Fujitsu RX2520 M1 Technical Information

Browse online or download Technical Information for Servers Fujitsu RX2520 M1. Fujitsu PRIMERGY RX2520 M1 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 360
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - Edition February 2014

Upgrade and Maintenance Manual - EnglishFUJITSU Server PRIMERGY RX2520 M1 Upgrade and Maintenance ManualEdition February 2014

Page 2 - Certified documentation

Upgrade and Maintenance Manual RX2520 M1Contents6.4.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 1046.5

Page 3 - Before reading this manual

100 Upgrade and Maintenance Manual RX2520 M1Power supply units6.3 Removing a hot-plug power supply unitINote for servers using CMA (Cable Management A

Page 4

RX2520 M1Upgrade and Maintenance Manual 101Power supply units6.3.2 Removing a hot-plug power supply unitFigure 18: Removing the hot-plug power supply

Page 5 - – CSS (Customer Self Service)

102 Upgrade and Maintenance Manual RX2520 M1Power supply units6.3.3 Installing a dummy coverFigure 19: Installing a dummy coverÊ Insert the dummy cove

Page 6 - Version history

RX2520 M1Upgrade and Maintenance Manual 103Power supply units6.4 Replacing a hot-plug power supply unitVCAUTION!●When replacing a power supply unit in

Page 7 - Contents

104 Upgrade and Maintenance Manual RX2520 M1Power supply units6.4.3 Installing the new hot-plug power supply unitFigure 20: Installing the hot-plug po

Page 8

RX2520 M1Upgrade and Maintenance Manual 105Power supply units6.5 Upgrading a power supply from 450 W to 800 WBasic informationVCAUTION!No mixed power

Page 9

106 Upgrade and Maintenance Manual RX2520 M1Power supply units6.5.3 Installing the new hot-plug power supply unitFigure 21: Installing the hot-plug po

Page 10 - RX2520 M1

RX2520 M1Upgrade and Maintenance Manual 107Power supply units6.5.4 Concluding stepsÊ "Connecting the server to the power source" on page 62Ê

Page 11

108 Upgrade and Maintenance Manual RX2520 M1Power supply units6.6.2 Disconnecting cablesFigure 22: Disconnecting cables from the power backplaneÊ Remo

Page 12

RX2520 M1Upgrade and Maintenance Manual 109Power supply unitsFigure 24: Removing the power backplane (B)Ê Fold the power backplane in the direction of

Page 13

RX2520 M1Upgrade and Maintenance ManualContents7.2.3 Removing 2.5-inch HDD / SSD modules . . . . . . . . . . . . 1247.2.3.1 Preliminary s

Page 14

110 Upgrade and Maintenance Manual RX2520 M1Power supply units6.6.4 Installing the power backplaneFigure 25: Installing the power backplane (A)Ê Inser

Page 15

RX2520 M1Upgrade and Maintenance Manual 111Power supply unitsFigure 26: Installing the power backplane (B)Ê Slide the power backplane downward in the

Page 16

112 Upgrade and Maintenance Manual RX2520 M1Power supply unitsFigure 27: Locking the power backplaneÊ Press the power backplane in the direction of th

Page 17

RX2520 M1Upgrade and Maintenance Manual 113Power supply units6.6.6 Concluding stepsÊ "Installing the air duct" on page 57Ê "Mounting th

Page 18

114 Upgrade and Maintenance Manual RX2520 M1Power supply units

Page 19

RX2520 M1Upgrade and Maintenance Manual 1157 Hard disk drives / solid state drivesSafety notesVCAUTION!●The hard disk drive must not be removed from t

Page 20

116 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drives7.1 Basic procedures– Solid state drives (SSDs) are always equipped b

Page 21 - 1 Introduction

RX2520 M1Upgrade and Maintenance Manual 117Hard disk drives / solid state drives7.2.1.1 HDD / SSD mounting order for 4x 2.5-inch HDD / SSD configurati

Page 22 - 1.1 Notational conventions

118 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drives7.2.1.3 HDD / SSD mounting order for 8x 2.5-inch HDD / SSD configurat

Page 23 - 2 Before you start

RX2520 M1Upgrade and Maintenance Manual 119Hard disk drives / solid state drives7.2.1.4 HDD / SSD naming scheme for 8x 2.5-inch HDD / SSD configuratio

Page 24

Upgrade and Maintenance Manual RX2520 M1Contents9 Expansion cards and backup units . . . . . . . . . . . . . 1499.1 Basic information

Page 25

120 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drives7.2.1.7 HDD / SSD mounting order for 16x 2.5-inch HDD / SSD configura

Page 26

RX2520 M1Upgrade and Maintenance Manual 121Hard disk drives / solid state drives7.2.1.8 HDD / SSD naming scheme 16x 2.5-inch HDD / SSD configurationIT

Page 27 - 2.2 Average task duration

122 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drives7.2.2.1 Preliminary stepsÊ Locate the correct drive bay as described

Page 28 - 2.3 Tools you need at hand

RX2520 M1Upgrade and Maintenance Manual 123Hard disk drives / solid state drives7.2.2.3 Installing a 2.5-inch HDD / SSD moduleFigure 36: Opening the 2

Page 29

124 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drivesÊ Insert the HDD module into a drive bay and carefully push back as f

Page 30

RX2520 M1Upgrade and Maintenance Manual 125Hard disk drives / solid state drivesIn order to permanently remove an operational HDD module that is part

Page 31

126 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drivesFigure 39: Removing a 2.5-inch HDD / SSD moduleÊ Pull the HDD / SSD m

Page 32

RX2520 M1Upgrade and Maintenance Manual 127Hard disk drives / solid state drivesFigure 40: Installing a 2.5-inch dummy moduleÊ Slide the dummy module

Page 33

128 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drives●Under no circumstances should you remove an HDD / SSD module while t

Page 34 - Before you start

RX2520 M1Upgrade and Maintenance Manual 129Hard disk drives / solid state drives7.3 Replacing SAS / SATA HDD / SSD backplanes7.3.1 Replacing the 4x 2.

Page 35 - 3 Important information

RX2520 M1Upgrade and Maintenance ManualContents9.4.2.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 1719.4.3 R

Page 36

130 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drives7.3.1.2 Removing the 4x 2.5-inch SAS HDD backplaneFigure 41: Disconne

Page 37

RX2520 M1Upgrade and Maintenance Manual 131Hard disk drives / solid state drives7.3.1.3 Installing the 4x 2.5-inch HDD SAS backplaneFigure 43: Install

Page 38

132 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drivesÊ Reconnect all cables to the 2.5-inch HDD SAS backplane:– Power cabl

Page 39

RX2520 M1Upgrade and Maintenance Manual 133Hard disk drives / solid state drivesÊ Remove all HDD / SSD modules from the server as described in section

Page 40

134 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drivesFigure 46: Removing the 2.5-inch HDD SAS backplane (A)Ê Remove the th

Page 41 - Figure 1: ESD label

RX2520 M1Upgrade and Maintenance Manual 135Hard disk drives / solid state drivesÊ At a slight angle, unhinge the 12x 2.5-inch HDD SAS backplane from t

Page 42

136 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drivesFigure 49: Fastening the 2.5-inch HDD SAS backplane (A)Ê Secure the 1

Page 43 - 3.3 CE conformity

RX2520 M1Upgrade and Maintenance Manual 137Hard disk drives / solid state drives– SAS cable C9 connected to SAS controller connector MLC1 to primary b

Page 44

138 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drivesFigure 51: Disconnecting cables from the 4x 2.5-inch HDD SAS backplan

Page 45 - 3.5 Environmental protection

RX2520 M1Upgrade and Maintenance Manual 139Hard disk drives / solid state drivesÊ Remove the screw.Ê Push the HDD cage out.7.4.2 Installing a HDD cage

Page 46

Upgrade and Maintenance Manual RX2520 M1Contents10.1.1.2 Independant Channel mode . . . . . . . . . . . . . . . . . 19810.1.1.3 Perfo

Page 47 - 4 Basic hardware procedures

140 Upgrade and Maintenance Manual RX2520 M1Hard disk drives / solid state drivesFigure 54: Reconnecting cables to the 4x 2.5-inch HDD SAS backplaneÊ

