63
62
ACY125Ui
ACY71-125Ui
ACY80/100Ui
A CY71/80/100/125Ui
ACY71Ui
(except
mod.ACY71Ui)
ACY71Ui ACY80Ui ACY100Ui ACY125Ui
6106 (1720-6880) 7310 (2580-8600) 8600 (4300-9632)
10750 (2580-12040)
7100 (2000-8000) 8500 (3000-10000) 10000 (5000-11200) 12500 (3000-14000)
6880 (1720-7310) 8600 (2580-9632) 9632 (4816-11352) 12040 (2580-13760)
8000 (2000-8500) 10000 (3000-11200) 11200 (5600-13200) 14000 (3000-16000)
2,75 2,7 2,63 2,98
3,29 3,6 3,61 3,33
220/2/50 220/2/50 220/2/50 220/2/50
2,58/2,43 3,15,/2,75 3,95/3,10 4,20/4,20
10 10 10 15
11,10/10,60 13,50/12,10 17,50/13,50 18,30/18,30
(O.U.) 2x4+T (O.U.) 2x4+T (O.U.) 2x4+T (O.U.) 2x4+T
3x1,5+T 3x1,5+T 3x1,5+T 3x1,5+T
670/1440 1120/2200 1120/2200 1120/2290
950/1280 1580/2020 1580/2020 1680/2140
150/30 150/30 150/30 150/30
100/30 100/30 100/30 100/30
35 43 43 44
32 41 41 42
30 39 39 40
52 53 53 54
1135 1135 1135 1135
700 700 700 700
270 270 270 270
830 900 900 900
320 330 330 330
650 830 830 1290
45/54 45/70 45/70 45/98
3/8”-5/8” 3/8”-5/8” 3/8”-5/8” 3/8”-5/8”
25/15 50/20 50/20 70/30
R410A R410A R410A R410A
10 20 20 20
0 / +43 0 / +43 0 / +43 0 / +43
-15 / +24 -15 / +24 -15 / +24 -15 / +24
Models
ACY71Ui ACY80Ui ACY100Ui ACY125Ui
INVERTER HEAT PUMP INVERTER HEAT PUMP INVERTER HEAT PUMP INVERTER HEAT PUMP
3NGF8535 3NGF8540 3NGF8545 3NGF8555
ARY24LUAN ARY30LUAN ARY36LUAN ARY45LUAN
AOY24LMAKL AOY30LMAWL AOY36LMAWL AOY45LJBYLL
1.800 2.048 2.285 2.561
Code
Logistic reference indoor unit
Logistic reference outdoor unit
Price ref.
Accessories
(see details on page 204)
SIMPLE WIRED REMOTE EXTERIOR ELECTRICAL PUMP
REMOTE CONTROLLER SENSOR HEATER CONDENSATE
3NGF... 4JAG0027 4JAG0025 4JBO0003
81 70 221 To consult
Code
Price ref.
Static pressure (Pa)
Air volume (m
3
/h)
1. Low static pressure level, mode 1 to 70 Pa
(fan speed: high).
2. Medium static pressure level, airflow at 100
Pa (fan speed: high).
Mando
Sensor temperatura
Duct Type
MODEL
Cooling capacity
kcal/h
W
Heating capacity kcal/h
W
Energy efficiency ratio (E.E.R.) Cooling
Heating
Power supply V/nº/Hz
Power consumption (Cooling/Heating) kW
Starting current A
Running current (Cooling/Heating) A
Electrical wiring
Electrical connection
Air flow processed
(min-max) Normal m
3
/h
Low m
3
/h
Static pressure (min-max) Normal Pa
Low Pa
Noise level indoor unit
(1)
High dB (A)
Medium dB (A)
Low dB (A)
Noise level outdoor unit dB (A)
Dimensions indoor unit Width mm
Depth mm
Heigth mm
Dimensions outdoor unit Width mm
Depth mm
Heigth mm
Net weight (Indoor U./Outdoor U.) kg
Pipe size Inch.
Piping lenght max. (Total/Height) m
Refrigerant type
Refrigerant charge m
Operating range Cooling ºC
Heating ºC
Remote control with thermo sensor:
this allows the temperature to be read from the remote control in a
more accurate way.
Adjustment of static pressure:
either normal-medium static pressure or low static pressure may be
chosen through the adjustment of the selector on the electronics
board.
Outside electrical heater:
the electronics board allows an external heater to be connected
(optional) to operate in heating mode while the defrosting takes place.
Tec hnical specifications
Duct Type inverter
Remote control with thermo sensor.
Static pressure regulation function.
(1) Static pressure 30 Pa
Control
Heating sensor