5.3.3 Mode settings
In addition to the previously described settings using setting terminals, the HDD is provided with
several mode settings. The mode settings are enabled by specifying the CHANGE DEFINITION
command. Table 5.7 lists the mode settings and their settings at factory shipment.
Refer to Subsection 3.1.4 “CHANGE DEFINITION (40)” of the SCSI Logical Interface
Specifications for details of the CHANGE DEFINITION command.
Table 5.7 Default mode settings (by CHANGE DEFINITION command)
Mode setting Contents
SCSI level SCSI-3
SYNCHRONOUS DATA TRANSFER REQUEST message
sending
Not sent from HDD
UNIT ATTENTION report mode Reported
Reselection retry count Not restricted
WIDE DATA TRANSFER REQUEST message sending Not sent from HDD
Reselection time-out delay 250 ms
0 sec (NP)
12 sec × SCSI ID (NC)
Spindle motor start delay time