Page 48

RX2520 M1Upgrade and Maintenance Manual 1418 System fanSafety notesVCAUTION!●Do not damage or modify internal cables or devices. Doing so may cause a

Page 49 - 4.2 Shutting down the server

142 Upgrade and Maintenance Manual RX2520 M1System fan8.2 Replacing the system fan8.2.1 Preliminary stepsÊ "Locating the defective server" o

Page 50 - 4.3 Disconnecting power cords

RX2520 M1Upgrade and Maintenance Manual 143System fanÊ Take the system fan by the green touch points.Ê Lift the system fan out of the fan box.8.2.3 In

Page 51

144 Upgrade and Maintenance Manual RX2520 M1System fan8.3 Removing the fan box8.3.1 Preliminary stepsÊ "Locating the defective server" on pa

Page 52

RX2520 M1Upgrade and Maintenance Manual 145System fanFigure 58: Removing the fan boxÊ Remove the two screws.Figure 59: Removing the fan boxÊ Take the

Page 53

146 Upgrade and Maintenance Manual RX2520 M1System fan8.3.3 Installing the fan boxFigure 60: Installing the fan boxÊ Take the fan box by the green tou

Page 54 - 4.4.3 Opening the server

RX2520 M1Upgrade and Maintenance Manual 147System fanFigure 61: Installing the fan boxÊ Fasten the fan box with the 2 screws.Ê Install the two fan mod

Page 55

148 Upgrade and Maintenance Manual RX2520 M1System fan

Page 56

RX2520 M1Upgrade and Maintenance Manual 1499 Expansion cards and backup unitsSafety notesVCAUTION!●Do not damage or modify internal cables or devices.

Page 57 - 4.5 Reassembling

RX2520 M1Upgrade and Maintenance ManualContents11.5.2 Installing processor heat sinks . . . . . . . . . . . . . . . . . . 21911.5.2.1

Page 58 - 4.5.2 Closing the server

150 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsFigure 62: PCI slot overviewPCI slot TypeMechanical connectorElectrical in

Page 59

RX2520 M1Upgrade and Maintenance Manual 151Expansion cards and backup unitsExpansion card overview and installations sequenceSlot7: 1st Boot Slot Opti

Page 60

152 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsFor the latest information on supported expansion cards, refer your server

Page 61

RX2520 M1Upgrade and Maintenance Manual 153Expansion cards and backup units9.2 Handling slot brackets9.2.1 Installing a slot bracket9.2.1.1 Installing

Page 62

154 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsFigure 64: Installing a standard slot bracket (B)Ê Secure the slot bracket

Page 63

RX2520 M1Upgrade and Maintenance Manual 155Expansion cards and backup units9.2.1.2 Installing a slot bracket to the Network adapter D2755Figure 65: Ne

Page 64 - 4.7 Switching on the server

156 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsFigure 66: Network adapter D2755 - Mounting the slot bracket (B)Ê Secure t

Page 65 - 5 Basic software procedures

RX2520 M1Upgrade and Maintenance Manual 157Expansion cards and backup units9.2.1.3 Installing a slot bracket to the USB 3.0 interface card D3305VCAUTI

Page 66

158 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsFigure 69: Mounting the PCI slot bracket (B)Ê Secure the slot bracket to t

Page 67

RX2520 M1Upgrade and Maintenance Manual 159Expansion cards and backup units9.3 Expansion cards9.3.1 Installing expansion cards9.3.1.1 Preliminary step

Page 68

Upgrade and Maintenance Manual RX2520 M1Contents12.7 Replacing an ODD . . . . . . . . . . . . . . . . . . . . . . . 24412.7.1 P

Page 69

160 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup units9.3.1.2 Removing the slot bracketFigure 70: Removing the slot bracketÊ Rem

Page 70

RX2520 M1Upgrade and Maintenance Manual 161Expansion cards and backup unitsFigure 71: Installing the expansion cardÊ Carefully insert the expansion ca

Page 71

162 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsÊ If applicable, "Enabling Option ROM scan" on page 78.Ê "E

Page 72

RX2520 M1Upgrade and Maintenance Manual 163Expansion cards and backup unitsFigure 72: Removing an expansion cardÊ If applicable, "Removing an SFP

Page 73

164 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup units9.3.2.3 Installing a PCI slot bracketVCAUTION!Always replace slot brackets

Page 74

RX2520 M1Upgrade and Maintenance Manual 165Expansion cards and backup units9.3.3 Replacing expansion cardsNote on network settings recoveryIWhen repla

Page 75

166 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsÊ If the slot bracket on the defective expansion card is to be reused, rem

Page 76

RX2520 M1Upgrade and Maintenance Manual 167Expansion cards and backup units9.4 SAS RAID controller in PCI slot 79.4.1 Installing the SAS RAID controll

Page 77

168 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsÊ Place the controller on the mounting tabs on the slot bracket (1).Ê Secu

Page 78

RX2520 M1Upgrade and Maintenance Manual 169Expansion cards and backup units9.4.1.4 Connecting cables to the expansion cardÊ Connect SAS cables to the

Page 79

RX2520 M1Upgrade and Maintenance ManualContents12.13.3 Installing the new LTO drive . . . . . . . . . . . . . . . . . . . 27012.13.

Page 80

170 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup units9.4.2 Removing the SAS RAID controller9.4.2.1 Preliminary stepsÊ "Dis

Page 81

RX2520 M1Upgrade and Maintenance Manual 171Expansion cards and backup unitsÊ Loosen the screw on the RAID card holder (1).Ê Carefully pull up on the S

Page 82

172 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup units9.4.3 Replacing the SAS RAID controller9.4.3.1 Preliminary stepsÊ "Di

Page 83

RX2520 M1Upgrade and Maintenance Manual 173Expansion cards and backup units9.4.3.5 Connecting a backup unit to the expansion cardÊ If applicable, conn

Page 84

174 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup units9.5 Backup Units9.5.1 Basic informationThe Flash Backup Unit (FBU) backs u

Page 85

RX2520 M1Upgrade and Maintenance Manual 175Expansion cards and backup unitsVCAUTION!For further safety information, please refer to chapter "Impo

Page 86

176 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsFigure 80: Mounting the TFM kit (A)Ê Fit the spacer bolts on the TFM on SA

Page 87

RX2520 M1Upgrade and Maintenance Manual 177Expansion cards and backup unitsFigure 82: Installing the FBU in the FBU holder (B)Ê Ensure that the FBU is

Page 88

178 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup units9.5.2.5 Installing the FBU holder onto the air ductFigure 84: Installing t

Page 89

RX2520 M1Upgrade and Maintenance Manual 179Expansion cards and backup unitsFigure 86: Installing the FBU holder (C)Ê Insert the FBU holder into the ai

Page 90

Upgrade and Maintenance Manual RX2520 M1Contents14 System board and components . . . . . . . . . . . . . . . 29114.1 Basic informatio

Page 91

180 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup units9.5.2.6 Installing the air duct with an FBUFigure 87: Connecting the FBU t

Page 92

RX2520 M1Upgrade and Maintenance Manual 181Expansion cards and backup units9.5.3 Removing a FBUVCAUTION!Do not throw backup units into the trash can.

Page 93

182 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup units9.5.3.2 Removing the air duct with an FBUFigure 88: Disconnecting the FBU

Page 94

RX2520 M1Upgrade and Maintenance Manual 183Expansion cards and backup unitsÊ Lift up the green locking handle on the FBU holder (1) while sliding the

Page 95 - 6 Power supply units

184 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsÊ "Shutting down the server" on page 49Ê "Disconnecting pow

Page 96 - 6.1.2 Assembly rules

RX2520 M1Upgrade and Maintenance Manual 185Expansion cards and backup units9.5.4.4 Removing the FBU from the holderFigure 91: Removing the FBU from th

Page 97 - 6.2.1 Preliminary steps

186 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsÊ "Switching on the server" on page 64Ê If applicable, "Upd

Page 98

RX2520 M1Upgrade and Maintenance Manual 187Expansion cards and backup unitsÊ Remove the SFP+ transceiver module from its protective packaging.Ê Remove

Page 99 - 6.2.4 Concluding steps

188 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsInserting the SFP+ transceiver moduleFigure 94: Inserting the SFP+ transce

Page 100 - 6.3.1 Preliminary steps

RX2520 M1Upgrade and Maintenance Manual 189Expansion cards and backup unitsÊ Carefully fold up and latch the locking bail.Figure 96: Attaching the pro

Page 101 - RX2520 M1

RX2520 M1Upgrade and Maintenance ManualContents14.5.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 31514.5.

