Fujitsu HARD MAW3147FC User Manual

Browse online or download User Manual for Internal hard drives Fujitsu HARD MAW3147FC. Fujitsu HARD MAW3147FC User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 112
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - C141-E235-01EN

C141-E235-01EN MAW3300FC MAW3147FC MAW3073FC HARD DISK DRIVES PRODUCT/MAINTENANCE MANUAL

Page 2 - FOR SAFE OPERATION

This page is intentionally left blank.

Page 3 - C141-E235

Connector Signal Allocation A-2 C141-E235 A.1 Interface (FC-SCA) Connector Signal Allocation Table A.1 FC-SCA connector: CN1 Pin No. Signal Sig

Page 4

C141-E235 GL-1 Glossary Additonal Sense Code This is a 1-byte code displayed in the sense data and is information which specifies the type of error t

Page 5 - REVISION RECORD

Glossary GL-2 C141-E235 Target (TARG) This is the FC device that executes the input/output operations initiated by the initiator. In this manual,

Page 6 - Related Standards

C141-E235 AB-1 Acronyms and Abbreviations A ACK ACKnowledge AEN Asynchoronous Event Notification ALT ALTernated (block) ARRE Automatic Read Real

Page 7 - Preface

Acronyms and Abbreviations AB-2 C141-E235 M MR Magnetro Resistive MS Multiple Select MSG MeSsaGe O OEM Original Equipment Manufacturer P P list Pr

Page 8

C141-E235 IN-1 Index A AC noise filter ... 4-9 actuator...

Page 9 - C141-E235 iii

Index IN-2 C141-E235 format capacity ...3-8 format of extended sense data...7-2 for

Page 10

Index C141-E235 IN-3 SEND DIAGNOSTIC command... 6-3 sense data... 7-1 1-1x-xx..

Page 11 - Important Alert Items

This page is intentionally left blank.

Page 12

C141-E235-01EN Comment Form We would appreciate your comments and suggestions regarding this manual. Manual code C141-E235-01EN Manual name MAW

Page 13 - C141-E235 vii

C141-E235 v Important Alert Items Important Alert Messages The important alert messages in this manual are as follows: A hazardous situation coul

Page 14

This page is intentionally left blank.

Page 17 - CONTENTS

Important Alert Items vi C141-E235 Task Alert message Page Installation Damage 1. When dismounting the drive which is mounted on the system while p

Page 18

Important Alert Items C141-E235 vii Task Alert message Page Diagnostics and Maintenance Caution 1. Always ground yourself with a wrist strap conne

Page 19

This page is intentionally left blank.

Page 20

C141-E235 ix MANUAL ORGANIZATION PRODUCT/ MAINTENANCE MANUAL (This manual) 1. General Description 2. Specifications 3. Data Format 4. Inst

Page 21

This page is intentionally left blank.

Page 22

C141-E235 xi CONTENTS CHAPTER 1 General Description...1-1 1.1 Standard Features...

Page 23 - C141-E235 1-1

Contents xii C141-E235 4.1.2 Mounting orientations ...4-3 4.1.3 Notes on

Page 24 - 1-2 C141-E235

Contents C141-E235 xiii 6.2.5 Tools and test equipment ...6-9 6.2.6 Tests ..

Page 25 - C141-E235 1-3

C141-E235 FOR SAFE OPERATION Handling of This Manual This manual contains important information for using this product. Read thoroughly before using t

Page 26 - 1-4 C141-E235

Contents xiv C141-E235 Illustrations Figures Figure 1.1 FC model drives outer view... 1-5 Figu

Page 27 - C141-E235 1-5

Contents C141-E235 xv Tables Table 2.1 Model names and order numbers...2-1 Table 2.2 Function spec

Page 28 - 1-6 C141-E235

This page is intentionally left blank.

Page 29 - C141-E235 1-7

C141-E235 1-1 CHAPTER 1 General Description 1.1 Standard Features 1.2 Hardware Structure 1.3 System Configuration This chapter describes the f

Page 30

General Description 1-2 C141-E235 1.1 Standard Features (1) Compactness In a compact enclosure having the 3.5-inch HDD form factor, the HDD contai

Page 31 - CHAPTER 2 Specifications

1.1 Standard Features C141-E235 1-3 The continuous processing up to [64K-1] blocks in a command can be achieved, and HDD can perform continuous

Page 32 - 2-2 C141-E235

General Description 1-4 C141-E235 (12) Error recovery The HDD can try to recover from errors in Fibre Channel Loop or the disk drive using its pow

Page 33 - C141-E235 2-3

1.2 Hardware Structure C141-E235 1-5 (19) Diagnosis The HDD has a diagnostic capability which checks internal controller functions and drive opera

Page 34 - 2-4 C141-E235

General Description 1-6 C141-E235 (2) Heads The MR (Magnet - Resistive) of the CSS (contact start/stop) type heads are in contact with the disks wh

Page 35 - C141-E235 2-5

1.3 System Configuration C141-E235 1-7 1.3 System Configuration For the Fibre Channel, the ANSI standard defines Arbitrated Loop, Fabric, and Po

Page 36 - 2-6 C141-E235

C141-E235 Caution This computer device shall meet FCC Class A environment. If you use this device at Home environment, it may affect to the Televisi

Page 37 - C141-E235 2-7

This page is intentionally left blank.

