5.3 Host Commands
At command issuance (I/O registers setting contents)
1F7
h
(CM) 0 0 1 1 0 1 1 1
1F6
h
(DH) 1 L 1 DV xx
1F5
h
(CH) P
1F5
h
(CH) C
1F4
h
(CL) P
1F4
h
(CL) C
1F3
h
(SN) P
1F3
h
(SN) C
SET MAX LBA (47-40)
SET MAX LBA (23-16)
SET MAX LBA (39-32)
SET MAX LBA (15-8)
SET MAX LBA (31-24)
SET MAX LBA (7-0)
1F2
h
(SC) P xx
1F2
h
(SC) C xx VV
1F1
h
(FR) P
1F1
h
(FR) C
xx
xx
C: Current
P: Previous
At command completion (I/O registers contents to be read)
1F7
h
(ST) Status information
1F6
h
(DH) 1 L 1 DV xx
1F5
h
(CH) 1
1F5
h
(CH) 0
1F4
h
(CL) 1
1F4
h
(CL) 0
1F3
h
(SN) 1
1F3
h
(SN) 0
1F2
h
(SC) 1
1F2
h
(SC) 0
1F1
h
(ER)
SET MAX LBA (47-40)
SET MAX LBA (23-16)
SET MAX LBA (39-32)
SET MAX LBA (15-8)
SET MAX LBA (31-24)
SET MAX LBA (7-0)
xx
xx
Error information
0: HOB=0
1: HOB=1
C141-E258 5-119