Page 102 - 6.3.4 Concluding steps

190 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsInstalling the secondary SFP+ transceiver moduleFigure 97: Installing the

Page 103 - 6.4.1 Preliminary steps

RX2520 M1Upgrade and Maintenance Manual 191Expansion cards and backup unitsFigure 98: Removing the protective optical port plugÊ If present, remove th

Page 104 - 6.4.4 Concluding steps

192 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup unitsFigure 99: Unlatching the locking bailÊ Carefully unlatch and fold down th

Page 105 - 6.5.1 Preliminary steps

RX2520 M1Upgrade and Maintenance Manual 193Expansion cards and backup units9.6.3 Replacing SFP+ transceiver modulesFor Fiber Channel over Ethernet (FC

Page 106

194 Upgrade and Maintenance Manual RX2520 M1Expansion cards and backup units

Page 107 - 6.5.4 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 19510 Main memorySafety notesVCAUTION!●Do not install unsupported third party memory modules. For further info

Page 108 - 6.6.2 Disconnecting cables

196 Upgrade and Maintenance Manual RX2520 M1Main memory10.1 Basic informationFigure 101: Memory overview– The system board is equipped with 12 memory

Page 109 - Ê Remove the power backplane

RX2520 M1Upgrade and Maintenance Manual 197Main memory10.1.1 Memory sequence10.1.1.1 Population rules– Populate memory slot 1 / channel A (DIMM 1A) fi

Page 110

198 Upgrade and Maintenance Manual RX2520 M1Main memory10.1.1.2 Independant Channel mode10.1.1.3 Performance modesNotes on Mirrored Channel and Perfor

Page 111

RX2520 M1Upgrade and Maintenance Manual 199Main memory10.2 Installing memory modules10.2.1 Preliminary stepsÊ "Disabling BitLocker functionality&

Page 112 - 6.6.5 Reconnecting cables

Copyright and TrademarksComments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedb

Page 113 - 6.6.6 Concluding steps

Upgrade and Maintenance Manual RX2520 M1Contents16.2.2 Memory board configuration table . . . . . . . . . . . . . . . 34616.2.3 Expan

Page 114

200 Upgrade and Maintenance Manual RX2520 M1Main memoryFigure 103: Installing memory modules (B)Ê Align the notch on the bottom of the module with the

Page 115

RX2520 M1Upgrade and Maintenance Manual 201Main memory10.3 Removing memory modules10.3.1 Preliminary stepsÊ "Disabling BitLocker functionality&qu

Page 116 - 7.1 Basic procedures

202 Upgrade and Maintenance Manual RX2520 M1Main memoryFigure 105: Removing memory modules (B)Ê Remove the ejected memory module.10.3.3 Concluding ste

Page 117 - Table 4: HDD naming scheme

RX2520 M1Upgrade and Maintenance Manual 203Main memoryÊ "Shutting down the server" on page 49.Ê "Disconnecting power cords" on pag

Page 118

204 Upgrade and Maintenance Manual RX2520 M1Main memory

Page 119 - Table 5: HDD naming scheme

RX2520 M1Upgrade and Maintenance Manual 20511 ProcessorsSafety notesVCAUTION!●Do not install unsupported processors. For further information on suppor

Page 120 - Table 6: HDD naming scheme

206 Upgrade and Maintenance Manual RX2520 M1Processors11.1 Basic informationThe system board D3169 offers two sockets for Intel Xeon processors.11.1.1

Page 121 - Table 7: HDD naming scheme

RX2520 M1Upgrade and Maintenance Manual 207Processors11.2 Installing processorsVCAUTION!Processors are extremely sensitive to electrostatic discharge

Page 122

208 Upgrade and Maintenance Manual RX2520 M1Processors11.2.2.1 Removing the protective coverFigure 107: Opening socket release leverÊ Unlatch the sock

Page 123

RX2520 M1Upgrade and Maintenance Manual 209ProcessorsFigure 109: Removing the protective coverÊ Remove the black protective cover from the processor s

Page 124

RX2520 M1Upgrade and Maintenance Manual 211 IntroductionThis Upgrade and Maintenance Manual provides instructions for the following procedures:●Upgrad

Page 125

210 Upgrade and Maintenance Manual RX2520 M1ProcessorsIMake sure that the recesses on the processor are aligned with the corresponding markings on the

Page 126

RX2520 M1Upgrade and Maintenance Manual 211ProcessorsFigure 112: Closing the socket release leverÊ Close the socket release lever (1) and latch it und

Page 127

212 Upgrade and Maintenance Manual RX2520 M1Processors11.3 Removing processors11.3.1 Preliminary stepsÊ "Disabling BitLocker functionality"

Page 128

RX2520 M1Upgrade and Maintenance Manual 213ProcessorsFigure 113: Opening socket release leverÊ Unlatch the socket release lever by pushing it down and

Page 129

214 Upgrade and Maintenance Manual RX2520 M1ProcessorsFigure 115: Removing the processorÊ Carefully remove the defective processor from its socket in

Page 130

RX2520 M1Upgrade and Maintenance Manual 215Processors11.3.2.1 Installing the protective coverFigure 116: Attaching the protective socket coverÊ Carefu

Page 131

216 Upgrade and Maintenance Manual RX2520 M1ProcessorsFigure 118: Close the socket release leverÊ Close the socket release (1) lever and latch it unde

Page 132

RX2520 M1Upgrade and Maintenance Manual 217ProcessorsVCAUTION!Processors are extremely sensitive to electrostatic discharge and must be handled with c

Page 133

218 Upgrade and Maintenance Manual RX2520 M1ProcessorsÊ "Reassembling" on page 57Ê "Connecting the server to the power source" on

Page 134

RX2520 M1Upgrade and Maintenance Manual 219Processors11.5 Handling processor heat sinks11.5.1 Preliminary stepsÊ "Shutting down the server"

Page 135

22 Upgrade and Maintenance Manual RX2520 M1Introduction1.1 Notational conventionsThe following notational conventions are used in this manual:Text in

Page 136

220 Upgrade and Maintenance Manual RX2520 M1Processors11.5.2.1 Preparing the heat sink and processorWhen installing a new heat sinkFigure 120: Removin

Page 137 - 7.4 HDD cage

RX2520 M1Upgrade and Maintenance Manual 221Processors11.5.2.2 Installing the heat sinkFigure 121: Installing the heat sinkÊ Align the heat sink with t

Page 138 - – Power cables

222 Upgrade and Maintenance Manual RX2520 M1Processors11.5.3 Removing processor heat sinksFigure 122: Removing the processor heat sink (A)Ê Loosen the

Page 139 - 7.4.2 Installing a HDD cage

RX2520 M1Upgrade and Maintenance Manual 223ProcessorsFigure 123: Removing the processor heat sink (B)Ê Carefully turn the heat sink back and forth to

Page 140

224 Upgrade and Maintenance Manual RX2520 M1Processors11.5.4.2 Applying thermal pasteÊ Apply thermal paste to the processor surface as described in se

Page 141 - 8 System fan

RX2520 M1Upgrade and Maintenance Manual 225Processors11.6 Applying thermal pasteI– For the Japanese market, the service engineer must follow the instr

Page 142 - 8.2 Replacing the system fan

226 Upgrade and Maintenance Manual RX2520 M1ProcessorsFigure 125: Applying thermal pasteÊ Apply a dot of thermal paste to the center of the processor

Page 143 - 8.2.4 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 22712 Accessible drivesSafety notesVCAUTION!●Before installing an accessible drive, acquaint yourself with the