Page 38

C141-E235 2-1 CHAPTER 2 Specifications 2.1 Hardware Specifications This chapter describes specifications of the HDD. 2.1 Hardware Specificati

Page 39 - CHAPTER 3 Data Format

Specifications 2-2 C141-E235 2.1.2 Function specifications Table 2.2 shows the function specifications of the HDD. Table 2.2 Function specificati

Page 40 - 3-2 C141-E235

2.1 Hardware Specifications C141-E235 2-3 (*3) The seek time is as follows: Seek time [ms] Seek Difference [4096 Cyl/div] (*4) The start ti

Page 41 - C141-E235 3-3

Specifications 2-4 C141-E235 2.1.3 Environmental specifications Table 2.3 lists environmental and power requirements. Table 2.3 Environmental/pow

Page 42 - 3-4 C141-E235

2.1 Hardware Specifications C141-E235 2-5 (*1) For detail condition, see Section 4.1. (*2) Vibration applied to the drive is measured at near t

Page 43 - C141-E235 3-5

Specifications 2-6 C141-E235 Note: The MTBF is defined as: Operating time (hours) at all field sites MTBF = The number of equipment failures fr

Page 44 - 3-6 C141-E235

2.1 Hardware Specifications C141-E235 2-7 (4) Data security at power failure Integrity of the data on the disk is guaranteed against all forms

Page 45 - C141-E235 3-7

This page is intentionally left blank.

Page 46 - 3-8 C141-E235

C141-E235 3-1 CHAPTER 3 Data Format 3.1 Data Space 3.2 Logical Data Block Addressing 3.3 Defect Management This chapter explains data space d

Page 47 - C141-E235 3-9

This page is intentionally left blank.

Page 48 - 3-10 C141-E235

Data Format 3-2 C141-E235 Note: Spare sectors on the last track in each cylinder are not necessarily placed at the end of the track because of a tr

Page 49 - C141-E235 3-11

3.1 Data Space C141-E235 3-3 (1) User space The user space is a storage area for user data. The data format on the user space (the length of data

Page 50 - 3-12 C141-E235

Data Format 3-4 C141-E235 3.1.2 Alternate spare area The alternate spare area consists of the last track of each cell in the user space and an alt

Page 51 - C141-E235 3-13

3.1 Data Space C141-E235 3-5 3.1.3 Track format (1) Physical sector allocation Figure 3.4 shows the allocation of the physical sectors in a tra

Page 52 - 3-14 C141-E235

Data Format 3-6 C141-E235 Head Track skew Track skew Head skewLeading logical sector in head p+1 Head Figure 3.5 Track skew/head skew The numbe

Page 53 - C141-E235 4-1

3.1 Data Space C141-E235 3-7 Each sector on the track consists of the following fields: (1) Gaps (G1, G2, G3) No pattern is written on the

Page 54 - 4-2 C141-E235

Data Format 3-8 C141-E235 3.1.5 Format capacity The size of the usable area for storing user data on the HDD (format capacity) varies according to

Page 55 - C141-E235 4-3

3.2 Logical Data Block Addressing C141-E235 3-9 (1) Block address of user space The logical data block address number is consecutively assigned

Page 56 - 4-4 C141-E235

Data Format 3-10 C141-E235 3.3 Defect Management 3.3.1 Defect list Information of the defect location on the disk is managed by the defect list. T

Page 57 - C141-E235 4-5

3.3 Defect Management C141-E235 3-11 (1) Alternate block allocation during FORMAT UNIT command execution When the FORMAT UNIT command is speci

Page 58 - 4-6 C141-E235

C141-E235 REVISION RECORD Edition Date published Revised contents 01 June, 2005 Specification No.: C141-E235-**EN

Page 59 - C141-E235 4-7

Data Format 3-12 C141-E235 If above errors are detected during FORMAT UNIT command, the HDD allocates the alternate block(s) to the defective data

Page 60 - 4-8 C141-E235

3.3 Defect Management C141-E235 3-13 (3) Automatic alternate block allocation • Automatic alternate block allocation at read operation If the

Page 61 - C141-E235 4-9

Data Format 3-14 C141-E235 Type 2 (Reassignment of write fail sector) 1) Commands to be applied - WRITE - WRITE EXTENDED - FORMAT UNIT - WRI

