000 XL and XL2 D900000145 Issue 3 11-4 DESCRIPTION FTXS # COMMENT D22/D25 Stand, Stacked, BLK 11000353 LCD Mount
TeamPoS 3000 XL and XL2 Spare Parts D900000145 Issue 3 11-5 DESCRIPTION FTXS # COMMENT Mount for Display Pole, WHT 11000314 Plastic Ca
Spare Parts TeamPoS 3000 XL and XL2 D900000145 Issue 3 11-6 DESCRIPTION FTXS # COMMENT Front of Printer Spacer Bracket 11000380 Print
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-4 3.3 Keyboards 3.3.1 Model 133 UQ Keyboard Dimensions (PIN #s 90000829 white, 900
TeamPoS 3000 XL and XL2 Spare Parts D900000145 Issue 3 11-7 DESCRIPTION FTXS # COMMENT Blank Tiles, Gray, Qty=100, Fill unused positions 900007
Spare Parts TeamPoS 3000 XL and XL2 D900000145 Issue 3 11-8 DESCRIPTION FTXS # COMMENT CBL D22 D25 USB A-A/0.65M/BLK 11000120 LCD to external
TeamPoS 3000 XL and XL2 Spare Parts D900000145 Issue 3 11-9 DESCRIPTION FTXS # COMMENT CBL VF60 Pwrd USB/0.85M/BLK 11002794 CBL VF60 Pwrd USB/
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-5 3.3.3 Model 92U Keyboard Dimension (PIN # 90000630) 3.4 Cash Drawers 3.4.1 Mod
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-6 Standard Cash Drawer in Open Position 122 4 ¾” incl. 3/4” for feet
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-7 3.4.2 Model TP5C Cash Drawer - Compact (11000147 white w/o lock, 11000149 white w/
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-8 3.5 Displays 3.5.1 Model D22 LCD and Model D25 LCD Displays Two LCD’s are offered
TeamPoS 3000 XL and XL2 Preface D90000145 Issue 3 vi Fujitsu Transaction Solutions Inc. endeavors to ensure that the information in t
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-9 (11000742-1000744 white, 11000745-11000746 black) Model D25 LCD
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-10 3.5.3 Model D22 & D25 LCD’s on Stacked Stand. (PIN #’s 11000064-white 11000
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-11 3.5.5 Model D22 & D25 LCD on Single Stacked Stand w/MSR & VF60 Display (
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-12 3.5.6 Model D22 & D25 LCD on Dual Stacked Stand (PIN #’s 11000481-white, 11000
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-13 3.5.7 Model D25 & D25 on Dual Stacked Stand (PIN #’s 11000742-744 white,
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-14 3.5.9 Model D22 & D25 LCD on Dispersed Stands (PIN #’s 11000074 white, 1100007
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-15 3.5.11 VF60 Customer Display (dispersed) (VF60 PIN #’s 11000076-white, 11000077-bl
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-16 3.6 Printers Two printers are available for the TeamPoS 3000 XL and XL2: the DT50
TeamPoS 3000 XL and XL2 Dimensions D900000145 Issue 3 3-17 This page intentionally left blank.
TeamPoS 3000 XL and XL2 Site Preparation D900000145 Issue 3 4-1 Chapter 4 SITE PREPARATION This chapter defines the following pre-installatio
Preface TeamPoS 3000 XL and XL2 vii Issue 3 D90000145 Regulatory Information EMC Radio Frequency Interference Requirements – U.S.A. This equip
TeamPoS 3000 XL and XL2 Site Preparation D900000145 Issue 3 4-2 4.2 Reporting Shipment Damage If any damage is detected, it is both the recip
TeamPoS 3000 XL and XL2 Site Preparation D900000145 Issue 3 4-3 4.5 Preparing for Installation: Before installing equipment, perform the fol
TeamPoS 3000 XL and XL2 Site Preparation D900000145 Issue 3 4-4 4.7 General Requirements 1. The safety standards for Information Technology
TeamPoS 3000 XL and XL2 Site Preparation D900000145 Issue 3 4-5 system. The terminals must not be directly connected to a power system with im
TeamPoS 3000 XL and XL2 Site Preparation D900000145 Issue 3 4-6 4.8 Installation with Other Equipment In most cases, dedicated AC mains circu
TeamPoS 3000 XL and XL2 Site Preparation D900000145 Issue 3 4-7 4.9 Mains Power Cables The mains power cables for the TeamPoS 3000XL and XL2 t
TeamPoS 3000 XL and XL2 Site Preparation D900000145 Issue 3 4-8 Back View of control unit Bottom of the TeamPoS Contro
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-1 CHAPTER 5 INSTALLATION Caution: Confirm that the external power source is 100-2
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-2 2. Loosen thumbscrew. 3. The metal locking tab (behind the thumbscrew) will li
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-3 5. To reinstall, insert the tabs of the front panel into notches in the chassis.
TeamPoS 3000 XL and XL2 Preface D90000145 Issue 3 viii Recycling WARNING: The LCD’s used with this product may contain a backlight that contai
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-4 3. To reinstall the rear panel, insert the metal tabs into the sides of the chass
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-5 5. Pull white release lever below the motherboard assembly out and to the left.
