Safety
Lithium-Ion Battery
Limited Power Source
Current Loading
Caution: Danger of explosion if the lithium-ion (CMOS) battery is
incorrectly replaced. Replace only with the same or equivalent type
recommended by the manufacturer. Discard used batteries according
to the manufacturers instructions.
Caution: The 24V powered USB port on the terminal does not meet
UL limited power source (LPS) requirements. This port is limited to
only allowing 24V Retail POS powered USB peripherals that do not
exceed a rated current of 4 Amps and are provided with a molded
plastic Fire Enclosure, Rated Min. 94V-1 or Metal enclosure.
Caution: The 24V powered Cash Drawer port on the terminal does
not meet UL limited power source (LPS) requirements. This port is
limited to only allowing 24V Retail POS peripherals that do not
exceed a rated current of .2 Amps and are provided with a molded
plastic Fire Enclosure, Rated Min. 94V-1 or Metal enclosure.
Caution: Powered USB ports are used for POS peripherals. The
current loading for each port is specified in the following table.
Port Ratin
g
Note
12V PUSB +12V:1.3A, +5V:0A For LCD
12V PUSB
+12V:0.4A, +5V:0A For VFD
24V PUSB
+24V:0.2A, +5V:0A For Printer
USB +5V:0.5A
USB +5V:0.5A
USB +5V:0.5A
USB (Option) +5V:0.5A
USB (Option) +5V:0.5A