C150-E048-02ENM3097E+ AND M3097G+IMAGE SCANNEROPERATOR’S GUIDE
2–1CHAPTER 2 COMPONENTS2.1 Checking the Components2.2 Part Names and Functions2.3 Operator Panel FunctionsAfter unpacking image scanner, confirm that
2–22.2 Part Names and FunctionsThis section shows the exterior view of image scanner. This sectionalso provides names of each part and describes thei
2–32.2.2 Functions of each partDocument cover: Closed over and holds a document to beread.Document bed: A document to be read is placed on thebed also
2–42.3 Operator Panel FunctionsThe operator panel has indicators and a liquid crystal display screenfor displaying image scanner status. The operator
2–52.3.1 IndicatorsThe meaning of each indicator is as follows:Power indicator (Green):Lights to indicate the power is on.Ready (for reading) indicato
2–6Liquid crystal display screenThe screen has two message lines. The current read modestatus is displayed in the upper line, and messages and themod
2–7The ADF, size, density, resolution, landscape, half-tone, document,and mode 1 and 2 buttons described below are effective unless other-wise specifi
2–8Density button:Selects a density for the read operation. When this button ispressed, the lower line is displayed as shown in Screen 3. Eachtime t
2–9Landscape button:Specifies whether reading is done in landscape or portrait mode.When this button is pressed, the lower line is displayed asshown i
2–10Document button:Selects the type of document. When this button is pressed, thelower line is displayed as shown in Screen 7. Each time thisbutton
iRevised contentsFirst edditionREVISION RECORDEdition01Date publishedJan., 1996Specification No.: C150-E048-02ENThis digital apparatus does not excee
2.3.3 Buttons and liquid crystal display screen (M3097G+)Liquid crystal display screen: Displays messages only.The mode buttons have the following fu
2–12Device errorsOne of the following messages is displayed if an device errors in thescanner. If one of the following error messages is displayed, t
3–1CHAPTER 3 INSTALLATION AND CONNECTIONSPlace the scanner away from electrical noisesources and strong magnetic fields. If theimage scanner is used
3–23.2 Removing the Carrier Fixing BracketTo keep the scanner from being damaged during shipping, the carrierunit is fixed with a bracket. After plac
3–33.3 ConnectionsConnect the image scanner using the following procedure.1 Set the power switch to off.3 Connect the interface cables (for M3097E+).C
3–4(M3097G+)Connect the interface cables to the interface connectors and fasten the cableswith the catches. Connect the other ends of the cables to t
3–53.4 Mounting the StackerMount the stacker and extensions using the following procedure.1 Mount the stacker.Hook the pins on the stacker to the claw
3–6This page is intentionally left blank.
4–1CHAPTER 4 OPERATIONS4.1 Turning on the Power4.2 Reading a Document in Flatbed Mode4.3 Reading Documents in ADF ModeDocuments can be read in the fla
4–24.2 Reading a Document in Flatbed ModeThis section explains how to read a document placed on the documentbed.CAUTION!High luminance: Do not look di
iiIMPORTANT NOTE TO USERSREAD CAREFULLY ALL OF THIS MANUAL BEFORE USING THIS PRODUCT. IF NOTUSED CORRECTLY, UNEXPECTED DAMAGES MAY BE CAUSED TO THE US
4–3Landscape modePortrait modeLong sideShort side33Document bedDocument Document coverReference markOperator panelFigure 4.1 Flatbed readingDocument b
4–44.2.3 Reading a document larger than the document boardIf the size of the document is larger than the document board, read thedocument using the fo
4–54.3 Reading Documents in ADF ModeThis section explains how to read documents using the automaticdocument feeder. If the following steps are not cl
4–62 Pull up the ADF paper chute as follows:• Hold the document cover with one hand and pull up the ADFpaper chute with the other hand to unlock the A
4–74 Take documents to be placed in the ADF paper chute. Thethickness of the documents to be placed in the ADF paper chute islimited depending on the
4–86 Open the right and left guides of the ADF paper chute about 5mm wider than the document width.7 Place the documents face down onto the ADF paper
5–15.1 Removing Jammed Documents5.2 Notes on Daily Use5.3 Cleaning5.4 Replacing the Lamp Unit5.5 SCSI Address Setting (M3097G+)5.6 Replacing the Pad5.
5–25.2 Notes on Daily UseNote the following points on daily use:• The image scanner requires one to three minutes to warm up afterthe power has been t
5–35.3.2 Cleaning the ADFClean the ADF once every 5,000 pages. The cycle depends on thetypes of documents used (page quality, a level of toner fusing
5–45.3.3 Cleaning the coupled feed roller1 Pull the ADF lever up to open the ADF.2 Pull the ADF lamp replacement lever up while pushing the leverin th
iiiCONTENTSpageCHAPTER 1 PREFACE ... 1-1CHAPTER 2 COM
5–55.4 Replacing the Lamp UnitHot: Replace the lamp unit in the following procedure.If an optical alarm occurs, and the following message is displaye
5–6• Pull the ADF lever up and open the ADF.• Pull the ADF lamp replacement lever up while pushing the lever inthe direction indicated by the arrow in
5–7A2ALamp unitLamp unit leversLamp unit insertdirection (vertical)Arrows indicating the lamp unit insert position1Figure 5.6 Lamp unit replacement• O
5–8GlassLeversOpeningsFigure 5.7 Inserting the glass• Close the ADF to lock ADF lever.
5–95.5 SCSI Address Setting (M3097G+)Press the power switch while pressing the mode 1 button. The liquidcrystal display unit displays the following s
5–105.6 Replacing the pad(1) Pull up the ADF open and close lever to open the ADF.(2) Remove the four screws shown in Figure 5.8 to remove the twopads
5–115.7 Document counter display and resetThe Document counter is useful for users to check the total number ofscanned documents before regular cleani
5–12This page is intentionally left blank.
6–1CHAPTER 6 TROUBLESHOOTINGIf a problem occurs, use Table 6.1 to resolve the problem.Table 6.1 Check itemsProblemNo powerRead operationdoes not start
6–2Table 6.1 Check items (continued)ProblemThe lamp doesnot light (ready)while the powerindicator blinks.The checkindicator is on."Please clean-u
ivCHAPTER 5 MAINTENANCE ... 5-15.1 Removing Jammed Documents...
A–1APPENDIXA.1 Installation SpecificationsTable A.1 Installation specificationsSpecificationItemExternal dimensions (mm)Weight (kg)Height17325100 to 1
A–2A.2 External Dimensions173696497(Unit: mm)Figure A.1 External dimensions
FUJITSU LIMITEDInternational OperationsMarunouchi 1-6-1, Chiyoda-ku, Tokyo 100JAPANTEL: (81-3) 3216-3211FAX: (81-3) 3213-7174TLX: J22833Cable: “FUJITS
We would appreciate your comments and suggestions for improving this publication.Thank you for your interest. Please send this sheet to one of the ad
vFIGURESpageFigure 2.1 Received components ... 2-1Figure 2.2 M3097E
viTABLESpageTable 1.1 The differences between the M3097E+ and the M3097G+... 1-1Table 6.1 Check items ...
1–1CHAPTER 1 PREFACEThis manual describes how to operate the M3097E+ and M3097G+ image scanners. TheM3097E+ now supports a document counter function.
1–2This page is intentionally left blank.