Page 144 - 8.3 Removing the fan box

228 Upgrade and Maintenance Manual RX2520 M1Accessible drives12.1 Basic informationsMounting order for accessible drives in the front panel cagePRIMER

Page 145 - Ê Remove the two screws

RX2520 M1Upgrade and Maintenance Manual 229Accessible drivesFigure 128: Accessible drive (RDX) in HDD bay for 2.5-in HDD version12.2 Installing a Loca

Page 146 - 8.3.3 Installing the fan box

RX2520 M1Upgrade and Maintenance Manual 232 Before you startBefore you start any upgrade or maintenance task, please proceed as follows:Ê Carefully re

Page 147 - 8.3.4 Concluding steps

230 Upgrade and Maintenance Manual RX2520 M1Accessible drives12.2.2 Removing the LSD dummy coverFigure 129: Removing the LSD dummy coverÊ Take the LSD

Page 148

RX2520 M1Upgrade and Maintenance Manual 231Accessible drives12.2.3 Installing a LSD moduleFigure 130: Installing the LSD moduleÊ Insert the LSD module

Page 149 - 9 Expansion cards and backup

232 Upgrade and Maintenance Manual RX2520 M1Accessible drives12.2.4 Concluding stepsÊ "Installing the fan box" on page 146Ê "Reassembli

Page 150

RX2520 M1Upgrade and Maintenance Manual 233Accessible drives12.3.2 Removing the LSD moduleFigure 132: Removing the LSD cableÊ Remove the LSD cable fro

Page 151

234 Upgrade and Maintenance Manual RX2520 M1Accessible drivesFigure 133: Unlocking the LSD moduleÊ Press in on the locking latch to disengage the LSD

Page 152

RX2520 M1Upgrade and Maintenance Manual 235Accessible drivesFigure 135: Insert the LSD dummy coverÊ Insert the LSD dummy cover into the bay.12.3.3 Con

Page 153 - 9.2 Handling slot brackets

236 Upgrade and Maintenance Manual RX2520 M1Accessible drives12.4.1 Preliminary stepsÊ "Disabling BitLocker functionality" on page 65Ê "

Page 154

RX2520 M1Upgrade and Maintenance Manual 237Accessible drives12.5.1 Preliminary stepsÊ "Disabling BitLocker functionality" on page 65Ê "

Page 155

238 Upgrade and Maintenance Manual RX2520 M1Accessible drivesFigure 137: Removing the dummy moduleÊ Pull the ODD dummy module out.12.5.3 Preparing an

Page 156

RX2520 M1Upgrade and Maintenance Manual 239Accessible drivesÊ Take the ODD latch from its place on the bottom of the front panel module.IFor the Japan

Page 157

24 Upgrade and Maintenance Manual RX2520 M1Before you startIFor the latest information on hardware options, refer to your server’s hardware configurat

Page 158 - 9.2.2 Removing a slot bracket

240 Upgrade and Maintenance Manual RX2520 M1Accessible drives12.5.4 Installing an ODDFigure 140: Installing the ODDÊ Insert the ODD into the bay and p

Page 159 - 9.3 Expansion cards

RX2520 M1Upgrade and Maintenance Manual 241Accessible drivesFigure 141: Installing the ODDÊ Run the SATA and power cables through the ODD bay opening

Page 160

242 Upgrade and Maintenance Manual RX2520 M1Accessible drives12.6 Removing the optical disc drive (ODD)12.6.1 Preliminary stepsÊ Ask the system admini

Page 161

RX2520 M1Upgrade and Maintenance Manual 243Accessible drivesÊ Disconnect the SATA cable (1) and the power cable (2).Ê Pull the locking latch upward to

Page 162

244 Upgrade and Maintenance Manual RX2520 M1Accessible drivesFigure 144: Installing the ODD dummy moduleÊ Insert the ODD dummy module.12.6.3 Concludin

Page 163 - Ê Remove the screw

RX2520 M1Upgrade and Maintenance Manual 245Accessible drives12.7.1 Preliminary stepsÊ Ask the system administrator to eject all remaining backup or op

Page 164

246 Upgrade and Maintenance Manual RX2520 M1Accessible drives12.8 Installing a RDX drive in 2.5-inch versionINotes on RDX drive USB cabling:– A USB 2.

Page 165

RX2520 M1Upgrade and Maintenance Manual 247Accessible drivesFigure 145: Inserting the RDX drive in the drive cageÊ Insert the RDX drive into the bay a

Page 166

248 Upgrade and Maintenance Manual RX2520 M1Accessible drives12.8.3 Installing the RDX driveFigure 147: Installing the RDX driveÊ Insert the RDX with

Page 167

RX2520 M1Upgrade and Maintenance Manual 249Accessible drives12.8.4 Connecting the RDX drive12.8.4.1 Connecting the RDX drive to the system boardFigure

Page 168

RX2520 M1Upgrade and Maintenance Manual 25Before you start2.1 Classification of proceduresThe complexity of maintenance procedures varies significantl

Page 169

250 Upgrade and Maintenance Manual RX2520 M1Accessible drivesFigure 149: Installing the RDX drive cageÊ Fasten the drive cage with the screw.Figure 1

Page 170

RX2520 M1Upgrade and Maintenance Manual 251Accessible drives12.8.5 Concluding stepsÊ "Installing the fan box" on page 146Ê "Reassemblin

Page 171

252 Upgrade and Maintenance Manual RX2520 M1Accessible drivesFigure 151: Removing the cables from the RDX driveÊ Removing the screw that fasten the dr

Page 172

RX2520 M1Upgrade and Maintenance Manual 253Accessible drives12.9.3 Removing a RDX drive out of the cageFigure 153: Removing the 4 screwsÊ Remove the 4

Page 173

254 Upgrade and Maintenance Manual RX2520 M1Accessible drivesFigure 154: Installing tape drive dummy coverÊ Insert the tape drive dummy cover into the

Page 174 - 9.5 Backup Units

RX2520 M1Upgrade and Maintenance Manual 255Accessible drivesÊ Fasten the tape drive dummy module with 2 screws.Ê Insert the drive cage into bay 2, for

Page 175

256 Upgrade and Maintenance Manual RX2520 M1Accessible drivesÊ "Disconnecting power cords" on page 50Ê "Getting access to the component

Page 176

RX2520 M1Upgrade and Maintenance Manual 257Accessible drives12.11.1 Preliminary stepsÊ "Disabling BitLocker functionality" on page 65Ê "

Page 177

258 Upgrade and Maintenance Manual RX2520 M1Accessible drivesFigure 157: Removing the cover plateÊ Remove the cover plate.12.11.3 Removing the tape dr

Page 178

RX2520 M1Upgrade and Maintenance Manual 259Accessible drivesÊ Remove the four screws.Ê Pull out the tape drive dummy module.12.11.4 Installing an LTO

Page 179

26 Upgrade and Maintenance Manual RX2520 M1Before you start2.1.2 Upgrade and Repair Units (URU)Upgrade and Repair Units are non hot-plug components th

Page 180

260 Upgrade and Maintenance Manual RX2520 M1Accessible drivesFigure 160: Fastening the LTO drive in the drive cageÊ Fasten the LTO drive with 4 screws

Page 181 - 9.5.3 Removing a FBU

RX2520 M1Upgrade and Maintenance Manual 261Accessible drivesFigure 161: Connecting the cover plateÊ Connect the cover plate to the LTO drive.12.11.5 I

Page 182

262 Upgrade and Maintenance Manual RX2520 M1Accessible drivesÊ Push the LTO cage into the bay.Figure 163: Connecting the cables to the LTOÊ Fasten the

Page 183 - 9.5.4 Replacing a FBU

RX2520 M1Upgrade and Maintenance Manual 263Accessible drives12.12 Removing an LTO drive in 2.5-inch version12.12.1 Preliminary stepsÊ "Disabling

Page 184

264 Upgrade and Maintenance Manual RX2520 M1Accessible drives12.12.2 Removing the drive cageFigure 164: Unlocking the drive cageÊ Remove the screw tha

Page 185

RX2520 M1Upgrade and Maintenance Manual 265Accessible drives12.12.3 Removing an LTO drive out of the cageFigure 166: Removing the cover plateÊ Remove

Page 186

266 Upgrade and Maintenance Manual RX2520 M1Accessible drivesÊ Remove the four screws.Figure 168: Removing the LTO driveÊ Pull the LTO drive out.