Page 62 - 4-10 C141-E235

C141-E235 4-1 CHAPTER 4 Installation Requirements 4.1 Mounting Requirements 4.2 Power Supply Requirements 4.3 Connection Requirements This ch

Page 63 - CHAPTER 5 Installation

Installation Requirements 4-2 C141-E235 The value marked with (*) indicates the dimension between mounting holes on the bottom face. [Unit: mm]

Page 64 - 5-2 C141-E235

4.1 Mounting Requirements C141-E235 4-3 4.1.2 Mounting orientations The permissible orientations of the HDD are shown in Figure 4.2, and the tol

Page 65 - C141-E235 5-3

Installation Requirements 4-4 C141-E235 (1) Mounting screw Use #6-32UNC. (2) Mounting frame structure Special attention must be given to mount t

Page 66 - 5-4 C141-E235

4.1 Mounting Requirements C141-E235 4-5 (3) Limitation of side-mounting Use the four screw holes at the both ends on the both sides as shown in

Page 67 - C141-E235 5-5

Installation Requirements 4-6 C141-E235 Table 4.1 Surface temperature check point No. Measurement point Max. temperature on package 1 DE surface

Page 68 - 5-6 C141-E235

4.1 Mounting Requirements C141-E235 4-7 (6) Service clearance area The service clearance area, or the sides which must allow access to the HDD

Page 69 - C141-E235 5-7

C141-E235 Related Standards Product specifications and functions described in this manual comply with the following ANSI (*1) standards. Document n

Page 70 - 5-8 C141-E235

Installation Requirements 4-8 C141-E235 4.2 Power Supply Requirements (1) Allowable input voltage and current The power supply input voltage mea

Page 71 - C141-E235 5-9

4.3 Connection Requirements C141-E235 4-9 (5) Noise filter To eliminate AC line noise, a noise filter should be installed at the AC input termin

Page 72 - 5-10 C141-E235

Installation Requirements 4-10 C141-E235 4.3.2 Interface connector The connector for the Fibre Channel Loop is an unshielded SCA-2 connector which

Page 73 - C141-E235 5-11

C141-E235 5-1 CHAPTER 5 Installation 5.1 Notes on Handling Drives 5.2 Setting 5.3 Mounting Drives 5.4 Checking Operation after Installation and P

Page 74 - 5-12 C141-E235

Installation 5-2 C141-E235 (2) Unpackaging a) Use a flat work area. Check that the "This Side Up" sign side is up. Handle the package on

Page 75 - C141-E235 5-13

5.2 Setting C141-E235 5-3 5.2 Setting 5.2.1 Loop ID setting When setting the fibre channel loop ID, use SEL0 to SEL6 of interface connector CN1.

Page 76 - 5-14 C141-E235

Installation 5-4 C141-E235 5.3 Mounting Drives 5.3.1 Mounting procedures Since mounting the drive depends on the system cabinet structure, determin

Page 77 - C141-E235 5-15

5.4 Checking Operation after Installation and Preparing the HDD for Use C141-E235 5-5 5.4 Checking Operation after Installation and Preparing the H

Page 78 - 5-16 C141-E235

Installation 5-6 C141-E235 The Active LED goes off while the HDD command is being executed. For some commands, however, since the Active LED goes

Page 79 - C141-E235 6-1

5.4 Checking Operation after Installation and Preparing the HDD for Use C141-E235 5-7 Motor starts when power is turned on d) Figure 5.1 Chec

Page 80 - 6-2 C141-E235

C141-E235 i Preface This manual describes the MAW3300FC, MAW3147FC, and MAW3073FC 3.5" type hard disk drives with an embedded fibre channel co

Page 81 - C141-E235 6-3

Installation 5-8 C141-E235 Motor starts by START/STOP command 1 Figure 5.2 Checking the HDD connection (B) * Executing time: about 60 seconds

Page 82 - 6-4 C141-E235

5.4 Checking Operation after Installation and Preparing the HDD for Use C141-E235 5-9 (2) Checking at abnormal end a) When sense data can be obt

Page 83 - C141-E235 6-5

Installation 5-10 C141-E235 (2) FORMAT UNIT command Initialize entire recording surface of the disk with the FORMAT UNIT command. The FORMAT UNI

Page 84 - 6-6 C141-E235

5.4 Checking Operation after Installation and Preparing the HDD for Use C141-E235 5-11 5.4.4 Setting parameters The user can specify the optimal

Page 85 - C141-E235 6-7

Installation 5-12 C141-E235 (1) Error recovery parameter The following parameters are used to control operations such as the HDD internal error r

Page 86 - 6-8 C141-E235

5.4 Checking Operation after Installation and Preparing the HDD for Use C141-E235 5-13 Notes: 1. The user can arbitrarily specify the following

Page 87 - Revising at field

Installation 5-14 C141-E235 (3) Caching parameters The following parameters are used to optimize the HDD Read-Ahead caching operations under the sy

Page 88 - 6-10 C141-E235

5.4 Checking Operation after Installation and Preparing the HDD for Use C141-E235 5-15 (4) Control mode parameters The following parameters are

Page 89 - C141-E235 6-11

Installation 5-16 C141-E235 5.5 Dismounting Drives Since the method and procedure for dismounting the disk drive for replacement of the drive, etc.