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-6 5.3 Installing CPU and Heat Sink Caution: Be sure to observe all ESD precautio
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-7 6. Open the CPU lock by turning approximately ¼ turn counterclockwise. Lock a
TeamPoS 3000 XL and XL2 Installation 5-8 Issue 3 D900000145 10. Reinstall the motherboard (See Section 5.2). 11. Reinstall the front panel a
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-9 3. If hard disk is not already assembled attach hard disk drive to hard drive bra
TeamPoS 3000 XL and XL2 Installation 5-10 Issue 3 D900000145 5.5 Installing Memory (XL Motherboard only) Caution: Be sure to observe all
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-11 6. Check to make sure that both levers for the socket are locked into place.
TeamPoS 3000 XL and XL2 Installation 5-12 Issue 3 D900000145 5.6 Installing Memory (XL2 Memory) Caution: Be sure to observe all ESD preca
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-13 7. If two memory sticks are being installed, insert the 2nd stick in the top slo
Preface TeamPoS 3000 XL and XL2 ix Issue 3 D90000145 Table of Contents Preface ...
TeamPoS 3000 XL and XL2 Installation 5-14 Issue 3 D900000145 11. If this is an upgrade, install the upgrade label that comes with the upgrade
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-15 5.7. Installing the CD/DVD Drive Caution: Be sure to observe all ESD precautio
TeamPoS 3000 XL and XL2 Installation 5-16 Issue 3 D900000145 6. The CD/DVD drive comes already mounted onto a bracket. Align the slots in t
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-17 8. Attach the gray ribbon cable to the motherboard. The white power cable needs
TeamPoS 3000 XL and XL2 Installation 5-18 Issue 3 D900000145 5.8. Installing the Partial Backup Battery Caution: Be sure to observe all ES
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-19 5. Gently pull the white power cable for the battery out of the way and insert t
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-20 5.9. Removing the Backplane Assembly Caution: Be sure to observe all ESD preca
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-21 6. Slide the locking bar to the left and lift it out. The entire backplane asse
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-22 5.10. Installing PCI Add-In Card(s) Caution: Be sure to observe all ESD preca
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-23 8. Insert the PCI card into the slot and seat firmly. 9. Secure PCI card w
TeamPoS 3000 XL and XL2 Preface D90000145 Issue 3 x 4.4 Using Anti-static Protection ...
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-24 5.11. Installing the I/O Boards Caution: Be sure to observe all ESD precautio
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-25 5. I/O boards are connected to the backplane assembly. Refer to the instructions
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-26 5.11.2 Powered USB I/O Board Caution: Ports designated as Port C on the bac
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-27 The Powered USB I/O board has 3, 12V powered USB connections installed in the top
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-28 9. Flip the USB board over, slide it into the slots at the side of the top openi
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-29 5.11.3 Combo Board Caution: Be sure to observe all ESD precautions and power o
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-30 Caution: Ports designated as Port C on the backplane (24V PUSB) and Port 3 on t
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-31 8. Connect the narrow ribbon cable to port J12 on the backplane. 9. Flip co
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-32 10. Reattach the retainer clip and secure by pressing in the black plug.
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-33 5.11.4 Combo Board with COM Board (XL Motherboard only) (XL2 Motherboard does no
Preface TeamPoS 3000 XL and XL2 xi Issue 3 D90000145 6.1.1 General Care and Maintenance ...
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-34 6. Remove top filler plate by removing the black pin and retainer clip at the ce
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-35 9. Connect the narrow ribbon cable to port J12 on the backplane and to Combo ca
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-36 11. Connect the wide ribbon cable on the COM board to the ribbon socket on the C
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-37 14. Reattach the retainer clip and the black pin. 15. Ensure that all connec
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-38 5.12. Port Labels Port Identification COM3 COM4 COM1 COM2 COM7 CO
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-39 5.13. Standard Bracket Locations For stacked configurations, keyboard, printer,
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-40 Standard Unit showing Bracket Configuration for CT10 5.14. Installing the
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-41 5.14.1. Single Stacked LCD Stand Single Stacked LCD Stand 1. Remove o
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-42 4. Thread the cables through the stand beginning with the larger cables first.
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-43 7. Place the LCD face down on a clean dry surface. Remove the back cover by pre
TeamPoS 3000 XL and XL2 Preface D90000145 Issue 3 xii Chapter 8 Troubleshooting ...
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-44 Typical VGA Cabling
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-45 11. Replace the back of the monitor. The stand needs to be perpendicular to the
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-46 5.14.2 Single Dispersed LCD Stand 1. Remove only the hinge cap from the st
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-47 Audio (optional) pUSB VGA DVI Under back of Stand 3. Thread the cables through t
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-48 5. Place the LCD face down on a clean dry surface. Remove the back cover by pre
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-49 6. Attach the cables to the connectors on the LCD. Connector labels are etched
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-50 7. Attach the stand to the back of the LCD with the screws provided.
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-51 8. Replace the back of the monitor. The stand needs to be perpendicular to the
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-52
TeamPoS 3000 XL and XL2 Installation D900000145 Issue 3 5-53 5.14.3 Dual Stacked LCD Stand 1. Remove only the hinge caps and cable acc
Comments to this Manuals