Page 187

RX2520 M1Upgrade and Maintenance Manual 267Accessible drives12.12.4 Installing the tape drive dummy moduleFigure 169: Installing the tape drive dummy

Page 188

268 Upgrade and Maintenance Manual RX2520 M1Accessible drivesÊ Fasten the tape drive dummy module in the drive cage with 4 screws.Figure 171: Installi

Page 189

RX2520 M1Upgrade and Maintenance Manual 269Accessible drivesÊ Push the drive cage in.Ê Fasten the drive cage with the screw see also "Installing

Page 190

RX2520 M1Upgrade and Maintenance Manual 27Before you start2.1.3 Field Replaceable Units (FRU)Removing and installing Field Replaceable Units involves

Page 191

270 Upgrade and Maintenance Manual RX2520 M1Accessible drives12.13 Replacing the LTO drive in 2.5-inch version12.13.1 Preliminary stepsÊ "Disabli

Page 192

RX2520 M1Upgrade and Maintenance Manual 271Accessible drivesÊ "Reassembling" on page 57Ê "Connecting the server to the power source&quo

Page 193

272 Upgrade and Maintenance Manual RX2520 M1Accessible drives

Page 194

RX2520 M1Upgrade and Maintenance Manual 27313 Front panel and external connectorsSafety notesVCAUTION!●When inserting the front panel module into the

Page 195 - 10 Main memory

274 Upgrade and Maintenance Manual RX2520 M1Front panel and external connectorsTo avoid the loss of non-default settings when replacing the system boa

Page 196 - 10.1 Basic information

RX2520 M1Upgrade and Maintenance Manual 275Front panel and external connectors13.1.1.2 Removing the front panel moduleFigure 173: Disconnecting the fr

Page 197 - 10.1.1 Memory sequence

276 Upgrade and Maintenance Manual RX2520 M1Front panel and external connectorsFigure 174: Connecting the front panel cable to the front panel moduleÊ

Page 198

RX2520 M1Upgrade and Maintenance Manual 277Front panel and external connectorsFigure 176: Connecting front panel cablesÊ Connect the front panel cable

Page 199 - 10.2.1 Preliminary steps

278 Upgrade and Maintenance Manual RX2520 M1Front panel and external connectorsÊ "Enabling SVOM boot watchdog functionality" on page 82Ê &qu

Page 200 - 10.2.3 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 279Front panel and external connectors13.2.1.3 Preparing the front panel moduleFigure 177: Breaking out the fr

Page 201 - 10.3 Removing memory modules

28 Upgrade and Maintenance Manual RX2520 M1Before you start2.3 Tools you need at handWhen preparing the maintenance task, ensure that all required too

Page 202 - 10.4 Replacing memory modules

280 Upgrade and Maintenance Manual RX2520 M1Front panel and external connectorsFigure 179: Mounting the front VGA connectorÊ Insert the front VGA conn

Page 203 - 10.4.4 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 281Front panel and external connectorsFigure 180: Connecting front panel cablesÊ Connect the front VGA cable t

Page 204 - Main memory

282 Upgrade and Maintenance Manual RX2520 M1Front panel and external connectors13.2.2 Removing the front VGA connector13.2.2.1 Preliminary stepsÊ &quo

Page 205 - 11 Processors

RX2520 M1Upgrade and Maintenance Manual 283Front panel and external connectors13.2.2.3 Removing the front VGA connectorFigure 182: Removing front VGA

Page 206 - 11.1 Basic information

284 Upgrade and Maintenance Manual RX2520 M1Front panel and external connectors13.2.3 Replacing the front VGA connector13.2.3.1 Preliminary stepsÊ &qu

Page 207 - 11.2 Installing processors

RX2520 M1Upgrade and Maintenance Manual 285Front panel and external connectorsÊ "Reassembling" on page 57Ê "Connecting the server to th

Page 208

286 Upgrade and Maintenance Manual RX2520 M1Front panel and external connectorsMulticageFigure 183: Removing the multicageÊ Remove the two screws.Ê Pu

Page 209

RX2520 M1Upgrade and Maintenance Manual 287Front panel and external connectorsPanelhousingFigure 184: Removing the panelhousingÊ Remove the screw.Ê Pu

Page 210

288 Upgrade and Maintenance Manual RX2520 M1Front panel and external connectorsFigure 185: Inserting the front panel cageÊ Insert the front panel cage

Page 211 - 11.2.3 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 289Front panel and external connectors13.3.1.4 Concluding stepsÊ Connect all cables from the modules that are

Page 212 - 11.3 Removing processors

RX2520 M1Upgrade and Maintenance Manual 29Before you startScrew driver / Bit insert / torqueScrew Usage TypeHexagonal cross SW50.6 NmHDD cages to ch

Page 213

290 Upgrade and Maintenance Manual RX2520 M1Front panel and external connectors

Page 214

RX2520 M1Upgrade and Maintenance Manual 29114 System board and componentsSafety notesVCAUTION!●Devices and components inside the server remain hot aft

Page 215

292 Upgrade and Maintenance Manual RX2520 M1System board and componentsThe onboard SAS enabling key enables the SAS functionality of the Onboard contr

Page 216 - 11.3.3 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 293System board and components14.2.2 Removing the batteryFigure 187: Replacing the CMOS batteryÊ Press out on

Page 217 - 11.4.3 Concluding steps

294 Upgrade and Maintenance Manual RX2520 M1System board and components14.2.3 Installing the CMOS batteryFigure 188: Installing the CMOS batteryÊ At a

Page 218

RX2520 M1Upgrade and Maintenance Manual 295System board and componentsÊ "Switching on the server" on page 64Ê "Verifying system informa

Page 219 - 11.5.1 Preliminary steps

296 Upgrade and Maintenance Manual RX2520 M1System board and components14.3.1.2 Installing the UFMFigure 189: UFM kitFigure 190: UFM mounting location

Page 220

RX2520 M1Upgrade and Maintenance Manual 297System board and componentsFigure 191: Installing the UFMÊ Connect the UFM to the system board, snapping in

Page 221

298 Upgrade and Maintenance Manual RX2520 M1System board and componentsÊ The server should now boot from the "Recovery Tool CD".Ê Follow the

Page 222 - Processors

RX2520 M1Upgrade and Maintenance Manual 299System board and components14.3.2.2 Removing the UFMFigure 192: Removing the UFM (A)Ê Remove the nylon scre

Page 223

RX2520 M1Upgrade and Maintenance Manual Before reading this manualFor your safetyThis manual contains important information for safely and correctly

Page 224 - 11.5.5 Concluding steps

30 Upgrade and Maintenance Manual RX2520 M1Before you startCross0.2 NmODD latch (delivered with the accessory pack)M2 x 5 mm (silver)C26192-Y10-C63Cyl

Page 225 - 11.6 Applying thermal paste

300 Upgrade and Maintenance Manual RX2520 M1System board and components14.3.3.1 Preliminary stepsÊ "Disabling BitLocker functionality" on pa

Page 226

RX2520 M1Upgrade and Maintenance Manual 301System board and componentsÊ Remove the UFM spacer (2).Figure 194: Installing the UFM (B)Ê Fit the new UFM

Page 227 - 12 Accessible drives

302 Upgrade and Maintenance Manual RX2520 M1System board and componentsFigure 195: Destroying the defective UFMÊ Use a pair of combination pliers (1)

Page 228 - 12.1 Basic informations

RX2520 M1Upgrade and Maintenance Manual 303System board and components14.3.3.4 Concluding stepsÊ "Installing the air duct" on page 57Ê "

Page 229 - 12.2.1 Preliminary steps

304 Upgrade and Maintenance Manual RX2520 M1System board and components14.4 Trusted Platform Module (TPM)14.4.1 Installing the TPM14.4.1.1 Preliminary