Page 90 - 6-12 C141-E235

C141-E235 6-1 CHAPTER 6 Diagnostics and Maintenance 6.1 Diagnostics 6.2 Maintenance Information 6.3 Operation Check 6.4 Troubleshooting Procedures

Page 91 - C141-E235 6-13

Preface ii C141-E235 APPENDIX A Connector Signal Allocation The appendix gives supplementary information, including the signal assignments of interf

Page 92 - 6-14 C141-E235

Diagnostics and Maintenance 6-2 C141-E235 Brief test contents of self-diagnostics are as follows. a. Hardware function test This test checks t

Page 93 - C141-E235 6-15

6.1 Diagnostics C141-E235 6-3 The HDD does not reply to the loop for up to 2 seconds after the initial self-diagnostics is started. After that, t

Page 94

Diagnostics and Maintenance 6-4 C141-E235 When an error is detected in the self-diagnostics, the HDD terminates the SEND DIAGNOSTIC command with th

Page 95 - CHAPTER 7 Error Analysis

6.2 Maintenance Information C141-E235 6-5 (1) Interface (loop) test The operations of the loop and data buffer on the HDD are checked with the WR

Page 96 - 7-2 C141-E235

Diagnostics and Maintenance 6-6 C141-E235 6.2.2 Maintenance requirements (1) Preventive maintenance Preventive maintenance is not required. (2) S

Page 97 - C141-E235 7-3

6.2 Maintenance Information C141-E235 6-7 Data loss Save data stored on the disk drive to other media before requesting repair. Fujitsu does n

Page 98 - 7-4 C141-E235

Diagnostics and Maintenance 6-8 C141-E235 6.2.4 Revision numbers The revision number of the disk drive is represented with a letter and a number in

Page 99 - C141-E235 A-1

6.2 Maintenance Information C141-E235 6-9 Revising at field When the revision number is changed after the drive is shipped from the factory, Fuji

Page 100 - A-2 C141-E235

Diagnostics and Maintenance 6-10 C141-E235 Test results OK?StartExecute an operationtest using a hostcomputer or testequipmentYesNoYesNoStart self-t

Page 101 - Glossary

6.3 Operation Check C141-E235 6-11 6.3 Operation Check 6.3.1 Initial seek operation check If an error is detected during initialization by the in

Page 102

Preface C141-E235 iii Attention Please forward any comments you may have regarding this manual. To make this manual easier for users to understan

Page 103 - Acronyms and Abbreviations

Diagnostics and Maintenance 6-12 C141-E235 6.4 Troubleshooting Procedures 6.4.1 Outline of troubleshooting procedures This section explains the tr

Page 104

6.4 Troubleshooting Procedures C141-E235 6-13 Table 6.2 System-level field troubleshooting Item Recommended work Check that the DC voltage is wi

Page 105 - C141-E235 IN-1

Diagnostics and Maintenance 6-14 C141-E235 6.4.3 Troubleshooting at the repair site For maintenance at this level, we recommend additional testing

Page 106 - IN-2 C141-E235

6.4 Troubleshooting Procedures C141-E235 6-15 6.4.4 Troubleshooting with parts replacement in the factory This manual does not cover troublesho

Page 107 - C141-E235 IN-3

This page is intentionally left blank.

Page 108

C141-E235 7-1 CHAPTER 7 Error Analysis 7.1 Error Analysis Information Collection 7.2 Sense Data Analysis This chapter explains in detail

Page 109 - Comment Form

Error Analysis 7-2 C141-E235 Bit 7 6 5 4 3 2 1 0 Byte 0 Valid X‘70’ or X‘71’ (error code) 1 X‘00’ 2 0 0 ILI 0 Sense key 3 4 5

Page 110

7.2 Sense Data Analysis C141-E235 7-3 7.2 Sense Data Analysis 7.2.1 Error information indicated with sense data Subsection 7.2.2 onwards expla

Page 111

Error Analysis 7-4 C141-E235 7.2.2 Sense data (3-0C-03), (4-40-xx), and (4-C4-xx) Sense data (3-0C-03), (4-40-xx), and (4-C4-xx) indicate one of t

Page 112

C141-E235 A-1 APPENDIX A Connector Signal Allocation A.1 Interface (FC-SCA) Connector Signal Allocation This appendix describes the connecto

Comments to this Manuals

No comments