No Item Description Selectable Default
parameters
1 Double feed check Double feed is detected by checking the
document length one by one.**
2 IPC pre-setting Scanner automatically sets the recom-
mended reading parameters. 5 sets of
recommended parameters are available.
3 Rest of abrasion Abrasion counter can be reset.
counter
4 Pick start time The time from the document Insertion to
setting the start of picking is specified. User can
select most comfortable Pick start time for
the job.
5 Time-out limit setting The time that the scanner waits for next
ducument insertion after last document
scanned can be specified.
6 ADF front offset Horizontal and vertical offset of the front
setting* side image by ADF is specified.
7 ADF back offset Horizontal and vertical offset of the back
setting* side image by ADF is specified.
8 FB offset setting* Horizontal and vertical offset of the FB
image is specified.
9 IPC/Memory status The type of IPC option (IPC-2D or IPC-3D)
display and total memory installed are displayed.
10 SCSI ID setting SCSI ID is selectable.
Tolerance: No
No/10/15/20mm
Document: No
No/1/2/3/4/5
--
Time:
0.2 to 29.8 sec
1.0 sec
Time:
27 values from 30 sec
1 to 1999 sec
Offset: Offset:
H:-2 to +3mm H: 0 mm
V:-2 to +3mm V: 0 mm
Offset: Offset:
H:-2 to +3mm H: 0 mm
V:-2 to +3mm V: 0 mm
Offset: Offset:
H:-2 to +3mm H: 0 mm
V:-2 to +3mm V: 0 mm
SCSI ID:
0/1/2/3/4/5/6/7 5