Page 230

RX2520 M1Upgrade and Maintenance Manual 305System board and components14.4.1.2 Installing the TPMFigure 196: TPM kitFigure 197: TPM mounting location1

Page 231

306 Upgrade and Maintenance Manual RX2520 M1System board and componentsFigure 198: Installing the TPM spacerÊ Snap the TPM spacer into the cut-out in

Page 232 - 12.3 Removing a LSD module

RX2520 M1Upgrade and Maintenance Manual 307System board and componentsFigure 200: Securing the TPMÊ Connect the new TPM to the system board.Ê Secure t

Page 233 - Accessible drives

308 Upgrade and Maintenance Manual RX2520 M1System board and componentsÊ Set the TPM Support and TPM State settings to Enabled.Ê Under Pending TPM ope

Page 234

RX2520 M1Upgrade and Maintenance Manual 309System board and components14.4.2 Removing the TPMVCAUTION!Advise your contact persons that they must provi

Page 235 - 12.4 Replacing a LSD module

RX2520 M1Upgrade and Maintenance Manual 31Before you start2.4 Documents you need at handMaintenance procedures may include references to additional do

Page 236 - 12.4.4 Concluding steps

310 Upgrade and Maintenance Manual RX2520 M1System board and components14.4.2.1 Preliminary stepsÊ Before removing the TPM, it is necessary to remove

Page 237 - 12.5.1 Preliminary steps

RX2520 M1Upgrade and Maintenance Manual 311System board and componentsÊ Save your changes and exit the BIOS.IFor detailed information on how to access

Page 238 - 12.5.3 Preparing an ODD

312 Upgrade and Maintenance Manual RX2520 M1System board and componentsÊ Carefully loosen the TPM screw using a thin slotted screw driver (e.g. watchm

Page 239

RX2520 M1Upgrade and Maintenance Manual 313System board and components14.4.2.3 Concluding stepsÊ "Installing the fan box" on page 146Ê "

Page 240 - 12.5.4 Installing an ODD

314 Upgrade and Maintenance Manual RX2520 M1System board and componentsÊ "Locating the defective server" on page 47Ê "Shutting down the

Page 241 - 12.5.5 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 315System board and components14.4.3.4 Concluding stepsÊ "Installing the fan box" on page 146Ê "

Page 242 - 12.6.2 Removing the ODD

316 Upgrade and Maintenance Manual RX2520 M1System board and components14.5.1.2 Installing the onboard SAS enabling keyFigure 204: onboard SAS enablin

Page 243

RX2520 M1Upgrade and Maintenance Manual 317System board and components14.5.1.3 Concluding stepsÊ "Reassembling" on page 57Ê "Connecting

Page 244 - 12.7 Replacing an ODD

318 Upgrade and Maintenance Manual RX2520 M1System board and components14.5.2.2 Removing onboard SAS enabling keyFigure 206: onboard SAS enabling key

Page 245 - 12.7.4 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 319System board and components14.5.3.1 Preliminary stepsÊ "Disabling BitLocker functionality" on pag

Page 246 - 12.8.1 Preliminary steps

32 Upgrade and Maintenance Manual RX2520 M1Before you start"Safety notes and regulations" manual " 安全上のご注意" for the Japanese marke

Page 247

320 Upgrade and Maintenance Manual RX2520 M1System board and componentsNote on TPMIThe system board can be equipped with an optional TPM (Trusted Plat

Page 248

RX2520 M1Upgrade and Maintenance Manual 321System board and componentsIf the contact persons DO NOT have a backup copy available, inform them that rep

Page 249

322 Upgrade and Maintenance Manual RX2520 M1System board and components14.6.1 Preliminary stepsÊ "Note on network settings recovery" on page

Page 250

RX2520 M1Upgrade and Maintenance Manual 323System board and components14.6.2 Removing the defective system boardÊ Remove all cables from the system bo

Page 251 - 12.9.1 Preliminary steps

324 Upgrade and Maintenance Manual RX2520 M1System board and componentsFigure 207: Detaching the system boardÊ Remove 11 screws from the system board

Page 252

RX2520 M1Upgrade and Maintenance Manual 325System board and componentsFigure 208: Removing the system boardÊ Slightly lift up the system board by the

Page 253

326 Upgrade and Maintenance Manual RX2520 M1System board and components14.6.3 Installing the system board14.6.3.1 Mounting the system boardFigure 209:

Page 254

RX2520 M1Upgrade and Maintenance Manual 327System board and componentsFigure 210: Securing the system boardÊ Secure the system board with 11 screws (M

Page 255 - 12.10.1 Preliminary steps

328 Upgrade and Maintenance Manual RX2520 M1System board and componentsRemoving processors from the defective system boardÊ Carefully remove the proce

Page 256 - 12.10.4 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 329System board and components– UFM: install the UFM spacer to the system board and install the UFM see sectio

Page 257 - 12.11.1 Preliminary steps

RX2520 M1Upgrade and Maintenance Manual 33Before you startAdditional documentation– "iRMC S4" user guide available online– RAID documentatio

Page 258 - Ê Remove the cover plate

330 Upgrade and Maintenance Manual RX2520 M1System board and components

Page 259 - Ê Remove the four screws

RX2520 M1Upgrade and Maintenance Manual 33115 CablesThis chapter provides information on how to connect, disconnect and route cables.Safety notesVCAUT

Page 260

332 Upgrade and Maintenance Manual RX2520 M1CablesC7CBL SAS 2XMINI 110T26139-Y3963-V1114x 2.5-inch SAS BP to 12x2.5-inch SAS BPoC8CBL SAS 2XMINI 320T2

Page 261

RX2520 M1Upgrade and Maintenance Manual 333CablesC22 CBL USB3.0AN 0,8MT26139- Y4039-A80USB3.0 cable for RDX3.0 drive o No NameCable numberRoutin

Page 262 - 12.11.6 Concluding steps

334 Upgrade and Maintenance Manual RX2520 M1Cables15.2 Cabling plans15.2.1 Configuration 24x 2.5-inch HDD model with onboard SAS/SATA controllerFigure

Page 263 - 12.12.1 Preliminary steps

RX2520 M1Upgrade and Maintenance Manual 335Cables4x 2.5-inch HDD model with SAS controllerFigure 212: Cabling - 4x 2.5-inch HDD model with SAS control

Page 264

336 Upgrade and Maintenance Manual RX2520 M1Cables15.2.2 Configuration 34x 2.5-inch HDD model with LTO driveFigure 213: Cabling - 4x 2.5-inch HDD mode

Page 265

RX2520 M1Upgrade and Maintenance Manual 337Cables15.2.3 Configuration 48x 2.5-inch HDD modelFigure 214: Cabling - 8x 2.5-inch HDD modelODD (opt.) SAS

Page 266 - Ê Pull the LTO drive out

338 Upgrade and Maintenance Manual RX2520 M1Cables15.2.4 Configuration 58x 2.5-inch HDD model with optional RDX drive via onboard contr. (USB2.0)Figur

Page 267

RX2520 M1Upgrade and Maintenance Manual 339Cables8x2.5-inch HDD model with optional RDX drive via interface card (USB 3.0)Figure 216: Cabling - 8x 2.5

Page 268 - Ê Fasten the cover plate

34 Upgrade and Maintenance Manual RX2520 M1Before you start

Page 269 - 12.12.5 Concluding steps

340 Upgrade and Maintenance Manual RX2520 M1Cables15.2.5 Configuration 68x 2.5-inch HDD model with LTO tape driveFigure 217: Cabling - 8x 2.5-inch HDD

Page 270 - 12.13.4 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 341Cables15.2.6 Configuration 712x 2.5-inch HDD modelFigure 218: Cabling - 12x2.5-inch HDD modelODD (opt.) SA

Page 271

342 Upgrade and Maintenance Manual RX2520 M1Cables15.2.7 Configuration 816x 2.5-inch HDD modelFigure 219: Cabling - 16x 2.5-inch HDD modelSAS BP 4 x 2

Page 272

RX2520 M1Upgrade and Maintenance Manual 34316 Appendix16.1 Mechanical overview16.1.1 Server frontFigure 220: Server front sidePos. Component1 LSD modu

Page 273 - 13 Front panel and external

344 Upgrade and Maintenance Manual RX2520 M1Appendix16.1.2 Server rearFigure 221: PRIMERGY RX2520 M1 rearPos. Component1 Power supply unit 2 Optional

Page 274

RX2520 M1Upgrade and Maintenance Manual 345Appendix16.1.3 Server interiorFigure 222: PRIMERGY RX2520 M1 interior (example: 2.5-inch HDD model)Pos. Co

Page 275

346 Upgrade and Maintenance Manual RX2520 M1Appendix16.2 Configuration tables16.2.1 Hard disk drives / solid state drives mounting orderPlease refer t

Page 276

RX2520 M1Upgrade and Maintenance Manual 347Appendix16.3 Connectors and indicators16.3.1 Connectors and indicators on the system board16.3.1.1 Onboard

Page 277

348 Upgrade and Maintenance Manual RX2520 M1AppendixNo. Print Description1 PWR CTRL Power management connector2 PWR ATX power supply connector3 PWR HD

Page 278 - 13.2 Front VGA connector

RX2520 M1Upgrade and Maintenance Manual 349Appendix16.3.1.2 Onboard indicators and controlsFigure 224: Onboard indicators and Indicate CSS buttonCompo

Page 279 - Figure 178: Front VAG cable

RX2520 M1Upgrade and Maintenance Manual 353 Important informationVCAUTION!Before installing and starting up a device, please observe the safety instru

Page 280

350 Upgrade and Maintenance Manual RX2520 M1Appendix16.3.2 Connectors and indicators on the I/O panel16.3.2.1 I/O panel connectorsFigure 225: PRIMERGY

Page 281

RX2520 M1Upgrade and Maintenance Manual 351AppendixDepending on BIOS settings, the shared LAN connector may also be used as a management LAN connector

Page 282

352 Upgrade and Maintenance Manual RX2520 M1AppendixINote on the onboard LAN controllerThe system board is equipped with a Gigabit Ethernet Controller

Page 283

RX2520 M1Upgrade and Maintenance Manual 353Appendix16.3.3 Connectors and indicators on the front panel16.3.3.1 Front panel connectorsFigure 227: Front

Page 284

354 Upgrade and Maintenance Manual RX2520 M1Appendix16.3.3.2 Front panel controls and indicatorsFigure 228: Front side: indicators and controls1 HDD/S

Page 285 - 13.3 Front cage

RX2520 M1Upgrade and Maintenance Manual 355AppendixLocal diagnostic indicatorsIIn addition to local dignostic indicators, CSS or Global Error LEDs ind

Page 286

356 Upgrade and Maintenance Manual RX2520 M1Appendix11Global error indicatoroff no critical event (non CSS component)orange onprefailure detected (non

Page 287

RX2520 M1Upgrade and Maintenance Manual 357AppendixButtonsPos. Button Function4 ID buttonThis button highlights the ID indicator on the front and I/O

Page 288

358 Upgrade and Maintenance Manual RX2520 M1Appendix16.4 Onboard settingsFigure 229: Onboard settings on system board D3169CPU 1CPU 2external connecto

Page 289

RX2520 M1Upgrade and Maintenance Manual 359Appendix16.5 Minimum startup configurationIf the server does not start up or other problems occur, it may b

Page 290

36 Upgrade and Maintenance Manual RX2520 M1Important information●If the device is brought in from a cold environment, condensation may form both insid

Page 291 - 14.1 Basic information

360 Upgrade and Maintenance Manual RX2520 M1AppendixÊ "Shutting down the server" on page 49Ê "Disconnecting power cords" on page 5

Page 292 - 14.2.1 Preliminary steps

RX2520 M1Upgrade and Maintenance Manual 37Important information●Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards or ISO/IEC 118

Page 293 - 14.2.2 Removing the battery

38 Upgrade and Maintenance Manual RX2520 M1Important information●Do not damage or modify internal cables or devices. Doing so may cause a device failu

Page 294 - 14.2.4 Concluding steps

RX2520 M1Upgrade and Maintenance Manual 39Important informationWorking with optical disk drives and mediaWhen working with optical disk drives, these

Page 295 - 14.3 USB Flash Module (UFM)

Upgrade and Maintenance Manual RX2520 M1These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, ai

Page 296 - Figure 189: UFM kit

40 Upgrade and Maintenance Manual RX2520 M1Important information●Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty,

Page 297

RX2520 M1Upgrade and Maintenance Manual 41Important informationModules with Electrostatic-Sensitive DevicesModules with electrostatic-sensitive device

Page 298 - 14.3.2 Removing the UFM

42 Upgrade and Maintenance Manual RX2520 M1Important informationTransporting the server●Only transport the server in its original packaging or in pack

Page 299 - 14.3.3 Replacing the UFM

RX2520 M1Upgrade and Maintenance Manual 43Important information3.2 ENERGY STAR3.3 CE conformityProducts that have been certified compliant with ENERGY

Page 300

44 Upgrade and Maintenance Manual RX2520 M1Important information3.4 FCC Class A Compliance StatementIf there is an FCC statement on the device, it app

Page 301

RX2520 M1Upgrade and Maintenance Manual 45Important information3.5 Environmental protectionEnvironmentally-friendly product design and developmentThis

Page 302 - System board and components

46 Upgrade and Maintenance Manual RX2520 M1Important informationLabels on plastic casing partsPlease avoid sticking your own labels on plastic parts w

Page 303

RX2520 M1Upgrade and Maintenance Manual 474 Basic hardware procedures4.1 Using diagnostics informationUse the Fujitsu ServerView Suite management soft

Page 304 - 14.4.1 Installing the TPM

48 Upgrade and Maintenance Manual RX2520 M1Basic hardware procedures4.1.2 Determining the error classThe Local Service Concept (LSC) allows you to ide

Page 305 - Figure 196: TPM kit

RX2520 M1Upgrade and Maintenance Manual 49Basic hardware procedures4.1.3 Locating the defective componentAfter determining the error class by the CSS

Page 306

RX2520 M1Upgrade and Maintenance Manual Only for the Japanese market:IAlthough described in this manual, some sections do not apply to the Japanese m

Page 307 - Figure 200: Securing the TPM

50 Upgrade and Maintenance Manual RX2520 M1Basic hardware proceduresÊ Switch on the ID indicator on the front and rear connector panels of the server

Page 308

RX2520 M1Upgrade and Maintenance Manual 51Basic hardware procedures4.4 Getting access to the componentVCAUTION!●Before removing or installing covers,

Page 309 - 14.4.2 Removing the TPM

52 Upgrade and Maintenance Manual RX2520 M1Basic hardware proceduresFigure 3: Extending the server out of the rack Ê Remove all remaining external cab

Page 310

RX2520 M1Upgrade and Maintenance Manual 53Basic hardware procedures4.4.2 Removing the server from the rackIIn most cases maintenance tasks can be perf

Page 311

54 Upgrade and Maintenance Manual RX2520 M1Basic hardware proceduresWhen using a lifter, this removal procedure needs to be carried out by maintenance

Page 312

RX2520 M1Upgrade and Maintenance Manual 55Basic hardware procedures●In order to comply with applicable EMC regulations (regulations on electromagnetic

Page 313 - 14.4.3 Replacing the TPM

56 Upgrade and Maintenance Manual RX2520 M1Basic hardware procedures4.4.3.2 Removing the air ductFigure 6: Removing the air ductVCAUTION!Be careful wi

Page 314 - Figure 203: TPM spacer

RX2520 M1Upgrade and Maintenance Manual 57Basic hardware procedures4.5 Reassembling4.5.1 Installing the air ductFigure 7: Installing the air duct guid

Page 315 - 14.5 Onboard SAS enabling key

58 Upgrade and Maintenance Manual RX2520 M1Basic hardware proceduresFigure 8: Installing the air ductÊ Insert the air duct first with the rear side (1

Page 316

RX2520 M1Upgrade and Maintenance Manual 59Basic hardware procedures4.5.2.1 Mounting the housing coverFigure 9: Mounting the housing coverÊ Open the lo

Page 317

Upgrade and Maintenance Manual RX2520 M1Version historyIssue number Reason for updateReview ReviewFebruary 2014 Initial release

Page 318

60 Upgrade and Maintenance Manual RX2520 M1Basic hardware proceduresAdditionally, a lifter is required in the following cases:– The server weighs more

Page 319

RX2520 M1Upgrade and Maintenance Manual 61Basic hardware proceduresFigure 10: Mounting the server onto the rack railsÊ Fully extend the telescopic rai

Page 320

62 Upgrade and Maintenance Manual RX2520 M1Basic hardware procedures4.5.3.2 Sliding the server into the rackFigure 11: Sliding the server into the rac

Page 321

RX2520 M1Upgrade and Maintenance Manual 63Basic hardware proceduresConnecting power cords to the mainsVCAUTION!The power supply automatically adjusts

Page 322 - 14.6.1 Preliminary steps

64 Upgrade and Maintenance Manual RX2520 M1Basic hardware procedures4.7 Switching on the serverVCAUTION!●Before switching on the server, make sure the

Page 323

RX2520 M1Upgrade and Maintenance Manual 655 Basic software procedures5.1 Starting the maintenance task5.1.1 Disabling BitLocker functionalityBitLocker

Page 324

66 Upgrade and Maintenance Manual RX2520 M1Basic software proceduresIAdministrator permission required: If you are prompted for an administrator passw

Page 325

RX2520 M1Upgrade and Maintenance Manual 67Basic software proceduresÊ Under Watchdog Settings, you can obtain detailed information about the current wa

Page 326

68 Upgrade and Maintenance Manual RX2520 M1Basic software proceduresConfiguring boot watchdog settings using the iRMC web frontendÊ Enter the ServerVi

Page 327

RX2520 M1Upgrade and Maintenance Manual 69Basic software procedures5.1.3 Removing backup and optical disk mediaÊ Ask the system administrator to eject

Page 328 - 14.6.4 Concluding steps

RX2520 M1Upgrade and Maintenance ManualContents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 211.1

Page 329

70 Upgrade and Maintenance Manual RX2520 M1Basic software procedures5.1.5 Note on server maintenance in a Multipath I/O environmentWhen booting your s

Page 330

RX2520 M1Upgrade and Maintenance Manual 71Basic software proceduresDVD: Ê Switch on the server.Ê Right after switching on the server, insert the Upda

Page 331 - 15 Cables

72 Upgrade and Maintenance Manual RX2520 M1Basic software proceduresÊ Reboot the server, e.g. by pressing the reset button on the front or switching t

Page 332 - Table 8: List of used cables

RX2520 M1Upgrade and Maintenance Manual 73Basic software proceduresUsing the iRMC web frontendÊ Enter the ServerView iRMC web frontend.Ê Under System

Page 333

74 Upgrade and Maintenance Manual RX2520 M1Basic software procedures5.2.1.2 Updating or recovering the iRMCiRMC flash procedureIFor the Japanese marke

Page 334 - 15.2 Cabling plans

RX2520 M1Upgrade and Maintenance Manual 75Basic software proceduresÊ Ensure that the server has been shut down and disconnected from the mains as desc

Page 335

76 Upgrade and Maintenance Manual RX2520 M1Basic software proceduresIn order to verify whether the backup or restore process has been successful, chec

Page 336 - 15.2.2 Configuration 3

RX2520 M1Upgrade and Maintenance Manual 77Basic software procedures5.2.3 Updating RAID controller firmwareAfter replacing the RAID controller, it is e

Page 337 - 15.2.3 Configuration 4

78 Upgrade and Maintenance Manual RX2520 M1Basic software procedures5.2.4 Enabling Option ROM scanIn order to configure an expansion card that has bee

Page 338 - 15.2.4 Configuration 5

RX2520 M1Upgrade and Maintenance Manual 79Basic software procedures5.2.5 Verifying and configuring the backup software solutionIThis task only applies

Page 339

Upgrade and Maintenance Manual RX2520 M1Contents4.3 Disconnecting power cords . . . . . . . . . . . . . . . . . . 504.4 Getting acc

Page 340 - 15.2.5 Configuration 6

80 Upgrade and Maintenance Manual RX2520 M1Basic software procedures5.2.6 Resetting the boot retry counterThe boot retry counter is decremented from i

Page 341 - 15.2.6 Configuration 7

RX2520 M1Upgrade and Maintenance Manual 81Basic software proceduresResetting the boot retry counter using the ServerView Operations ManagerÊ In the Se

Page 342 - 15.2.7 Configuration 8

82 Upgrade and Maintenance Manual RX2520 M1Basic software procedures5.2.7 Enabling SVOM boot watchdog functionalityIf ServerView Operations Manager bo

Page 343 - 16 Appendix

RX2520 M1Upgrade and Maintenance Manual 83Basic software proceduresÊ Select the Advanced menu.Ê Select the status menu of the desired component:– Proc

Page 344 - 16.1.2 Server rear

84 Upgrade and Maintenance Manual RX2520 M1Basic software procedures5.2.10 Verifying the system time settingsIThis task only applies to Linux environm

Page 345 - 16.1.3 Server interior

RX2520 M1Upgrade and Maintenance Manual 85Basic software procedures5.2.11 Viewing and clearing the System Event Log (SEL)5.2.11.1 Viewing the SELYou c

Page 346 - 16.2 Configuration tables

86 Upgrade and Maintenance Manual RX2520 M1Basic software proceduresViewing the SEL using the iRMC web frontendÊ Enter the ServerView iRMC web fronten

Page 347 - 16.3.1.1 Onboard connectors

RX2520 M1Upgrade and Maintenance Manual 87Basic software proceduresIProcedures may differ depending on your Linux OS or the definition file on the cli

Page 348

88 Upgrade and Maintenance Manual RX2520 M1Basic software procedures5.2.13 Enabling BitLocker functionalityIf BitLocker Drive Encryption has been disa

Page 349

RX2520 M1Upgrade and Maintenance Manual 89Basic software procedures5.2.14 Performing a RAID array rebuildAfter replacing a hard disk drive that has be

Page 350

RX2520 M1Upgrade and Maintenance ManualContents5.2.7 Enabling SVOM boot watchdog functionality . . . . . . . . . . 825.2.8 Enabling repla

Page 351

90 Upgrade and Maintenance Manual RX2520 M1Basic software proceduresÊ Under Network Inventory, you will find detailed information on each network cont

Page 352

RX2520 M1Upgrade and Maintenance Manual 91Basic software proceduresÊ Note down the new 16-digit WWN address found under Adapter Port Name.Ê Press [Esc

Page 353 - 1 Front VGA 2 USB

92 Upgrade and Maintenance Manual RX2520 M1Basic software proceduresVCAUTION!Please note that you can only set the ATD flag. Resetting the ATD flag us

Page 354

RX2520 M1Upgrade and Maintenance Manual 93Basic software proceduresÊ If LAN teaming has been active, you will need to restore the configuration using

Page 355

94 Upgrade and Maintenance Manual RX2520 M1Basic software proceduresExecuting the fan test via the iRMC Web interfaceÊ Log into the iRMC web interface

Page 356

RX2520 M1Upgrade and Maintenance Manual 956 Power supply unitsSafety notesVCAUTION!●Do not disassemble the power supply unit. Doing so may cause elect

Page 357

96 Upgrade and Maintenance Manual RX2520 M1Power supply units6.1.1 Power supply unit configurationsFigure 14: Hot-plug power supply units: 450 W AC (1

Page 358 - 16.4 Onboard settings

RX2520 M1Upgrade and Maintenance Manual 97Power supply units6.1.3 Power supply unit slotsFigure 15: Power supply unit slots6.2 Installing hot-plug pow

Page 359

98 Upgrade and Maintenance Manual RX2520 M1Power supply units6.2.2 Removing the dummy coverFigure 16: Removing the dummy coverÊ Press in on both relea

Page 360

RX2520 M1Upgrade and Maintenance Manual 99Power supply units6.2.3 Installing a hot-plug power supply unitFigure 17: Installing the hot-plug power supp

Comments to this Manuals

No comments